background image

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

D

D

E

B

E

E

A

C

P/N 0381954B

Merchandisers

®

Note: Changed items have been underlined.

Item

Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES AND

T

HERMOSTATS

A.

9W

Fan Assembly

(1)

0047000

Fan Motor, Evaporator 

0315470

Fan Blade

embossing toward motor

B.

0411744

Standard Non-adjustable

(2)

Defrost Thermostat

C.

0137880

Optional Adjustable 

(3)

Refrigeration Thermostat

Item

Part #

Description

Wiring Item #

L

AMPS AND

B

ALLASTS

D.

0376409

Ballast, Electronic

2 lamps

(4)

D.

0376410

Ballast, Electronic

3 lamps

(4)

E.

Fluorescent Lamp

(5)

Replace with like fixtures

D6

Data Sheet Set

P/N  0381954B

NSF

®

Certified

May, 2003

Summary of Contents for IMPACT D6

Page 1: ... 1 0047000 Fan Motor Evaporator 0315470 Fan Blade embossing toward motor B 0411744 Standard Non adjustable 2 Defrost Thermostat C 0137880 Optional Adjustable 3 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS D 0376409 Ballast Electronic 2 lamps 4 D 0376410 Ballast Electronic 3 lamps 4 E Fluorescent Lamp 5 Replace with like fixtures D6 Data Sheet Set P N 0381954B NSF C...

Page 2: ...rt and center support 40 5 8 1032 40 5 8 1032 Distance between edges of center supports NA 44 1118 Stub up area between front skid rail and splashguard 5 5 8 143 5 5 8 143 Electrical Service Electrical Field Wiring connection point B RH End of case to center of farthest knockout 88 3 8 2245 136 1 2 3467 Back of case to center of knockout 29 1 8 740 29 1 8 740 Length of electrical raceway 34 5 8 87...

Page 3: ...u hr ft D6 D6E LIT UNLIT SHELVES Parallel 1500 1440 Conventional 1610 1550 HUSSMANN PEG SHELVES DELI ONLY Parallel 1705 1635 Conventional 1805 1740 For all refrigeration equipment other than Hussmann use conventional Btu values DEFROST DATA Frequency Hrs 6 6 Defrost Water lb ft day 10 50 15 based on case configuration and product loading OFFTIME D6 D6E Temp Term F 48 48 Failsafe Minutes 30 35 ELEC...

Page 4: ...tandard Fans 120V 60 Hz 3 00 4 40 With Energy Efficient Fans 120V 60 Hz 1 72 2 48 With Export Fans 230V 50 Hz 1 72 2 48 Maximum Over Current Protection 120V 20 20 Export 230V 50 Hz 15 15 Electric Defrost Heaters 208V 1Φ Φ NA NA NA NA Gas Defrost Heaters 208V NA NA NA NA Standard Lighting 8 ft 12 ft 8 ft 12 ft 1 Row Canopy 0 51 0 77 59 85 Optional Lighting 1 Row Canopy and 1 Row Rail 1 02 1 54 118 ...

Page 5: ...ctor Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light Circuits BL G R 5 4 W BL R 5 BL R G G R R R G Shelf Lighting G G R BL 5 BL Connector Connector B Grayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components...

Page 6: ...models only R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Optional Lighting 3 Row Canopy 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 4 BL R R BL BL 4 5 5 5 5 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch ...

Reviews: