Owners Manual

Summary of Contents for Set & Save 47200A

Page 1: ...Model 47200A M AM 4 TEMP Programmable Thermostat Owners Manual ...

Page 2: ...ment Front access allows easy insertion of two AA 1 5V batteries Reset Press with a paper clip to reset the thermostat and return to power up settings Front Door Covers keys when not used for neat appearance Open by lifting from the bottom Up and Down Keys Keys for changing the Temperature setting Also used for increasing and decreasing selections in the Time Program and Span functions Day Time Ke...

Page 3: ...ting screws provided into wall anchor and tighten See Figure 3 NOTE 5 wire Systems If your thermostat has one wire marked R or RH 2 3 or 4 wire system then leave the jumper wire between the RH and RC terminals on the wallplate Otherwise if you have separate RH and RC wires 5 wire system then remove the jumper wire between the RH and RC terminals Connect Wires and Mount Thermostat to Wallplate Matc...

Page 4: ...oling mode NOTE HG position is for gas and most other systems HE position is for certain electric systems having a fan relay System Selector STANDARD HEAT PUMP switch The factory position for this switch is in the STD position Leave it in this position if you have ANY system that uses gas oil electric or hot water heating If you have a single stage Heat Pump no auxiliary or emergency heat source t...

Page 5: ...Time Temp Temp Temp Temp Sunday Time Time Time Time Temp Temp Temp Temp day time M PM day time M PM SA PM 2 TEMP day time hold return or SA PM 2 TEMP M F TH W T AM 1 HEAT program system cool heat off Cooling Day Program 1 Program 2 Program 3 Program 4 Monday Time Time Time Time Friday Temp Temp Temp Temp Saturday Time Time Time Time Temp Temp Temp Temp Sunday Time Time Time Time Temp Temp Temp Tem...

Page 6: ...H PM HOLD TEMP hold return Filter Monitor Your thermostat measures the number of hours your heating and cooling system has been in use To maximize your system s performance and energy efficiency change or clean your filter regularly When the total system runtime for heat and cool reaches 400 hours the Filter Change Indicator will flash as a reminder to check your system s filter Press to review to...

Page 7: ...t will automatically cut off in Heat mode if the room temperature rises above 35 C 95 F It will cut off in Cool mode if the room temperature drops below 4 C 40 F Note that if your system has malfunctioned and no longer responds to thermostat controls the Auto Cut Off will have no effect HEAT TEMP 2 TROUBLESHOOTING If you experience any other problems call 1 866 268 1936 from 8 AM to 5 PM Central T...