Installation, Operation & 

Service Manual 

Polaris Beer 
Superchiller™ 

230V / 
50Hz 

Содержание Lancer Polaris Beer Superchiller

Страница 1: ...lancerbeverage com Installation Operation Service Manual Polaris Beer Superchiller 230V 50Hz...

Страница 2: ...Location 6 6 4 Mounting Chiller 7 6 5 Connecting Python 7 6 6 Plumbing the Drain 7 6 7 Filling Unit 7 6 8 Electrical Connection 8 6 9 Commissioning 8 6 10 Purge System 8 7 Thermostat Carel Pjeasy The...

Страница 3: ...SW Melbourne VIC Brisbane QLD Perth WA and Auckland New Zealand 3 Our Products Hoshizaki Lancer specialises in the design engineering manufacture and marketing of beverage dispensing and Heat Recovery...

Страница 4: ...800 Grams R134a Tank 72 litres 72 litres 72 litres Ice bank Weight 18 kg 18 kg 18 kg Construction Stainless Steel Stainless Steel Stainless Steel 4 3 Models S4E POLARIS SPC17 Chiller with SPC17 Pump...

Страница 5: ...ution notes throughout this manual To prevent personal injury or damage to the machine these alerts must be strictly adhered too Warning Alerts to a potentially hazardous situation that if not avoided...

Страница 6: ...must be made with the carrier Upon receiving units from the delivering carrier carefully inspect shipping crate for visible indication s of damage If damage exists have carrier note damage on bill of...

Страница 7: ...l on a flat level surface using adjustable legs or casters Optional Caution Chiller operational weight is 157 179kg ensure that all supporting structures are certified for this loading by a registered...

Страница 8: ...hiller power supply lead to an appropriate 3 pin socket outlet and switch on Compressor condenser fans and pump agi motor should all operate On initial start up remove the pump plug to allow the tank...

Страница 9: ...nd DOWN keys for 5 seconds In case of probe 2 failure the antifreeze alarm function is inhibited and regulation is still performed If AF parameter is set to its minimum value the alarm function is inh...

Страница 10: ...xt parameter To exit from programming mode press the SET key for 3 seconds or wait 60 seconds without pressing any keys for the unit to time out 7 2 3 Eco Mode In the ECO mode an offset is added to th...

Страница 11: ...arm function is inhibited and regulation is still performed If AF parameter is set to its minimum value the alarm function is inhibited rt F Time in hours of max min temperatures logging rH F Highest...

Страница 12: ...lue Press the UP or DOWN key to change its value Press the SET key to store the new value and move to the next parameter To exit from programming mode press the PRG key for 5 seconds or wait 60 second...

Страница 13: ...beer system is carried out including keg couplers beer lines chiller coils pythons founts and taps 9 1 2 Monthly Disconnect the machine from the power supply Remove the condenser filter and rinse in w...

Страница 14: ...ly as product may vary 013a 25 November 2013 9 1 3 Yearly Disconnect the machine from the power supply Check interior of the tank clean product coils and evaporator if necessary to remove any accumula...

Страница 15: ...15 of 23 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000200 Images are for illustration purposes only as product may vary 013a 25 November 2013 10 Electrical C...

Страница 16: ...ge com Page 16 of 23 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000200 Images are for illustration purposes only as product may vary 013a 25 November 2013 10...

Страница 17: ...0Hz lancerbeverage com Page 17 of 23 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000200 Images are for illustration purposes only as product may vary 013a 25 N...

Страница 18: ...uate system and if necessary fit burnout drier to industry standards Compressor short cycling on thermal overload frequent starting and stopping of the compressor while control contacts remain closed...

Страница 19: ...n For both systems the liquid line probe from the Hydra control provides High Temp protection for the refrigeration system The following test is to determine if the icebank level control is operating...

Страница 20: ...433 ELECTRICAL BOX LID POLARIS 6 83000278 CONTROL LEVEL I B HYDRA R2 7a 83000184 PJ EASY OEM CONTROL KIT 7b 83000371 IR33 CONTROL KIT 8 95000642 LOUVRE KMD 0101AA 8a 95000641 FILTER 2 OF REQUIRED 9 61...

Страница 21: ...Hz lancerbeverage com Page 21 of 23 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000200 Images are for illustration purposes only as product may vary 013a 25 No...

Страница 22: ...Labour Lancer will not normally cover any labour costs associated with a warranty claim Subject to the approval of the Divisional Sales Manager Lancer may choose to reimburse the customer for some or...

Страница 23: ...lly frosts Check all tube work for rubbing e g discharge line liquid line TX capillary Condenser not touching divider panel or grille Agitator blades tight and not touching coils cradle Overflow pipe...