background image

OWNER’S GUIDE

69-0854

HR230

FRESH AIR
VENTILATION
SYSTEM

Summary of Contents for HR230

Page 1: ...OWNER S GUIDE 69 0854 HR230 FRESH AIR VENTILATION SYSTEM ...

Page 2: ...rmalde hyde tobacco by products radon moisture combustion by products and carbon monoxide With the Honeywell Fresh Air Ventilation System you can expect to enjoy the benefits of a properly ventilated energy efficient home for years to come Features and benefits Easy to clean counterflow core assures years of trouble free operation Quiet operation reduces the typical noise levels added by ventilati...

Page 3: ...VENTILATION SYSTEM 6 GETTING THE MOST FROM YOUR FRESH AIR VENTILATION SYSTEM 8 MAINTENANCE INSTRUCTIONS FOR THE FRESH AIR VENTILATION SYSTEM 9 LIMITED WARRANTY Inside Back Cover Attention Homeowner The HR230 Fresh Air Ventilation System must be maintained on a regular basis for maximum efficiency For complete instructions on maintaining your Fresh Air Ventilation System refer to the Maintenance In...

Page 4: ...reezes are just around the corner Feeling Right at Home Unlike what the outdoor brings us you can have control of indoor conditions Temperature humidity levels and air quality all can affect physical health mental attitude general comfort and energy savings With today s technological advances you can achieve a perfect climate indoors After all people look to their homes as a place to escape the st...

Page 5: ...CLIMATE COMFORT CENTER IS ONE PART OF A PERFECT CLIMATE AN INDOOR ENVIRONMENT THAT MAKES YOU FEEL BETTER ALLOWS YOU TO LIVE AND WORK MORE COMFORTABLY MAINTAINS PRECISE INDOOR TEMPERATURE HUMIDITY AND PRECISE AIR QUALITY AND ACHIEVES MAXIMUM ENERGY SAVINGS COLD AIR RETURN STALE AIR FROM BATHS M6350 How it works HONEYWELL HOME SECURITY SYSTEMS HONEYWELL PC8900 HONEYWELL W8900 1 Honeywell PC8900 Perf...

Page 6: ...emperature control Products for a Perfect Climate System Heating and cooling system This is the workhorse of your indoor climate system Good advice is to have your local heating cooling contractor tune up your system annually for comfort safety and economy reasons If your heating plant is old think about replacing it with a modern and improved unit Advances in product technology have very impressi...

Page 7: ...the ventilator runs at reduced speed 135 cubic feet per minute cfm When the switch is in the Hi position the ventilator runs at full speed 230 cfm When the switch is in the Standby position the ventilator is powered but it is not operating A signal from a dehumidistat a timer or a wall switch will cause the ventilator to run at full speed When the signal is removed the ventilator will shut off and...

Page 8: ...d times or manually by pressing the Ventilate button on the keypad See the Perfect Climate Comfort Center User s Guide form 69 0891 for complete instructions Step 4 When one or more dehumidistats are part of the control scheme set the dehumidistat at the desired humidity level Generally the dehumidistat s should be located in areas such as a bathroom that generate excess moisture When a shower is ...

Page 9: ...the previous setting when the time runs out Step 6 Your Fresh Air Ventilation System may utilize one or more wall switches to provide manual control of the system If a high ventilation rate is desired move a switch to the maximum position The ventilator will run at high speed until the switch is returned to the normal position NOTE The ventilator will run at high speed if any device in the system ...

Page 10: ...ese devices are activated the ventilator will run at the high speed The ventilator will return to the previous setting when all the remote devices are deactivated The remote override function in combination with the Standby setting is especially useful for intermittent bathroom exhaust where continuous ventilation is not required Continuous operation is recommended except when the home is unoccupi...

Page 11: ...ficiency Honeywell recommends the Fresh Air Ventilation System be cleaned and checked at least twice a year preferably at the start of each heating and cooling season Check and or Clean as Follows HEAT TRANSFER CORE AND FILTERS The room air filter fresh air filter and the heat transfer core are removed from the ventilator as a unit 1 Remove the drain hose s from the bottom of the check valve Turn ...

Page 12: ...69 0854 10 HOSE DRAIN HOSE FITTING CHECK VALVE CORE DRAIN HOLE DRAIN ACCESS HOLES ON BOTTOM OF HR230 M7610 System on à air frais Fig 2 Remove drain hose ...

Page 13: ...sliding the two catches to the left and pull the door open and off See Fig 3 DOOR TAB DOOR TAB SLOT DOOR LATCH DOOR LATCH BRACKET SLIDE DOOR LATCHES TO THE LEFT WHEN DOOR IS RELEASED PULL DOOR TABS OUT FROM SLOTS 1 1 1 2 2 2 M7604 CORE ACCESS DOOR HR230 CABINET Fig 3 Remove core access door ...

Page 14: ... by spraying it with Fantastik or a similar cleaner 7 Let the core sit for a few minutes then spray it off with a low pressure garden hose Shake the excess water out of the core before reinsert ing it into the ventilator 8 Check the interior of the ventilator for any debris that may have fallen off the filters and vacuum out as necessary 9 Reassemble the ventilator by reversing the above procedure...

Page 15: ... shall be repair or replace the product within the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WAR RANTY EXPRESSED OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT Some states do not allow the exclusion or limitation of incidental or consequential damages...

Page 16: ...yourhome Helping You Control Your World Home and Building Control Home and Building Control Honeywell Inc Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 740 Ellesmere Road Golden Valley MN 55422 Scarborough Ontario M1P 2V9 Contact Your Local Installer ...

Reviews: