background image

          HCC-96RF-C(S)  Series 

                                                                                                        HITROL  CO.,LTD.                                             

          1   

HITROL CO., LTD. 

HEAD OFFICE.FACTORY.R&D INSTITUDE 
HITROL CO., LTD 141, Palhakgol-gil, Jori-eup 
Paju-si, Gyeonggi-do, Korea   
TEL.: (00)-82-31-950-9700 
FAX: (00)-82-31-943-5600 
www.hitrol.com 

 
 
 
 

INSTRUCTION MANUAL 

CAPACITANCE TYPE LEVEL SWITCH 

HCC-96RF-C(S) Series 

 
 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Doc. no. : HCC96RFC(S)_IM_Eng_Rev.1 

Issue date: 2021. 01 

 

Summary of Contents for HCC-96RF-C Series

Page 1: ...TORY R D INSTITUDE HITROL CO LTD 141 Palhakgol gil Jori eup Paju si Gyeonggi do Korea TEL 00 82 31 950 9700 FAX 00 82 31 943 5600 www hitrol com INSTRUCTION MANUAL CAPACITANCE TYPE LEVEL SWITCH HCC 96...

Page 2: ...Contents Overview 3 Characteristics 3 Operating Principle 3 Specifications 4 Product Composition 5 Installation 6 Precautions for Installation 6 Precautions for Attachment 7 Wiring 7 Precautions for...

Page 3: ...ing from active sensing probe towards ground with reference RF signal when the medium is detecting Since all material has unique dielectric constant relative permittivity and conductance value that ar...

Page 4: ...e Entry PBT 2 PF 1 2 F IP65 Std AL 2 PF 1 2 F IP66 Opt AL 2 PF 1 2 F IP66 AL 2 PF 1 2 F IP66 Amplifier Specification Module M 96RFC M 96RFS Microprocessor 16 Bit Microprocessor Oscillation Frequency 4...

Page 5: ...Std NPT 1 PF 1 Others Flange ANSI JIS DIN Material SUS 316L Others Housing Connection Probe For HCC 96RF C Material PBT Material Aluminum Flat Type can be used in liquids but further verification is r...

Page 6: ...roof function When installing on the low level carefully install the dead stock and material bridge For outdoor installation it is recommended to install the sun cover to avoid the effects of temperat...

Page 7: ...maged while opening or closing the cover of product The grounding has an external and an internal grounding When connecting to an external ground the ground wire shall be 4 4mmSQ The internal groundin...

Page 8: ...the product Precautions for Wiring Make sure to wire contacts correctly Wire and supply the power to the product after checking the specifications Incorrect power voltage may cause damage to the prod...

Page 9: ...quest A S at our website or by contacting our headquarters Headquarters Factory Laboratory Contact Number ADDRESS HITROL CO LTD 141 Palhakgol gil Jori eup Paju si Gyeonggi do Korea T E L 031 950 9700...

Page 10: ...HCC 96RF C Setting Guide RF Admittance Type Level Switch Doc no Rev0 0 Issued Date 2020 11 18 APPENDIX Q...

Page 11: ...stment 0 1s 3 RT Relay Return Time Adjustment Time Range 0 5s 1s 10s Adjustment 0 1s 4 Fail Safe Mode Relay Transformation Adjustment N C N O 5 DET Measurement Status LED OFF Red 6 RLY Relay Status LE...

Page 12: ...r than the reference value No Function Method 1 Frequency Tuning To set the reference value while the DET LED is off adjust the TUN VR counter clockwise until the DET LED is on Fine tune TUN VR clockw...

Page 13: ...clockwise until the DET LED is off No Function Method 1 Tuning Setting Status The TUN VR state according to the Tuning Setting is the most sensitive state Keep this status for sensitive use 2 Sensitiv...

Page 14: ...y return time after undetecting the measurement No Function Method 1 DT Relay Delay Time Time Adjustment Range 0 5s 1s 10s Adjustment 0 1s No Function Method 1 RT Relay Return Time Time Adjustment Ran...

Page 15: ...1 N C Relay Contact Out Default Status After detecting the measurement the contact point changes from N C to N O LED Status No Function Method 1 N O Relay Contact Out Opposite Status After detecting t...

Page 16: ...sensor measurement status sensitivity setting value relay setting etc Monitoring Method Using PC Component PC USB Cable typical USB to Micro USB B UART Adaptor M 96RFC PC UART Component USB Cable M 9...

Page 17: ...fer to Serial USB Terminal Install Guide USB Cable M 96RFC Smartphone UART Component M 96RFC Smartphone UART Execution Open App Home Screen Select UART Connection Enter Password Run Screen Enter exit...

Page 18: ...HCC 96RF S Setting Guide RF Admittance Type Level Switch Doc no Rev0 0 Issued Date 2020 11 18 APPENDIX S...

Page 19: ...djustment 0 1s 4 RT Relay Return Time Adjustment Time Range 0 5s 1s 10s Adjustment 0 1s 5 Fail Safe Mode Relay Transformation Adjustment N C N O 6 DET Measurement Status LED OFF Red 7 RLY Relay Status...

Page 20: ...unction Method 1 Frequency Tuning Tune the cap trimmer for setting the default value Adjust clockwise until DET LED turns off 2 If the sensing LED does not turn off High capacitance in the tank Adjust...

Page 21: ...he SEN VR state according to the Tuning Setting is the most sensitive state Keep this status for sensitive use 2 Sensitivity Adjustment You can adjust the sensitivity by adjusting SEN VR Sensitivity A...

Page 22: ...ay Contact N C No Function Method 1 RT Relay Return Time Time Adjustment Range 0 5s 1s 10s Adjustment 0 1s No Function Method 1 N C Relay Contact Out Default Status After detecting the measurement the...

Page 23: ...act status to Relay Contact N O No Function Method 1 N O Relay Contact Out Opposite Status After detecting the measurement the contact point changes from N O to N C LED Status Operating Status Accordi...

Page 24: ...sensor measurement status sensitivity setting value relay setting etc Monitoring Method Using PC Component PC USB Cable typical USB to Micro USB B UART Adaptor USB Cable M 96RFS PC UART Component M 9...

Page 25: ...Adaptor App Refer to Serial USB Terminal Install Guide USB Cable M 96RFS Smartphone UART Component Open App Home Screen Select UART Connection Enter Password Run Screen Enter PW and Fly command M 96RF...

Page 26: ...Doc no Rev0 0 Issued Date 2020 04 29 Serial USB Terminal Serial USB Terminal Install Setting Guide Application Level Switch Level Transmitter APPENDIX H...

Page 27: ...B Terminal App Search and Install a App that Serial USB terminal in the App Store Serial USB Terminal Setting Run The Serial USB Terminal Icon Four types of environments must be set up for normal oper...

Page 28: ...minal Show connection message Show timestamps Setting Show connection message ON OFF Show timestamps ON OFF The size of the Terminal Font is the size set in the Smartphone Terminal Setting Terminal Fo...

Page 29: ...no Rev0 0 Issued Date 2020 04 29 Receive Newline Setting Newline CR LF Carriage Return Line Feed Check Send Newline Setting Newline Auto same as Receive CR Select Newline Default Setting Complete Defa...

Page 30: ...l echo Clear input on send Setting Local echo ON OFF Clear input on send OFF ON Local echo Setting Clear input on send Setting For detailed instructions refer to the manual of each product Select Clea...