background image

COPYRIGHT ©2019 Hangzhou Hikvision Digital Technology 

Co., Ltd. 

ALL RIGHTS RESERVED.

Any and all information, including, among others, wordings, 

pictures, graphs are the properties of Hangzhou Hikvision 

Digital Technology Co., Ltd. or its subsidiaries (hereinafter 

referred to be “Hikvision”). This user manual (hereinafter 

referred to be “the Manual”) cannot be reproduced, 

changed, translated, or distributed, partially or wholly, by 

any means, without the prior written permission of 

Hikvision. Unless otherwise stipulated, Hikvision does not 

make any warranties, guarantees or representations, 

express or implied, regarding to the Manual.

About this Manual

This Manual is applicable to Alarm Keypad.

The Manual includes instructions for using and managing 

the product. Pictures, charts, images and all other 

information hereinafter are for description and explanation 

only. The information contained in the Manual is subject to 

change, without notice, due to firmware updates or other 

reasons. Please find the latest version in the company 

website (http://overseas.hikvision.com/en/). 

Please use this user manual under the guidance of 

professionals.

 Legal Disclaimer

TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, 

THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE 

AND FIRMWARE, IS PROVIDED “AS IS”, WITH ALL FAULTS AND 

ERRORS, AND HIKVISION MAKES NO WARRANTIES, EXPRESS 

OR IMPLIED, INCLUDING WITHOUT LIMITATION, 

MERCHANTABILITY, SATISFACTORY QUALITY, FITNESS FOR A 

PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF THIRD 

PARTY. IN NO EVENT WILL HIKVISION, ITS DIRECTORS, 

OFFICERS, EMPLOYEES, OR AGENTS BE LIABLE TO YOU FOR 

ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT 

DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR 

LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR 

LOSS OF DATA OR 

                             Trademarks Acknowledgement and other 

Hikvision’s trademarks and logos are the properties of 

Hikvision in various jurisdictions. Other trademarks and 

logos mentioned below are the properties of their 

respective owners.

DOCUMENTATION, IN CONNECTION WITH THE USE OF THIS 

PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE 

POSSIBILITY OF SUCH DAMAGES.

REGARDING TO THE PRODUCT WITH INTERNET ACCESS, THE 

USE OF PRODUCT SHALL BE WHOLLY AT YOUR OWN RISKS. 

HIKVISION SHALL NOT TAKE ANY RESPONSIBILITES FOR 

ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER 

DAMAGES RESULTING FROM CYBER ATTACK, HACKER 

ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY 

RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY 

TECHNICAL SUPPORT IF REQUIRED. 

SURVEILLANCE LAWS VARY BY JURISDICTION. PLEASE CHECK 

ALL RELEVANT LAWS IN YOUR JURISDICTION BEFORE USING 

THIS PRODUCT IN ORDER TO ENSURE THAT YOUR USE 

CONFORMS THE APPLICABLE LAW. HIKVISION SHALL NOT BE 

LIABLE IN THE EVENT THAT THIS PRODUCT IS USED WITH 

ILLEGITIMATE PURPOSES. 

IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL 

AND THE APPLICABLE LAW, THE LATER PREVAILS.

Product Information

1

2

4

5

3

Wireless Alarm Keypad

This product and - if applicable - the supplied 

accessories too are marked with "CE" and comply 

therefore with the applicable harmonized European 

standards listed under the RE Directive 2014/53/EU, 

the EMC Directive 2014/30/EU, the LVD Directive 

2014/35/EU,  the RoHS Directive 2011/65/EU.

2012/19/EU (WEEE directive): Products marked 

with this symbol cannot be disposed of as unsorted 

municipal waste in the European Union. For proper 

recycling, return this product to your local supplier 

upon the purchase of equivalent new equipment, or 

dispose of it at designated collection points. For 

more information see: www.recyclethis.info

The Input voltage should meet both the SELV (Safety 

Extra Low Voltage) and the Limited Power Source 

according to the IEC60950-1 standard. Please refer 

to technical specifications for detailed information.

Tamper Screw

1

2

3

4

5

2

3

1

1

3

2

1

Control

Panel

Do not mix batteries of 

different brands.

Do not mix old and new 

batteries.

EN50131-1:2006+A2:2017

EN50131-3:2009E

N50131-5-3:2017

Security Grade 2  

Environmental Class II

Present

Beep

Tag Sensed

Present

Remove

Beep

Tag Sensed

Hold 3s, 

remove after a beep

1

2

Present

Beep

Tag Sensed

3

System

Armed

Remove

3 failed attempts 

(different unregistered 

tag or different 

password) will cause 

the keypad lock (90 s).

Refer to the 

Components 

and Indication

section for indicator and 

buzzer description.

3. Secure the mounting plate on the wall with four supplied screws.         

4. Rotate the keypad body clockwise to fasten the body on the plate.

1. Loosen the set screws on bottom of the keypad.

2. Rotate anti-clockwise to remove the mounting plate.

It is required to insert the screw for tamper alarm.

5. Tighten the screw on the bottom to fix the keypad on the mounting 

plate and complete the installation.

Enrollment

English
Diagram Reference

Specification

Components and Indication

1

3

Installation

4

5

Power On

2

Power on the security control panel. 

Make the control panel enter the 

enrollment mode. Press the tamper 

switch (on the board) of the keypad. The 

partition indicators flashes 4 times when 

the keypad is enrolled and ready for 

work. 

Note: The distance between the security 

control panel and the keypad should be 

less than 50 cm. 

1. Loosen the set screws on bottom of the keypad.

2. Remove the mounting plate.

3. Install four AA batteries according to the polarity mark.

Note: Do not reverse the polarity of the battery. 

Check Signal Strength

Enter the signal checking mode by operating on the control panel. 

Trigger the tamper alarm.

Power indicator flashes 3 times - Strong Signal 

Fault indicator flashes 3 times - Weak Signal

Buzzer

1. Indicator

2. Tag Area

3. TAMPER Switch (on the board)

Power 

IndicatorGreen

Blue

Orange

Red

Keypad Backlight White

Keypad locked: flashes 2 times

Turn off if no operation for 5 s, turn on when touched

Normal Battery: Solid green for 2s (keypad waked up) 

Low Battery:Flashing green flashes 3 times (keypad waked up)

Weak Signal Strength:Flashes 3 times

Strong Signal Strength:Flashes 3 times

Armed: Related LED flashes once, and light on 2 s while 

the keypad is waked up

Disarmed/Alarm Cleared:Related LED flashes twice

Operation failed: Related LED flashes 3 times

Alarm: Related LED flashes 30s

Enrolled and Starts work: 4 LEDs flashes 4 times together 

Patrol tag presented: Power and Fault LEDs flashes 2 times  

Patrol tag presented: Power and Fault LEDs flashes 2 times  

Zone/ Fire Alarm Triggered:Flashes 30s

No Alarm or Alarm Restored:Off

Partition 

Indicator

Fault 

Indicator

Alarm 

Indicator

Present Tag/Tap Key/Armed

Disarmed

Operation Failed

Keypad Tampered
Tag Enrolled
Zone Tampered

Fire Alarm

Beep Beep Beep

Beep Beep Beep Beep Beep

Beep

Beep

Long Beep (30 s)
Long Beep (30 s)

Beep Beep

Formatting

Remove the battery. Hold the TAMPER button (with slend rod) and power 

the keypad on at the same time. Release the button when any of the 

power, alarm, or fault indicators starts flash. The four indicators flash 4 

time after the formatting is completed.

Local Enrollment

APP Enrollment

Operation

Operation

All Partition

1. Enter the user password.

2. Tap the stay/away/disarm key.

Specified

Partition

1. Tap the user password.

2. 

Tap the √ key.

3. Enter the partition No.(1/2/3/4).

4. Tap the stay/away/disarm key.

Partition

Keypad

Fire Alarm

Panic Alarm

Confirm

Tasks

1.Enter the user password.
2.Tap the stay/away/disarm key.

Stay/Away Arming

Disarming

Global Keypad

Hold the fire alarm key for 3 s.

Hold the disarming key for 3 s.

Tap the √ key.

1

Away Arming

Other

Operation

Tag Operation

2

Stay Arming

3

Disarming

Delete

Delete the latest key operation

The buzzer indicates the operation status

3. The buzzer indicates the 

operation status

5. The buzzer indicates the 

operation status

The buzzer indicates the operation status

1. Log in to the 

APP Store. 

 Search for 

“Hik-Connect” .Download and install the 

client to your phone. Run the client.

2. Power on the security control panel.

3. Log in the client and tap the icon “+”  

to add the control panel.  Scan the QR 

code or input the device serial No. 

(serial No. is not supported by device 

with 868 RF frequency).  to add the 

device( in the registration mode).

4.  Tap the “+” icon on the device page 

to add the peripherals.

RF speed

10.0kbps

/4

.

8

kbps

RF frequency

433

.

6

MHz

/868

.0

5

MHz

RF method

2GFSK

Transmission distance

8

00m (open area)

Po

w

er

10dBm

Tamper-proof

1 tamper s

w

itch, front and rear tamper-proof

Wireless Module

Communicates 

w

ith control panel

Card reader

Supports standard IC card

Buzzer

1

Serial port

1, reserved

Indicator

3

 status indicators

:

 po

w

er (green), fault (red), and alarm (red)

4

 par

titi

on indicators

:

 armed

/

disarmed (blue)

Backlight

1 group

 

w

hite

Numeric key

10, 0 to 9

Func

ti

on key

6

re, a

w

ay arming, stay arming, diarming, dele

ti

ng, and OK

Electrical & Ba

tt

ery

Po

w

er

4

 AA Ba

tt

eries

3

V DC

,≥

 2 years standby

Opera

ti

on humidity

10

 to 90

Opera

ti

on temperature

10

 to 

+55

Color

White

/

Black

Installa

ti

on

Wall moun

ti

ng 

w

ith scre

w

s

Dimension

Diameter

:

 1

3

2 mm (

5

2

"

), Deep

:

 2

3

 mm(9

"

)

Weight

1

65

 g (

w

ithout ba

tt

ery)

Wireless Keypad

RF

Interface and

Component

Others

UD15019B

Reviews: