background image

 

 

03/20 

Model H1107.8 

Page 1 of 7 

 

 

 

 

 

1455 Kleppe Lane 

Sparks, NV 89431-6467 

(775) 359-4712 

Fax (775) 359-7424 

E-mail: 

[email protected]

 

 

website: 

www.hawsco.com

 

 

No. 0002080221 (15) 

 

 

 
 
 
 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 

 
 
 

Model H1107.8 

Water Cooler 

 

 

INSTALLATION, OPERATION 

MAINTENANCE INSTRUCTIONS 

 

LIMITED WARRANTY

 

 

HAWS warrants that this specific product is guaranteed against defective material or 
poor workmanship for a period of 

one year from date of shipment. 

HAWS liability 

under this warranty shall be discharged by furnishing without charge F.O.B. HAWS 
Factory  any  goods,  or  part  thereof,  which  shall  appear  to  the  Company  upon 
inspection to be of defective material or not of first class workmanship, provided that 
claim  is  made  in  writing  to  Haws  within    a  reasonable  period  after  receipt  of  the 
product.  Where  claims  for  defects  are  made,  the  defective  part  or  parts  shall  be 
delivered  to  the  Company,  prepaid,  for  inspection.  HAWS  will  not  be  liable  for  the 
cost of repairs, alterations or replacements, or for any expense connected therewith 
made by the owner or his agents, except upon written authority from HAWS, Sparks, 
Nevada. HAWS will not be liable for any damages caused by defective materials or 
poor workmanship, except for replacements, as provided above. Buyer agrees that 
HAWS shall not be liable for general, special, or consequential damages claimed to 
arise  under  the  contract  of  sale.  The  drinking  fountain  manufactured  by  HAWS  is 
warranted  to  function  if  installation  and  maintenance  instructions  provided  are 
adhered  to.  The  units  also  must  be  used  for  the  purpose  for  which  they  were 
intended. 

 

NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, PROVIDED 
OR GIVEN BY HAWS. 

 

CAUTION!

 Prior to making any electrical connections, verify with a voltmeter that power from the 

service panel is 

off.

 

NOTE TO INSTALLER: Please leave this information with the Maintenance Department. 
 
Haws electric water coolers are not designed or recommended for outdoor or corrosive 
environments such as enclosed chlorinated pool areas. 
Consideration must be made at the time of installation to adhere to state and/or local codes and 
environmental/atmospheric conditions such as, but not limited to, dust, corrosion, freezing, etc. 
These conditions will void the warranty. 

Summary of Contents for H1107.8

Page 1: ...e owner or his agents except upon written authority from HAWS Sparks Nevada HAWS will not be liable for any damages caused by defective materials or poor workmanship except for replacements as provided above Buyer agrees that HAWS shall not be liable for general special or consequential damages claimed to arise under the contract of sale The drinking fountain manufactured by HAWS is warranted to f...

Page 2: ...ment or mineral content is a problem an inlet filter is recommended PLUMBING CONNECTIONS Inlet is 3 8 O D push in type fitting Waste trap outlet is female 1 1 4 IPS ELECTRICAL CONNECTIONS 115VAC 60HZ 4 7 AMPS Chiller wired direct to incoming line by others PARTS LIST MODEL PACKAGE QUANTITY ITEMS INCLUDED MTGFR 7 1 Mounting Frame Required Sold Separately 3 10 Sheet Metal Screws HCR8 1 Chiller H1107...

Page 3: ...ll tubing out Tube Sizes O D Tolerance Insertion Depth 1 4 005 11 16 3 8 005 3 4 1 2 005 7 8 STEP 1 Provide wall opening as detailed in Installation Drawing Frame must be positioned such that frame flanges overlap and butt against finished wall surface Mounting holes are provided for 6 sheet metal screws After frame is positioned in wall swing chiller support tray into position See Installation Dr...

Page 4: ...t side of housing Install fittings supplied on chiller inlet and outlet tubes see Installation Drawing STEP 8 Thoroughly flush supply line to remove all foreign matter Remove the grille and connect the 1 2 IPS supply screwdriver stop not supplied to stub out in wall Place chiller on chiller support tray against right hand side fully to rear with condenser open panel side facing to front Install su...

Page 5: ...brush an air hose or a vacuum cleaner Care should be taken not to bend or deform the condenser fins STEP 3 The chiller temperature control is factory set for 50 º F water under normal conditions For colder water adjust the control clockwise For warmer water turn counterclockwise Remove front chiller panel for access to temperature control After adjustment allow unit to cycle off before checking ou...

Page 6: ...ENT IS TRUE AND CORRECT AT TIME OF PUBLICATION CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE WHEN ORDERING PARTS PLEASE SPECIFY MODEL NUMBER PART NO C FENNER 10 25 06 15 0002080221 H1107 8 N A 1 1 FV 06 26 20 DP 6 OF 7 PARTS BREAKDOWN 5545 2020 FV PBM1107 0006983506 6462 5703M 5874PBF PBA6 0005982900 HCR8 0002626550 MTGFR 7 BP7 0002981127 PART...

Page 7: ...T REMOVE SCREWS AND THEN SQUEEZE CLIPS ON NUT RETAINER TO POP OUT INSTALL IS REVERSE OF REMOVAL 7 ALIGN HOLES IN CHILLER SUPPORT TRAY WITH HOLES IN FRAME AND FASTEN WITH 10 SHEET METAL SCREWS ADULT STANDING HEIGHT WASTE 34 3 4 883mm SUPPLY 34 5 8 879mm FOUNTAIN 32 1 2 826mm BUBBLER 39 3 8 972mm FRAME 11 5 8 384mm ADULT WHEELCHAIR HEIGHT WASTE 29 1 4 743mm SUPPLY 29 1 8 740mm FOUNTAIN 27 686mm BUBB...

Reviews: