background image

 

HATO 400Y

   AUTOMATION MANUAL

FOR SLIDING GATES

WITH SLOW DOWN

 

   

                   
                                               

Summary of Contents for 400Y

Page 1: ...HATO 400Y AUTOMATION MANUAL FOR SLIDING GATES WITH SLOW DOWN...

Page 2: ...he controller uses 230Vac voltage life and health threatening All works related to the proper functioning of the device connection start up operation must be carried out in accordance with the applica...

Page 3: ...This note also applies to waste batteries and accumulators TABLE OF CONTENTS RECOMMENDATIONS AND PRECAUTIONS 2 2 IMPORTANT SAFETY INSTRUCTIONS 4 DESCRIPTION AND PRINCIPLE OF THE OPERATION OF THE CONT...

Page 4: ...r installed which automatically turns off the engine at 120 C and turns it on when the temperature drops to 85 C 5 C The applied system of rolling coding of Microchip remote controls makes the system...

Page 5: ...3 MOUNTING OF THE LIMIT SWITCH CAMS Fig 3...

Page 6: ...available to an unauthorized person CONTROLLER ADVANTAGES Soft start function increasing the life of the door Control by means of remote control transmitters up to 28 pcs On the frequency of 433 92 MH...

Page 7: ...te version of the controller DRIVER INSTALLATION Before starting the installation make sure that all safety recommendations are met Any installation work may only be performed by qualified personnel E...

Page 8: ...required greater distances 4x0 5 mm cables can be used by connecting the wires in parallel in pairs or by increasing the cross section of the cable 2x 1mm 15 SBS bell button 18 COM 1 4 Pulse generato...

Page 9: ...ning direction Otherwise swap the wires connected to the OPEN 11 and CLOSE 8 connectors after disconnecting the power supply first 7 Set potentiometer VR1 turning clockwise increases the value on the...

Page 10: ...LIGHT OFF DELAY We set it in the range from 0s to 25min with a step of 15s Default 0s If the AUTO CLOSE function is enabled set the AUTO CL switch to the OFF position Hold down the SETUP button for le...

Page 11: ...ls will shorten the auto closing time and after detecting the passage the gate will close after 5 seconds If less than 5s are left until automatic closing each detected passage will cause the countdow...

Page 12: ...ust on the VR1 potentiometer in accordance with the applicable standards Hold down the SETUP button The LED will turn on and then turn off Release the SETUP button If the gate is in the fully closed p...

Page 13: ...rol button for less than 3s or the transmitter button assigned to the SBS function or SBS The gate will start to close for work without an encoder with the power set on the VR1 potentiometer The LED w...

Page 14: ...h slowly CL Hold down the SETUP button The LED will blink 3 times Release the SETUP button The controller will return to normal operation WICKET FUNCTION It allows the door to be partially opened to t...

Page 15: ...BS sequence control button for less than 3s or the transmitter button assigned to the SBS function or SBS The gate will stop The LED will turn off Press the SBS sequence control button for less than 3...

Page 16: ...ter changing a parameter retry the learn procedure We set it in the range from 0 1s to 1s with 0 1s step Default 0 3s Przytrzymaj przycisk SETUP SETUP The LED will turn on turn off turn on and turn of...

Page 17: ...itch to the OFF position DELETING ALL TRANSMITTERS When the memory is full or we have problems with programming the transmitters we must perform the deletion procedure We recommend that you perform th...

Page 18: ...within 10 seconds Correct programming will be signaled by the LED blinking three times 2 blinks indicate full memory 1 blink means the end of the learning time After correct programming we have anothe...

Page 19: ...HEL11 8 2 2 Standby power consumption 4 5 VA Remote control type E Keeloq version HP 001 1 piece Remote control operating frequency 433 92 MHz with rolling code Min Range of the remote control in open...

Page 20: ...zed activities aimed at removing a defect in a device covered by the warranty According to the opinion of the HATO service the device or components in which material construction or production defects...

Page 21: ...n unsuccessful four times 5 The buyer is obliged to notify the seller about the defect within 2 days from the date of its disclosure 6 This warranty covers only HATO products installed and used in Pol...

Page 22: ...HATO POLSKA SP Z O O...

Page 23: ...ul Tunelowa 57 40 676 Katowice POLAND tel 032 785 25 42 www hato pl Magazyn i sprzeda ul eromskiego 1 41 205 Sosnowiec DISTROBUTOR SELLER...