background image

No.0010518181

Installation Manual of Room Air Conditioner

Read this manual before installation

1.Driver

2.Hacksaw

3.Hole core drill

4.Spanner(17,19 and 26mm)

5.Torque wrench(17mm,22mm,26mm)

6.Pipe cutter

7.Flaring tool

8.Knife

9.Nipper

12.Reamer

10.Gas leakage detector or

     soap-and-water solution

11.Measuring tape

Explain sufficiently the operating means to the user

according to this manual.

A

B
C

D

E
F

G

Optional parts for piping

Mark

Parts name

Non-adhesive tape

Adhesive tape

Saddle(L.S) with screws

Connecting electric cable

for indoor and outdoor

Drain hose

Heating insulating material

Piping hole cover

Arrangement of piping directions

Rear left

Rear

right

Left

Below

Right

The marks from     to     in the figure are the parts numbers.

The distance between the indoor unit and the floor should be

more than 2m.

A

G

Attention must be paid to

the rising up of drain hose

mc

na

ht 

er

o

m

m

c

0

1

 

n

a

h

e

r

o

m

m

c

0

1

 

n

a

h

e

r

o

m

A

C

No.

Accessory parts

Remote controller

R-03 dry battery

Mounting plate

Drain hose

Steel nail, cement

Screw

Plastic cap

Drain-elbow

Cover

Cushion

1

1

2

3

4

5

6

7

8

9

10

2

1

1

6

4

1

1

4

1

Number

    of

articles

Accessory parts

4X50

4X25

Pipe supporting plate

11

Connecting cable

1

m

c

0

1

 

n

a

h

e

r

o

m

m

c

0

6

 

n

a

h

e

r

o

m

m

c

5

1

 

n

a

h

e

r

o

m

m

c

0

1

 

n

a

h

e

r

o

m

D

E

Note:Cooling only units don't have Drain-elbow

Drawing for the installation of indoor and outdoor units

Necessary Tools for Installation

Summary of Contents for 10518181

Page 1: ...piping directions Rear left Rear right Left Below Right The marks from to in the figure are the parts numbers The distance between the indoor unit and the floor should be more than 2m A G Attention must be paid to the rising up of drain hose m c 5 n a h t e r o m m c 0 1 n a h t e r o m m c 0 1 n a h t e r o m A C No Accessory parts Remote controller R 03 dry battery Mounting plate Drain hose Stee...

Page 2: ...ft In the case of fixing the remote controller on a wall place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened Place which is less affected by rain or direct sunlight and is sufficiently ventilated Place possible to bear the unit where vibration and noise are not increased Place where discharged wind and noise do not cause a nuisance to the neighbors ...

Page 3: ...rticle When the mounting plate is first fixed for the position of wall hole Fix to side bar and lintel a mounting bar Which is separately sold and then fasten the plate to the fixed mounting bar Make a hole of 60 mm in diameter slightly descending to outside the wall Install piping hole cover and seal it off with putty after installation Section of wall hole Piping hole pipe Outdoor side Thickness...

Page 4: ...e body aslant from the underside and then put it down perpendicularly 1 Insert the drain hose into the dent of heat insulation materials of indoor unit 2 Insert the indoor outdoor electric cable from backside of indoor unit and pull it out on the front side then connect them 3 Coat the flaring seal face with refrigerant oil and connect pipes Cover the connection part with heat insulation materials...

Page 5: ...sten the connected cable with the wiring cover Note When connecting the cable confirm the terminal number of indoor and outdoor units carefully If wiring is not correct proper operation can not be carried out and will cause defect 5 A breaker should be incorporated into fixed wiring The breaker should be all pole switch and the distance between its two contacts should be not less than 3mm Connecti...

Page 6: ... wiring is not correct proper operation can not be carried out and controller may be damaged If the drain elbow is used please attach it as figure Note Only for heat pump unit Drawing for the installation of indoor and outdoor units Insert the cable according to terminal number in the same manner as the indoor unit Fix the cable with a clamp Half union Flare nut Spanner Torque wrench 6 Outdoor uni...

Page 7: ... rod Valve cap 7 9 20 25 Tighten torque N m When connecting pipe exceeds 5 meters 20g refrigerant shall be added per exceeding meter Charge according to the following list Piping length Additional amount 5m 7m No need 40g During this procedure 50g refrigerant will be discharged in piping This must be strictly controlled within 90o and 10 sec Brand new outdoor unit is charged 50g more refrigerant t...

Page 8: ...n pan of the indoor unit and confirm that drainage is carried out surely to outdoor In case that the attached drain hose is in a room please apply heat insulation to it without fail Please kindly explain to our customers how to operate through the instruction manual Gas leak from pipe connecting Heat insulation of pipe connecting Are the connecting wirings of indoor and outdoor firmly inserted to ...