background image

1

6E 6023.g

6E 6023.g

A

5

B
C

D

EG400

EG002

5

1 x

1 x

1 x

4 x

1 x

1 x

7 x

1 x

2 x

1 x

1 x

1 x

1 x

2 x

1 x

5 x

A

5

B
C

D

2 x

auto

selection
of mode

enter the date

enter the time

The programming is made digit after digit.
The digit to be altered flashes and can be altered
by key 

.

To select the following digit, press key 

, to 

choose the previous digit press key 

.

When there is no longer a digit flashing, the data
input is completed.

To set up a programme, it is possible to make a
grouping of days and channel.
Thus, a setting common to several days and 
several channels will count as one programme step.

Note : after resetting or energising the timer 
the display will appear after 10 seconds.

A
B
C

D

3

3

A
B
C

D

1

A
B
C

D

3 4

A
B
C

D

A
B
C

D

3

A
B
C

D

A
B
C

D

3

3

A
B
C

D

3

A
B
C

D

3

A
B
C

D

3

A
B
C

D

3

A
B
C

D

A
B
C

D

3

3

1 x

1 x

1 x

1 x

1 x

1 x

1 x

1 x

1 x

4 x

2 x

9 x

1X

prg

A
B
C

D

3

1 x

A
B
C

D

A
B
C

D

3

3

1 x

1 x

Presentation

The EG400 programmer consists of 9 keys on
the front :

• 

for the selection of the different modes :

The select mode is shown by a marker
at the top of the display panel.

CI :

- for cancelling date while programming
- for cancelling completely the memory

in mode 

(press twice when the

number of free programme steps appears).

A B C D :

For permanent settings or settings with
automatic return of the different channels
- permanent settings : press the key of

the selected channel continuously for 3
seconds (shown by the indication 

perm

)

- settings with automatic return by

pressing briefly the closen channel

according of the mode : modification

of the digit, allocation of days, choice
of function 

1X

or choice of channel 

status (on 

, off 

or pulse

)

selection of following digit

selection of preceding digit

A

B

C

D

CI

A
B
C

D

3

5

2

1

7

4

6

auto

1X

prg

date

prg

Pg1...Pg15

date

- set time

- weekly programming   

Prg

- on or off setting for a given period

Date

- visual display

- automatic   

Auto

- instruction, modification or cancellation

of summer/winter timetable changes

- definition of weekly override programmes

Pg1... Pg15

Set time mode

selection
of mode

selection of
channel A

selection of 
channel status

enter the day

enter the time

To alter the time or date :
- select the set time mode, using key 
- select the digit to be changed by using the 

or 

keys, alter by using 

- then return to automatic mode by using 

(press as many times as necessary).

Programming the basic weekly cycle.
This mode contains several programming possibilities :
1 - a setting is assigned to one day and one

channel

2 - a setting is common to several days (group

of days) and one channel.

3 - a setting is common to several days (group

of days) and different channels.

4 - a setting applies once only for a given day

(mode 

1X

).

A programme in memory can be changed by
addition, modification or removal of a setting 
(the view mode also allows these changes)

1 - a setting is assigned to one day and one

channel

ex : Wednesday (3) at 19. 00 switch on channel A

Programming mode   Prg

The programmer can be radio synchronised
via the EG001 aerial. So the time and day
setting, the winter / summer time change will
be made automatically.

This mode enables the time and date to be set
example : date 27.05.2000

time : 20.15

reset button : before commencing to

programme press this button ; this button (left of
button A), sets date and time to zero.
The programme can be cleared from memory
by pressing the 

CI 

button.

return to
automatic mode

- back up program saved in the programmer 

- loading of the programmer with the

program contained in the key

The programme step is enabled ; enter the next
step or return to automatic mode or any other
mode by using 

.

The programme step is enabled ; enter the next
step or return to automatic mode or any other
mode by using 

.

The programme step is enabled ; enter the next
step or return to automatic mode or any other
mode by using 

.

1

prg

3

A
B
C

D

5 6

3

A
B
C

D

5 6

3

A
B
C

D

5 6

3

A
B
C

D

5 6

3

A
B
C

D

5

3

A
B
C

D

4

3

A
B
C

D

A
B
C

D

3

A
B
C

D

5 6 7

A
B
C

D

3

3

3

3

5 6

5 6

5 6

A
B
C

D

5 6

A
B
C

D

A
B
C

D

3

3 x

2 x

4 x

9 x

1 x

1 x

1 x

1 x

1 x

1 x

1 x

2 x

2 - a setting is common to several days (group
of days) and one channel.

ex : Wednesdays (3), Fridays (5) and Saturdays

(6) at 19. 00 switch off channel B

3

5

2

1

7

4

6

A
B
C

D

3

5

2

1

7

4

6

A
B
C

D

3

5

2

1

7

4

6

A
B
C

D

3

5

2

1

7

4

6

A
B
C

D

3

5

2

1

7

4

6

A
B
C

D

3

5

2

1

7

4

6

A
B
C

D

3

5

2

1

7

4

6

A
B
C

D

3

5

2

1

7

4

6

A
B
C

D

3

5

2

1

7

4

6

A
B
C

D

3

5

2

1

7

4

6

A
B
C

D

3

5

2

1

7

4

6

A
B
C

D

3

5

2

1

7

4

6

A
B
C

D

3

5

2

1

7

4

6

A
B
C

D

3

5

2

1

7

4

6

A
B
C

D

1 x

1 x

6 x

1 x

3 x

1 x

5 x

2 x

1 x

1 x

3 x

2 x

3 x

1 x

3 - a setting is common to several days (group
of days) and different channels.

ex : every day of the week at 16. 35 switch on
channel B, 30 second pulse for channel C.

The programme step is enabled ; enter the
next step or return to automatic mode or any
other mode by using 

.

5

A
B
C

D

5

A
B
C

D

5

A
B
C

D

5

A
B
C

D

5

A
B
C

D

5

A
B
C

D

5

A
B
C

D

1 x

1 x

1 x

2 x

3 x

2 x

2 x

1X

1X

4 - a setting applies once only for a given day “

1X

once used, the programme step is cleared
from the memory
ex : on Friday (5) next, at 20. 00, switch on
channel C.

selection
of mode

selection of
channel B

selection of 
channel status

enter the group
of days

enter the time

after about 3 sec., return to automatic mode.

selection of
channel C

selection of 
channel C status

enter length of
pulse

selection of 
channel B status

selection of
channel C

selection of
function 

1X

selection of 
channel C 
status

after about 3 sec., return to automatic mode.

after about 3 sec., return to automatic mode.

after about 3 sec., return to automatic mode.

after about 3 sec., return to automatic mode.

On / Off settings
mode for a given period

A
B
C

D

A
B
C

D

A
B
C

D

A
B
C

D

date

1 x

1 x

5 x

3 x

3 x

3 x

2 x

3 x

1 x

3 x

selection
of mode

selection 
of channel

enter channel
status

date of start
of period

date of end
of period

3

5

2

1

7

4

6

A
B
C

D

3

5

2

1

7

4

6

A
B
C

D

1

prg

A
B
C

D

7 x

1 x

selection
of mode

5

A
B
C

D

5 6

A
B
C

D

5

A
B
C

D

1

prg

A
B
C

D

1 x

4 x

2 x

selection
of mode

enter the day

ex : from 15.01 to 30.04 channel B continuously
switched on.

The period is enabled ; enter the next period
or return to automatic mode or any other mode
by using 

.

When choosing mode 

1X

, the setting will be

erased once it has passed and will not be
repeated the following year.

enter the time

enter the group
of days

enter the time

GB

User instructions

4 channel programmer annual
and weekly cycle with
programming key

NC

D

ATÉ

du 10/02/2010

selection of
channel B

http://waterheatertimer.org/Hagar-timers-and-manuals.html