background image

Page 1 of 8

Model:

MPPT30-1L

Unit 2, 110 Station Road, Seven Hills ,NSW,  2147, Australia

Operating Instructions

Please read these instructions before use

This revolutionary maximum power point tracker solar charger was 

designed using the technology that won GSL Electronics the prestigious 

“2008 EDN Innovation award”. A simple, compact and low cost 

alternative. Ideal for charging 

12V / 28V / 58V  

LiFePO

4

 

batteries with the 

new low cost and high efficiency grid type panels. 

MPPT30-1L Unit

1700W Solar Battery Charger

Maximum Power Point Tracker

MPPT30-1L-R3

PATENT APPLIED FOR - 2010901565

Summary of Contents for MPPT30-1L

Page 1: ... tracker solar charger was designed using the technology that won GSL Electronics the prestigious 2008 EDN Innovation award A simple compact and low cost alternative Ideal for charging 12V 28V 58V LiFePO 4 batteries with the new low cost and high efficiency grid type panels MPPT30 1L Unit 1700W Solar Battery Charger Maximum Power Point Tracker MPPT30 1L R3 PATENT APPLIED FOR 2010901565 ...

Page 2: ...ation Voltage Default 14 6V 29 2V 58 4V High Capacity Option 14 8V 29 6V 59 2V Long Life Option 14 3V 28 6V 57 2V Maintenance Voltage 14 1V 28 2V 56 4V Output power 1700W 30A MAX Quiescent current 0 05A Thermal protection Multilevel Type Dimensions mm 185 X 145 X 67mm Indications LED display OUTPUT STATUS Basic Wiring Instructions MPPT30 1L R3 Disconnected Connected Panel Panel Battery Battery Opt...

Page 3: ...table Important Notes To enhance Battery and Load protection the MIHV or equivalent and a suitable BMS rated to the maximum panel power and 170 of nominal battery voltage is highly recommended Use only PV Systems with open circuit voltage below 95V and a VMP of 18V for 12V Charging 36V for 24V Charging and 72V for 48V charging This equipment must be installed by qualified personnel only and incorr...

Page 4: ... 42 32 63 48 84 64 42 32 84 64 Grid Connect Panel size no cells in grid 1x18 Cell Grid 10 8 1x48 Cell Grid 28 23 2x48 Cell Grid 56 46 3x48 Cell Grid 84 69 1x52 Cell Grid 31 25 2x52 Cell Grid 62 50 3x52 Cell Grid 93 75 1x54 Cell Grid 32 26 2x54 Cell Grid 64 52 3x54 Cell Grid 96 78 1x60 Cell Grid 36 29 2x60 Cell Grid 72 58 1x72 Cell Grid 44 36 2x72 Cell Grid 88 72 1x96cgsp 65 55 For optimal performa...

Page 5: ... 2 Remove 7 front panel screws and the front panel and slide out cover see Figure 1 3 Locate connector J4 By default this will be Jumperless Nominal Setting see Figure 1 4 Shift link on J4 to desired battery setting High Capacity see Figure 2 Long Life See Figure 3 5 Slide back cover and fit in front panel carefully ensuring led is still visible through the faceplate and screw back the 7 mounting ...

Page 6: ...ructions Please read these instructions before use MPPT30 1L R3 Unit 2 110 Station Road Seven Hills NSW 2147 Australia 1700W Solar Battery Charger Maximum Power Point Tracker Figure 2 Above High Capacity Setting Figure 3 Above Long Life Setting ...

Page 7: ...ts of loads can I power with the MPPT30 1 The maximum bulk charge current with the MPPT30 1 on a 12V battery and 400W panel is approximately 30A so you can expect about 100AH per day which means a 100W load for about 10 hours daily 2 Following the same reasoning with a 24V 800W panel the MPPT30 1 will supply a daily load of 200W for about 10 hours 3 Following the same reasoning with a 48V 1600W pa...

Page 8: ...e MPPTs current gain available In principle at 25C it is possible to achieve 30 gain but at 40C a more realistic average temperature about 20 is still available Q What happens at low PV currents The MPPT will outperform the conventional regulator above 3 of nominal panel power Below 3 about 10W in a 400W panel the MPPT will have a slightly lower output current than a non MPPT MPPT30 1L R3 Warranty...