background image

 

 

 

 

 

 

GPS WRISTWATCH TRACKER 

GW-2000 

  User’s Manual 

(V

2

2

2

2.0

.0

.0

.0

 

 

 

s

ss

s

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for GW-2000

Page 1: ...GPS WRISTWATCH TRACKER GW 2000 User s Manual V2 2 2 2 0 0 0 0 s s s s ...

Page 2: ...Maintenance and Repair 5 Chapter 2 General Introduction 6 2 1 Appearance 6 2 2 Functions 6 2 3 Hardware 6 2 4 Appearance Introduction 7 Chapter 3 Accessories 8 3 1 Desktop battery charger 1 8 3 2 Charger cable 1 8 3 3 Earphone 1 8 3 4 Batteries 2 8 Chapter 4 Product Definition 9 4 1 Interface Definition 9 Chapter 5 Before use 10 5 1 Charging 10 5 2 Buy the SIM Card 10 5 3 Insert the SIM card 10 Ch...

Page 3: ...battery for 2 3 times for not less than 12 hours each time so as to ensure the battery in good condition Please charge the battery with the charger provided by our company All damages due to the use of any other charger are on the user s account Don t drop the batteries in fire for fear of burning or explosion of the batteries Don t put any stress on the batteries during battery installation or th...

Page 4: ...nd the charger are not waterproof don t use them in a highly wet place such as a bathroom or in the rain Only the maintenance personnel specially trained by our company are allowed to repair the product Any unauthorized disassembly or repair on this product might disable the warranty or lead to damage to this product 1 2 6 Network Service As the function realization of the product depends on the m...

Page 5: ...time 1 4 Maintenance and Repair Don t dismantle any part of the system for fear of malfunction If there is any problem please turn to the local agent or after service center Don t put the mainframe directly in the sun dampness dust or heat When it is used at the edge of normal temperature its normal operation will be affected but that does not mean any failure or error Just take it easy Avoid abno...

Page 6: ... Low power alarm SOS Emergency Alarm GPS timing function 2 3 Hardware Charging voltage 110 220V Working temperature 20 65 Humidity 5 95 Limited working temperature 30 C 40 C 80 C 85 C Storing temperature 45 C 90 C Start up time hot start 1 5s Warm start 34s Cold start 35s Autonomous Accurate positioning 3 0 m 2D RMS DGPS 2 5 m Speed Positioning 0 1m s DGPS 0 05m s Power consumption standby 48mA De...

Page 7: ...t green button is used to turn on off the device the lower left blue button is the mode interface shifting key the upper right button is the emergency dial SOS key and the central right button and the lower right key are dial keys See Figure 2 Figure 2 Power on off Earphone Charger Mode SOS Phone 1 Phone 2 ...

Page 8: ...GW 2000 Wristwatch Tracker 8 Chapter 3 Accessories 3 1 Desktop battery charger 1 Figure 3 3 2 Charger cable 1 Figure 4 3 3 Earphone 1 Figure 5 3 4 Batteries 2 Figure 6 ...

Page 9: ...on The upper left Signal 1 on the latitude and longitude interface is GSM signal indication The upper left Signal 2 on the latitude and longitude interface is GPS signal indication Push the Shift key to shift between the analogue clock interface and the digital clock as shown below ...

Page 10: ... icon will keep flashing Remarks If the device is idle for a long time the batteries in it might be of lower power than the initial power Then it will take a few minutes to charge the batteries to resume the normal condition Low Cell When the battery power is almost used up during normal operation or when the device is turned on the terminal will give out the low cell alarm After a while the termi...

Page 11: ...the device and enter the main interface 6 2 2 Turn Off Hold on to Key 1 to turn off the device 6 2 3 Interface Shift Push Key 2 to shift 6 2 4 Emergency Alarm Push Key 4 for emergency alarm operation and the interface indication will be Then the watch will dial the three phone numbers preset in it in turn For more information about the setting method seethe appendix If the first phone number is go...

Page 12: ...n the phone is got through the watch will enter the call interface Remarks For more information about the setting of the emergency alarm call and the Call 2 and Call 3 commands please refer to the appendix 6 2 6 Calling and Auto answer If there is an incoming call on the terminal the interface will be Then push the SOS key to get through the call If the call is not got through manually it will be ...

Page 13: ... tracker receives the SMS and confirms the password correctly it switches to the SMS application mode After the success it will send the confirmation messages SET MODE OK CURRENT MODE SMS P2P to the sender 1 2 Set up the password instruction Format 777 new password 4 figures old password 4 figures eg 77712340000 Explanation Confirm the password correctly changes the new password to the old passwor...

Page 14: ...uction Format 666 password 4 figures eg 6660000 Explanation When GW2000 tracker receives the instruction and confirms the password correctly reads the GPS information No matter whether effective the information with the replying base station which is the set of the original software will be sent to the sender Data format Lat Latitude Direction Latitude Value Accuracy for 5 after the decimal point ...

Page 15: ... V ID IMEI 353686009002030 STATE SMS If in the cold start and GPS no position it will return to the void of information ERROR GPS GPRMC FRAME DATA BS 27971054 1 5 Send the positional information in fixed time instruction Format 4 xx password 4 figures eg 4010000 Explanation x indicates one figure from 0 to 9 while xx 60 its unit is minute while xx 60 its numerical value is xx minus 60 and unit is ...

Page 16: ... configuration reset After factory set or reset timing upload is stop 1 6 Telephone localization function Explanation One of 3 telephone numbers stored in advance calls in and hangs up after ringing 2 5 times then the GW2000 will send the location information in form of 1 4 to this number the information state item automatically updates STATE CALL 1 7 Seeking help initiatively When press the key m...

Page 17: ...t will send confirmation message time zone Eastern Western xx For example Set 8960000E08 instruction GW2000 screen time for GPS time plus 8 set 8960000W07 instruction GW2000 screen time for GPS time minus 7 Note GW2000 displayed on the screen the initial time GPS time ie Greenwich Mean Time 1 10 Point to Point inquiry Format 123 Description When the GW2000 receives the instruction and confirm the ...

Page 18: ...Explanation When GW2000 tracker receives the instruction and confirms the password correctly changes the user name to the new user name After the success it will send the confirmation messages to the sender The content is CHANGE USERNAME OK 2 3 Change the service password Format 802 password new service password old service password eg 802 0000 1111 0000 Explanation When GW2000 tracker receives th...

Page 19: ...mat 2 the content is SET GPRS ACCOUNT OK 2 5 Set up the TCP IP server and IP s address and port number Format 804 password fixed IP address port eg 804 0000 222 125 12 32 80 Explanation When GW2000 tracker receives the instruction and confirms the password correctly updates the IP address and port number preserved in the module After the success it will send the confirmation messages to the sender...

Page 20: ...ch time at least is 10 at most is 80 When GW2000 tracker receives the instruction and confirms the password correctly sends the confirmation messages to the sender The content is SET GPS SAMPLING TIME AND QUANTITY OK At the same time as specified in the instructions to the sampling interval time continuous read the GPS data and preserve to the memory block When the memory block reaches to the numb...

Page 21: ...he first user telephone number If it is unsuccessful closed or unable to connect or no response makes vibration and starts calling the second and the third in turn 2 10 Function of answering and ending calls active calls automatic answer end Note When one of the stored phone numbers of calls come in the user can take the initiative to press SOS button or automatically after ringing 10 seconds to a...

Page 22: ...r in two modes 777 new password old password Change password in two modes 801 password new user name Change the user name in GPRS mode 802 password new service password old service password Change service password in GPRS mode 803 password APN Set up access GPRS points in GPRS mode 804 password fixed IP port Set up TCP IP server s IP address and port number in GPRS mode 805 password interval the n...

Reviews: