GS-SR103 System Installation Guide 

1-i 

 

 
 
 
 

GS-SR103 

 
 
 

Rackmount Server 

System Installation Guide 

 

 
 
 
 
 
 
 

 

 

Summary of Contents for GS-SR103

Page 1: ...GS SR103 System Installation Guide 1 i GS SR103 Rackmount Server System Installation Guide ...

Page 2: ...ON CARD INSTALLATION 4 3 4 6 AIRFLOW DUCT INSTALLATION 4 4 4 7 REINSTALL TOP COVER 4 6 4 8 DOCK HANDLES INSTALLATION 4 6 4 9 HARD DISK DRIVE INSTALLATION 4 7 4 10 APPEARANCE OF GS SR103 4 8 4 10 1 FRONT VIEW OF THE GS SR103 4 8 4 10 2 REAR VIEW OF THE GS SR103 4 8 4 10 3 LED INDICATOR 4 9 4 11 CONNECTOR ICONS 4 10 The author assumes no responsibility for any errors or omissions that may appear in ...

Page 3: ...ounding should be in accordance with local and national electrical codes The equipment operates safely when it is used in accordance with its marked electrical ratings and product usage instructions Do not use this product near water or a heat source Set up the product on a stable work surface or so as to ensure stability of the system Openings in the case are provided for ventilation Do not block...

Page 4: ...ing a lightning storm There may be a risk of electrical shock from lightning To reduce the risk of fire use only No 26 AWG or larger telecommunications line cord Do not plug a modem or telephone cable into the network interface controller NIC receptacle Disconnect the modem cable before opening a product enclosure touching or installing internal components or touching an uninsulated modem cable or...

Page 5: ...s with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation FCC part 68 applicable to products fitted with USA modems The modem complies with Part 68 of the FCC Rules On this equipment is a label that contains am...

Page 6: ...ceptable method of connection The customer should be aware that compliance with the above conditions might not prevent degradation of service in some situations Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications...

Page 7: ...relating to electro magnetic compatibility R TTE Directive applicable to products fitted with European modems This modem does not require any physical and or software additional switch settings from the User and is suitable for use only on telephone lines provided with Multi Frequency Dialing facilities The equipment has been approved in accordance with Council Decision 99 5 EC on radio equipment ...

Page 8: ......

Page 9: ...n to the following tips Go through the installation guide carefully before starting the system installation processes Keep the system away from static and magnetic field Do not apply any cleaning solutions directly to the system 2 2 Features The Gigabyte GS SR103 is an ultra thin rack optimized server that offers superior performance and scalability to your networking system It contains the severa...

Page 10: ... ON OFF control AMI BIOS with enhanced ACPI feature for PC99 Win98 Win2000 compliance Green PnP DMI INT 13 8 4GB Anti Virus functions Auto detect report system health status Chipset VIA Apollo Pro Family AGP set VT82C694X VT82C686A Chipset ATI Rage XL VGA Chip PROMISE PDC20265R Intel 82559 Dual LAN chip Memory Supported 4 168 pin 25 degree slant DIMM sockets Supports PC 100 PC 133 SDRAM and VCM SD...

Page 11: ...y the contents If any component is missing or damaged in the system please contact your vendor immediately 3 1 Component Content List System Chassis Power Supply installed GA 6ETXDR Motherboard installed Slim type CD ROM drive installed Slim type Floppy drive installed Three Hard Disk Drive Trays for GS SR103 The CPU heat sinks Two Dock Handles with two screws Driver Application CD Installation Ma...

Page 12: ......

Page 13: ...mbscrews from the back of the system Fig 1 Step 2 Standing at the front of the system Gently apply force to the indentures with your thumbs and push toward the rear of the chassis for about 3 4 of an inch Top cover may be lifted straight up Fig 2 Figure 1 Figure 2 Step 3 After removing the top cover you will see a plastic air duct over the CPU and Memory Remove the air duct to install the CPU and ...

Page 14: ...nal position Fig 4 Fig 5 Figure 4 Figure 5 4 3 Heat Sink Installation Step 1 Click in the Heat sink into the CPU socket 370 Step 2 Seat the heat sink firmly in the retention modules by press down the heat sink clip Follow the arrow direction shown in Fig 6 Figure 6 4 4 Memory Installation The motherboard contains four slanted DIMM Dual Inline Memory Module sockets The system BIOS will auto detect ...

Page 15: ... one expansion raiser slot for a peripheral card 64Bit 66 MHz full length To install the peripheral please go through the following steps Step 1 There are two screws holding the raiser bracket First remove the screw on the top of the bracket then remove another screws located at the rear of the server Fig 8 Fig 9 Figure 8 Figure 9 Step 2 Carefully remove the PCI raiser bracket Fig 10 ...

Page 16: ...operly into PCI slot Fig 13 4 6 Airflow Duct Installation GS SR103 is installed a new device which called Airflow Duct The main function of Airflow duct is the capability of driving out excessive system heat Especially the CPU Heat In order to maintain the system operation smoothly please note that CPU and RAM have been installed Remember to apply the airflow duct back onto the system to ensure th...

Page 17: ...m operation To install the airflow duct properly please take the following steps Step 1 Please insert the Airflow Duct follow the arrow direction Fig 14 Figure 14 Step 2 After smoothly insert the Airflow Duct please pay attention to the stable clip circle on Fig 15 Ensure the airflow duct is firmly inserted in the Airflow Stable Rack Figure 15 Figure 16 Step 3 Fig 16 indicates Airflow Duct should ...

Page 18: ...lation of the entire essential components from subsection 4 1 to 4 6 replace the plastic air duct This will secure the airflow is inside the chassis Failure to do so may cause CPU and Memory over heat Figure 17 Replace the top cover insuring that the thumbscrews are tightened Fig 17 4 8 Dock Handles Installation Remove the dock handles from the package Put two on each side of the chassis secure wi...

Page 19: ...he chassis Fig 19 Insert the hard disk drive into the tray Secure each hard disk drive with screws Fig 20 Figure 19 Figure 20 Step 2 After securing the hard disk drive with the screws hold the hard drive handle at open position place the tray into chassis Fig 21 and push the hard disk drive tray handle to the closed position Fig 22 Figure 21 Figure 22 ...

Page 20: ... 10 Appearance of GS SR103 4 10 1 Front View of the GS SR103 4 10 2 Rear View of the GS SR103 CD ROM Drive Serial Port Floppy Drive USB LED Power Connector Expansion Slot 1 IDE ATA 100 Easy swap HDD 2 IDE ATA 100 Hot Swap HDD support RAID 0 1 ...

Page 21: ...acting On Amber Fan fail Fan LED Off N A Fan acting System LED N A No definition HDD Power LED Acting Color Status HDD LED 1 Off N A No HDD Installed HDD LED 1 On Green HDD Installed HDD LED 2 Off N A HDD idle HDD LED 2 Blink Green HDD acting HDD LED 2 On Amber HDD fail HDD LED 2 Blink Amber HDD RAID rebuild HDD LED1 HDD LED2 Power LED USB Connectors LAN 1 LED LAN 2 LED Fan Status LED System Statu...

Page 22: ...GS SR103 System Installation Guide 4 10 4 11 Connector Icons Suggested icons Description Keyboard VGA Mouse LAN ParallelPort Serial Port USB ...