background image

Geosignal 

 

 

 

 

Dataloggers 
XP 101K USB

 

Version 1.0.1
User Manual

Summary of Contents for XP 101K USB

Page 1: ...Geosignal Dataloggers XP 101K USB Version 1 0 1 User Manual...

Page 2: ...Geosignal XP 101K USB Data Logger Copyright 2018 all rights reserved www geosignal com au 2...

Page 3: ...tents INTRODUCTION 4 GETTING STARTED 6 MEMORY STRUCTURE 13 CALIBRATION 17 TROUBLESHOOTING 20 TECHNICAL SPECIFICATIONS 21 Geosignal XP 101K USB Data Logger Copyright 2018 all rights reserved www geosig...

Page 4: ...versampling resolution Double calibration for maximum precision Multiple starts with separate timestamps for each sampling section Text file output compatible with common software like Open Office and...

Page 5: ...e named DATALOGS CSV The data logger will start scan at the given time with the given scan rate after it will be detached from the USB socket Geosignal XP 101K USB Data Logger Copyright 2017 2018 all...

Page 6: ...tall one before using the logger We have tested Notepad on Windows Gedit on Ubuntu and Ted on Android 4 0 Please note that some Android devices have no host capability others do not immediately open U...

Page 7: ...50 Bar 0000 Bt50 Edit values save file to program them Do not change position length of fields Detach and plug device to show actual programmed values Log starts at Start Time after device is detached...

Page 8: ...OL TXT Please NOTE we have found that after the data logger has been connected to a USB socket all the different operating systems we have tested read the file just ONCE CONTROL TEXT IS CASE SENSITIVE...

Page 9: ...h a separate command please see the below millisecond scan rate paragraph Downloading Data Connect the data logger to any USB socket of a computer If the logger shows SCAN RATE pgm that indicates it i...

Page 10: ...by the data logger when it is inserted into the USB socket The charge percentage is shown as Bt 99 in the file CONTROL TXT and it is worked out from the battery voltage which may not reflect the real...

Page 11: ...tton located at the top of the USB plug inside the logger After that the file CONTROL TXT of the data logger will show that the current time has been reset and needs to be reprogrammed Geosignal XP 10...

Page 12: ...010 00 PSI 0000 and saving the CONTROL TXT The data logger will restart Close and reopen the file CONTROL TXT it will show SENSOR 145 04 PSI 0000 Millisecond Scan Rate The datalogger can scan at fast...

Page 13: ...ns the data If it is empty its length is zero CLAIBRAT TXT show the calibration constants and other parameters CONTROL TXT once opened with a text editor like notepad will appear as follow GEOSIGNAL U...

Page 14: ...ou to unmount the data logger UNIX command or to go through the process of Safely remove the drive before the data is actually programmed into the data logger The data logger features a red LED to inf...

Page 15: ...the starting time is past and not being used CLOCK 000 indicates the clock calibration in or seconds per week and can be changed to adjust the internal clock if it is running fast or slow SENSOR 050 0...

Page 16: ...rks the measurement units BAR in this case The values of an existing file are automatically converted in PSI when the logger is set to operate in PSI All fields are separated by a comma and the period...

Page 17: ...hown because of calculation and errors the logger cannot measure negative values depression To compensate for zero and gain errors XP 101K can be programmed with the following The offset calibration c...

Page 18: ...o shows the equivalent values in term of pressure when applicable Calculating Offset and Scale Please note that the offset does not correspond to the output of the instrument at zero pressure as the s...

Page 19: ...eed of scale calibration a ratio smaller than 1 000 indicates that the gain needs to be lowered a ratio greater than 1 000 indicates that the gain needs to be increased For Example analysing some data...

Page 20: ...make sure device is unmounted or Safely removed Datalogger is connected but an error is produced when downloading data file Erase memory Measures downloaded are inconsistent Change the operating rang...

Page 21: ...pling interval 1 500msec 1 sec 10 sec 1 min 10 min 1 hour 1 day Software No Not required Operating Temp C 40 85 C excluding battery Compensated Temperature C Type A 0 C to 50 C Type B 0 C to 55 C Medi...

Page 22: ...K A 250 PSI 17 2 BAR XP 101K B range ranges 100 PSI 6 88 BAR 250 PSI 17 2 BAR 1000 PSI 68 8 BAR 5000 PSI 344 BAR 10000 PSI 688 BAR Geosignal XP 101K USB Data Logger Copyright 2017 2018 all rights rese...

Page 23: ...ising 6 Introduction 4 LED 8 Macintosh Users 6 Memory Structure 13 Millisecond Scan Rate 12 15 Negative pressure 17 Offset 15 17 Order Code 22 Programming 8 Read inputs in real time 12 Reset 11 Scale...

Page 24: ...Geosignal TM www geosignal com www geosignal com au support geosignal com PO BOX 2418 Warwick WA 6024 Australia...