INSTALLATION 

MANUAL

SMARTEC PLUS

Electronic 90˚ Basin Tap      

PLUS1000 (M/B/BM) - Polished

PLUS1000S (M/B/BM) - Satin

Electronic Wall Mounted Tap   

PLUS2500 (M/B/BM) - Polished

PLUS2500S (M/B/BM) - Satin

Summary of Contents for SMARTEC PLUS

Page 1: ...INSTALLATION MANUAL SMARTEC PLUS Electronic 90 Basin Tap PLUS1000 M B BM Polished PLUS1000S M B BM Satin Electronic Wall Mounted Tap PLUS2500 M B BM Polished PLUS2500S M B BM Satin ...

Page 2: ...ct Features 3 Product Range 4 Technical Drawings 5 Unit components 6 General Connections 8 Sensitivity Adjustment 10 Electronic Basin Tap Installation 11 Electronic Wall Mounted Tap Installation 12 Product Warranty 14 ...

Page 3: ... efficient 6 Star WELS rated Smartec Plus range utilises laminar flow technology eliminating the risk of aerosol creation where traditional aerators are used When combined with the factory set Hygiene Flush programming the Smartec Plus range presents as an optimum solution for improved health and hygiene within facilities Infection control features Factory set Hygiene Flush programming available u...

Page 4: ...4 Foroptimum operationallife the installation ofa PRVset to 350kPa is recommended Product Range PLUS1000 M B BM ELECTRONIC 90 BASIN TAP PLUS2500 M B BM ELECTRONIC WALL MOUNTED TAP ...

Page 5: ...4 3 3 2 2 1 1 B F A E D C B PLUS1000BM Smartec Plus Steven Penson SCALE 1 2 APPROVED BY PRODUCT RANGE A4 LAST UPDATE 02 03 20 Electronic Single Temperature Bench Mounted Tap 6 20 28 Ricketty St Mascot NSW 2020 www gentecaustralia com au info gentecaustralia com au This drawing is property of Gentec Australia Pty Ltd All dimensions are in mm unless specified PRODUCT CODE AND DESCRIPTION MAR LD PLUS0...

Page 6: ...6 Foroptimum operationallife the installation ofa PRVset to 350kPa is recommended Spare Parts Breakdown DIAGRAM 1 PLUS1000BM DIAGRAM 2 PLUS2500BM ...

Page 7: ...Flexible Hose 1 06 Sensor 1 07 Temperature Probe No Description Qty 01 Tap Body 1 02 Aerator Housing Cover 1 03 Aerator 1 04 Hex Screws 2 05 Spout Flange 1 06 Mounting Screws 4 07 Wall Plugs 4 08 Back Nut 1 09 Threaded Piece 1 10 Sensors 1 11 Grub Screw 1 12 Flange 1 TABLE 1 PLUS1000BM TABLE 2 PLUS2500BM OPERATION REQUIREMENTS Water Pressure Minimum 50kPa Optimum 350kPa Maximum 450kPa Temperature ...

Page 8: ...attery Operated M Mains Operated Screw the solenoid box to the wall using the screws provided Ensure to have enough space between the wall and the fixing point FOR ALL UNITS PLUS1000BM PLUS2500BM When using the unit for the first time Make sure to turn the power on first and then the water flow Lines must be flushed before installation ...

Page 9: ...e of the sensor When you remove your hands out of range water should stop within 2 seconds The maximum duration of continuous flow is 1 minute BATTERY CHANGE 1 In case you have plugged in the mains disconnect power and open the cover of the control box open the battery holder remove the batteries and replace all batteries with new ones 2 Please install the batteries in the right direction the and ...

Page 10: ...Immediately place your finger on the sensor until the light becomes solid This allows the sensor to enter in reprogramming mode 4 Place your hand to the desired position to adjust sensitivity and hold it in position until the light turns off 5 To set the sensor at maximum distance disconnect the power cable from the solenoid box and repeat step 3 to enter in reprogramming mode Do not place anythin...

Page 11: ...nstructions 3 Place the Flange and insert the sensor cable followed by the flexi hose through the tap hole in the counter top 4 From underneath the sink or basin fix rubber seal fixing plate and fixing nut with a spanner Make sure the screws are well tightened to the counter top 5 Plug in sensor to solenoid box See page 8 for complete installation of Solenoid Mounting Nut Washer Important Informat...

Page 12: ...net hole 4 Fasten the tap to the hob using the 4 fixing screws 5 Slide over the cover flange and secure with single screw provided Note For instructions on connecting the sensor to the solenoid please refer to page 14 HOB FIT OUT ELECTRONIC WALL MOUNTED TAP PLUS2500BM Important Information Switch power on solenoid box first and test electronics before turning on water supply Wall Plugs PRIOR TO IN...

Page 13: ... the threaded piece into the female plumbing fitting in the wall Use the 2 flats to tighten with correct spanner 5 Feed the sensor wires through the conduit and push the tap body through the threaded piece 6 Use the Spout flange to mark out the 4 mounting screw holes 7 Fix the screws and tighten 8 Slide over the cover flange and secure with single screw provided SENSORS INSTALLATION 1 Connect the ...

Page 14: ...mpleted credit card authorisation in the form set out in Schedule 2 to these conditions accepting liability in accordance with clause 2 6 if the product is not faulty 2 3 The Principal will on receipt of a notice in accordance with clause 2 2 issue a case number for the investigation of the alleged defective Goods 2 4 In the event that the Goods are to be returned to the Principal You may bring or...

Page 15: ...ent permitted by law the Principal 4 2 1 excludes all implied warranties and conditions under statute or general law as to merchantability description quality suitability fitness for purpose or otherwise 4 2 2 is not liable for loss of profit indirect consequential or incidental loss damage or injury in connection with the Goods 4 2 3 is not liable for the labour costs associated with replacing th...

Page 16: ...5pm on a Business Day in which case that communication will be deemed to have been received at 9am on the next Business Day 5 2 3 if emailed at the local time in a place of receipt of that email which then equates to the then time at which the email is sent as shown on the transmission report which is produced by the computer from which that email is sent and which confirms transmission of that em...