background image

SAVE THIS MANUAL FOR FUTURE REFERENCE

Register your Generac product at:

WWW.GENERAC.COM

1-888-GENERAC

(1-888-436-3722)

Owner’s Manual

Generac PWRcell™ Inverter

009954

(000209b)

WARNING

Loss of life. This product is not intended to 
be used in a critical life support application. 
Failure to adhere to this warning could result 
in death or serious injury.

Register your Generac product at:

https://register.generac.com/

1-888-GENERAC

(888-436-3722)

Para español, visita: 

http://www.generac.com/service-support/product-support-lookup

Pour le français, visiter: 

http://www.generac.com/service-support/product-support-lookup

Summary of Contents for PWRcell X11400 Series

Page 1: ...product is not intended to be used in a critical life support application Failure to adhere to this warning could result in death or serious injury Register your Generac product at https register generac com 1 888 GENERAC 888 436 3722 Para español visita http www generac com service support product support lookup Pour le français visiter http www generac com service support product support lookup ...

Page 2: ...ge See Serial Number Locations When contacting an Independent Authorized Service Dealer IASD or Generac Customer Service always supply the complete model number and serial number of the unit Table 1 Generac PWRcell Inverter Important Information Unit Model Number Unit Serial Number Date Purchased Commissioning Date 000393a WARNING CANCER AND REPRODUCTIVE HARM www P65Warnings ca gov ...

Page 3: ...Control Panel 7 LED Indicators 7 REbus Status LED 7 Inverter LED 7 Safety Shutdown LED 7 Internet LED 7 Operational Modes Overview 8 Grid Tie 8 Clean Backup 8 Priority Backup 9 Self Supply 9 Self Supply Setpoints 10 Section 3 Operation Operation and User Interface 11 Home Screen 11 Selecting Operational Modes 11 Device Pages 12 Enabling and Disabling Devices 12 Mod Settings Menu 13 Ethernet Config...

Page 4: ...iv Owner s Manual for Generac PWRcell Inverter This page intentionally left blank ...

Page 5: ... this manual and on tags and decals affixed to the unit are not all inclusive If using a procedure work method or operating technique that the manufacturer does not spe cifically recommend verify that it is safe for others and does not render the equipment unsafe Throughout this publication and on tags and decals affixed to the unit DANGER WARNING CAUTION and NOTE blocks are used to alert personne...

Page 6: ... damage 000182a WARNING Equipment damage Only qualified service personnel may install operate and maintain this equipment Failure to follow proper installation requirements could result in death serious injury and equipment or property damage Connecting Generac PWRcell to the electric utility grid must only be done after receiving prior approval from the utility company Only competent qualified pe...

Page 7: ...y Safety Shutdown 000600 DANGER Electrocution Initiate a system wide safety shutdown and turn PWRcell Disconnect Switch OFF on all connected batteries before performing service Failure to do so will result in death serious injury equipment and property damage NOTE A loss of grid power will not de energize REbus in a system configured to island or provide backup power See Figure 1 1 Shutdown button...

Page 8: ...Introduction and Safety 4 Owner s Manual for Generac PWRCell Inverter This page intentionally left blank ...

Page 9: ...rent nanogrid A 30 Maximum input source backfeed current to input source nanogrid A 30 Output power factor rating ac 1 Operating Voltage range ac 2ph V rms 108 130 Operating Voltage range ac 3ph V rms 106 132 Operating frequency range or single frequency Hz 59 6 60 4 Nominal output voltage ac V rms 120 240 208 3 ph Normal output frequency ac Hz 60 Maximum continuous output current ac A rms 32 Maxi...

Page 10: ...ac PWRcell Inverters disconnect from the grid and provide AC power to support protected loads when configured to do so All Generac PWRcell products use the REbus 380 VDC nanogrid to connect energy sources storage and loads The REbus nanogrid automates the flow of power to enable plug and play setup and operation of Generac PWRcell equipment For more information about REbus visit www generac com In...

Page 11: ...grid itself See display A for more information about the specific fault detected Inverter LED Inverter LED D communicates the status of the utility grid and or inverter through LED color and state Green utility is connected and within normal operational voltage and frequency Blinking green system is in standby mode powering up or initializing Yellow utility grid is not within normal conditions but...

Page 12: ...charged using only solar power Clean Backup Net metering solar energy without a battery Grid Tie Use grid as little as possible Self Supply Never sell power to grid Zero Export Grid Tie In Grid Tie mode the Generac PWRcell Inverter functions as a conventional grid tied inverter system The system powers local loads and when generation exceeds load demand excess power is exported to the utility for ...

Page 13: ... drawn from the grid and the amount of power being consumed by local loads before reaching the battery 009959 Figure 2 9 Priority Backup 1 of 2 See Figure 2 10 In the event of grid failure the inverter enters Islanding mode Protected loads are supported by solar and battery power If enough solar power is available the solar simultaneously charges the battery and supports the loads 009961 Figure 2 ...

Page 14: ...attery and solar power is available to cover the load then the grid will supply the additional power 0 W TargMinImprtP Target Minimum Import Power Use this setpoint to charge the battery from the grid If the overall building load is less than this setpoint the inverter will import power to the battery to keep the grid import power up to the setpoint If the building load is above the setpoint the i...

Page 15: ... consumed animated arrows indicate the flow and direction of power System AC and DC voltage levels are displayed near the center of the screen The current operational mode is displayed at the top of the screen 009965 Figure 3 2 Home Screen Selecting Operational Modes Once a system is installed an operational mode that best suits the user s needs must be set Once set the system remains in that mode...

Page 16: ...600 DANGER Electrocution Initiate a system wide safety shutdown and turn PWRcell Disconnect Switch OFF on all connected batteries before performing service Failure to do so will result in death serious injury equipment and property damage 000627 DANGER Electrocution Never enable any device during an installation or while wires are exposed Doing so could result in death serious injury equipment or ...

Page 17: ...verter device settings To access user adjustable parameters 1 Use the left and right arrows to navigate to the desired device page 2 See Figure 3 11 Highlight Mod Settings and press the center button to select 010234 Figure 3 11 Internet Device Page NOTE After selecting Mod Settings it may take a moment for the settings to load 3 See Figure 3 12 Use the up and down arrows to scroll through availab...

Page 18: ...on Serial Number and Registration NOTE Registering an inverter automatically registers all REbus system components connected to that inverter Every REbus enabled device can be monitored from the PWRview online monitoring system and mobile app To register a system for PWRview monitoring 1 See Figure 3 15 Locate the serial number and registration code on the registration decal on the front of the in...

Page 19: ...eplaceable parts Maintenance Periodically check the intake filter on the bottom of the enclosure to ensure it is not clogged with dust See Component Locations for intake filter location Clean the filter with a soft brush or vacuum cleaner Clean the exterior of the enclosure with a soft cloth Recovery From an Error State Error events will force the Generac PWRcell Inverter into an error state where...

Page 20: ...16 Owner s Manual for Generac PWRCell Inverter Maintenance This page intentionally left blank ...

Page 21: ...Owner s Manual for Generac PWRcell Inverter 17 Maintenance This page intentionally left blank ...

Page 22: ...18 Owner s Manual for Generac PWRCell Inverter Maintenance This page intentionally left blank ...

Page 23: ......

Page 24: ...ights reserved Specifications are subject to change without notice No reproduction allowed in any form without prior written consent from Generac Power Systems Inc Generac Power Systems Inc S45 W29290 Hwy 59 Waukesha WI 53189 1 888 GENERAC 1 888 436 3722 www generac com ...

Reviews: