Instruction manual

HHD revision: 1.0x
Manual P/N: 1601-9096-A1
GE publication code: GEK-113540
Copyright © 2009 GE Multilin

IISO9001:2000

GE

M ULTILI

N

RE

GISTERED

*1601-9096-A1*

HandHeld Display (HHD)

Summary of Contents for HandHeld Display

Page 1: ...gy Multilin GE Multilin 215 Anderson Avenue Markham Ontario Canada L6E 1B3 Tel 905 294 6222 Fax 905 201 2098 Internet http www GEmultilin com Instruction manual HHD revision 1 0x Manual P N 1601 9096 A1 GE publication code GEK 113540 Copyright 2009 GE Multilin IISO9001 2000 G E M ULTILI N R E GISTERE D 1601 9096 A1 HandHeld Display HHD ...

Page 2: ... and FlexLogic are registered trademarks of GE Multilin Inc The contents of this manual are the property of GE Multilin Inc This documentation is furnished on license and may not be reproduced in whole or in part without the permission of GE Multilin The content of this manual is for informational use only and is subject to change without notice Part number 1601 9096 A1 September 2009 ...

Page 3: ...tors 5 2 HHD graphical display pages 6 Home display page 7 Default display 8 Actual values pages 8 Status pages 9 Setpoints pages 11 Diagnostics pages 12 Control page 13 Popup windows 13 3 MM300 MM200 programming techniques using the HHD 15 Enumeration setpoints 15 Numeric setpoints 16 Alphanumeric setpoints 17 Date time and IP entry 17 Security access 18 ...

Page 4: ...toc ii HANDHELD DISPLAY INSTRUCTION MANUAL ...

Page 5: ...se The unit also includes industrial strength magnets that allow the HHD to be temporarily mounted on the LV MCC while accessing the relay 1 1 Introduction to the HHD The central feature of the HHD is a 3 5 inch 320 by 240 pixel backlit color LCD screen The panel also contains keys pushbuttons that control the display and perform commands In addition the interface contains START A START B and STOP...

Page 6: ... the time is replaced with the text TEST MODE in red The soft key labels are indicated on the bottom line The soft keys are used for navigation performing functions and for acknowledgement Navigation soft keys can be used to traverse across and down the hierarchy of pages Functional soft keys can be used to perform page specific functions Acknowledgement soft keys can be used to acknowledge popup ...

Page 7: ...s to all sub pages and also contains a status and process values summary Double pressing the HOME key recalls the default display Like a screen saver the default display appears after a period of inactivity and displays user selected information A typical default display is shown below indicating a running motor in the forward direction Figure 3 Typical default display actual size The UP and DOWN ...

Page 8: ...ode entry For example pressing and holding the ENTER key or attempting a control where a password is required displays the following page Figure 4 Passcode entry dialog box The ESC key functions in different ways depending on its context If a pop up dialog box is displayed the ESC key closes it If an edit sequence is in progress the ESC key cancels the edit If a field is selected the ESC key de se...

Page 9: ...ble parameters The LED colors can be independently configured by the user to display either red orange or green as required by local operating conventions The following LEDs are available for the HHD Running LED Indicates that the motor is running It will be on whenever the contactor A or B relays are closed and the contactor status inputs acknowledge the correct state Current flow does not affect...

Page 10: ...he HHD 853701A3 CDR Amps Power Volts Sensor Values Inputs Outputs System Message Flex Summary Status Reset Protection Control Security Config Setpoints CT VT Inputs Outputs Motor Comms System Events Counters Thermal Mech Elec Sensor Starter Inhibits Interlock UV Restart Alarms Trips Control Counters Phasors Info Events Learned Diag Clear Clear Manual Auto Control Main menu Level 1 Level 2 Level 3 ...

Page 11: ... tripped blocked stopped pre contactor starting running status and inhibit Motor load thermal capacity used and power Estimated time to trip if motor is loaded above its service factor 8883701A1 CDR Amps Sensor Values Inputs Outputs System Message Summary Status Reset Protection Control Security Config Setpoints CT Inputs Outputs Motor Comms System Counters Thermal Mech Elec Sensor Starter Inhibit...

Page 12: ...es returns directly to the home page 2 2 Default display The default display is automatically shown when no control key has been pressed for five minutes It can also be recalled at any time by double clicking the HOME key The default display can be set to the home page any actual values page or any status page A page can be set to be the default display by navigating to that page and double pressi...

Page 13: ... the HHD provide the user with up to date information on the current status of the MM300 or MM200 Status pages are divided into five sections for the MM300 and 4 sections for the MM200 Message displays all locked out conditions plus conditions such as alarms internal faults control status etc Inputs displays the present state of assigned contact inputs Outputs displays the present state of assigne...

Page 14: ... key items such as FLA CT Type starter type and control Source that must be configured before the unit will be available for use Protection values must still be configured for the motor to be protected correctly Inhibits These include Process Interlock Stop and Field Stop Trips Alarms These trigger depending on the protection setpoints A typical example would be Overload Trip Information Messages ...

Page 15: ...s change is made and it is clear the relay is performing as intended with the new setpoints Figure 13 setpoints home page To streamline the setpoint entry process the HHD will not display setpoints that are not relevant at the specific instance For instance if a process interlock function is disabled the six setpoints associated with that interlock function will not be displayed If all ten process...

Page 16: ... for up to 256 events Counters accumulated system counter data Phasors MM300 only metered phasor data Info product information Learned learned values based upon metered data Typical diagnostic pages for phasors MM300 and product information are shown below Figure 15 Typical phasors page MM300 Figure 16 Typical events page MM300 Pressing ENTER on the highlighted line line 9 above will take you dire...

Page 17: ... enabled Figure 18 Typical control page display Refer to the Control section for details on control page functionality 2 8 Popup windows There are three types of popup windows Setpoint editor popup windows Help popup windows Invalid operation popup windows Refer to the Setpoints chapter for details on setpoint editor popup windows Help popup windows are initiated by pressing the HELP key This will...

Page 18: ...or uninstalled options for example accessing the undervoltage restart page when undervoltage restart option is not ordered Where a keypress is illegal because a security passcode is required the popup is a passcode entry dialog box Figure 20 Typical invalid operation popup window Help and illegal action popup windows remain open until they are acknowledged by clicking any soft or hard key or until...

Page 19: ...ettings select from a limited set of values for example enabled or disabled The following procedure describes how to edit an enumeration setting 1 Use the soft keys to select the relevant setting page 2 Use the UP and DOWN keys to select the relevant setting field 3 Press the ENTER key A popup window will appear with a list of available values 4 Use the UP and DOWN keys to select from the availabl...

Page 20: ...at can be disabled In order to activate the functions offered by these buttons the user has to highlight the appropriate button and press Select The UP and DOWN front panel keys can also be used to increment and decrement the setpoint by its step value Clicking the ENTER key verifies the displayed value If the setpoint value is valid it is stored as the new setpoint value and the editor is closed ...

Page 21: ...ores the selected value while pressing ESC cancels the editing sequence and closes the popup editor The following procedure describes how to edit an alphanumeric setting 1 Use the soft keys to select the relevant setting page 2 Use the arrow soft keys to select the relevant alphanumeric setpoint field 3 Press the ENTER key to open the alphanumeric setpoint editor 4 The first character of the alpha...

Page 22: ... lockout reset and firmware download When there are no pop ups present a sustained press on the ESC key clears the security passcode When operations are performed that require a higher level of security a passcode entry dialog box automatically opens for example in entering factory page at read only security access Figure 25 Password entry dialog box The encrypted key information appears only when...