Page 1: ...tomation co uk US tel 1 603 742 9181 Europe tel 44 0 1438 833577 LSM TU4 Family Application Notes from v7 5 0 Contents Page Features 1 Configuring programmable heights 2 Controlling the Mechanism 4 User operation 4 Programming Mode 5 ...

Page 2: ... store programmable heights you must first enter programming mode In programming mode the lift then the telescope will move sequentially a Press STORE STORE PRESET to enter programming mode b IMPORTANT The mechanism will start to move out as soon as STORE STORE PRESET has been keyed in c Once in programming mode the lift will move fully out followed by the telescope Once this has happened the IN a...

Page 3: ...scope extensions a There are 3 intermediate positions available accessed by the A B and C commands b Position the telescope at the required intermediate position c Press STORE A to set the current position as position A d Press STORE B to set the current position as position B e Press STORE C to set the current position as position C f The programmed position can be verified in programming mode at...

Page 4: ... seconds User operation IR RS232 CC Pin see note below Action Comments IN fa_in Pin 8 or Pin 5 short removed Mechanism fully in OUT fa_out Pin 7 or Pin 5 shorted Raise to full extension Raises to out switch if no maximum extension is configured HOME fa_home Lift raised with the telescope retracted A fa_a Lift raised with the telescope at intermediate position A B fa_b Lift raised with the telescop...

Page 5: ...e IR RS232 CC Pin see note below Action Comments STORE STORE PRESET Enter programming mode STORE STOP PRESET Exit programming mode STORE OUT Set maximum extension STORE STOP OUT Clear maximum extension STORE A Set intermediate extension A STORE B Set intermediate extension B STORE C Set intermediate extension C ...