DIGITAL CONTROLLER AND INDICATOR FOR

HEATING OR COOLING WITH NATURAL 

DEFROST THROUGH COMPRESSOR SHUTDOWN

MT-512

 

 

e

 

2HP

 Control functions

shutdown

Functions

lockdown

Serial

programming

Protection

level

Manual

defrost

IP 65

FRONT

Image I: MT-512E 2HP - 115Vac

1. DESCRIPTION

2. SAFETY RECOMMENDATIONS

3. 

4. TECHNICAL SPECIFICATIONS 

Periodical defrost may be performed with 

MT-512

e

 

2HP

 by stopping the compressor (natural 

defrost) and forcing defrost manually. It is provided with a powerful 16A relay for actuating loads of up to 
2HP,  in  addition  to  a  command  output  combined  with  a  timer  for  programming  refrigeration  and 
defrosting  times.  Another  feature  available  is  the  turning  off  of  the  control  functions,  making  the             

MT-512

e

 

2HP

 operate only as a temperature indicator. It is also provided with a configurable 

digital  filter,  which  has  the  purpose  of  simulating  mass  increase  in  the  environment  sensor,  thus 
increasing its response time, i.e., it renders the sensor response slower (delay). Through an intelligent 
function blocking system, it prevents unauthorized personnel from changing the control parameters.

MT-512

e

 

2HP

 can also be set for heating.

Product conforming to UL Inc. (United States and Canada) and NSF

.

 (United States)

 
- Check the controller for correct fastening; 
- Make sure that the power supply is off and that it is not turned on during the controller installation; 
- Read the present manual before installing and using the controller; 
- Use adequate 

 (PPE); 

- For application at sites subject to water spills, such as refrigerated counters, install the protecting vinyl 
supplied with the controller; 
-  For  protection  under  more  critical  conditions,  we  recommend  the  Ecase  cover,  which  we  make 
available as an optional item (sold separately);
- The installation procedures should be performed by a qualified technician.

• Cold storages 
• 

 

• Industrial heating / Cooling equipment
• Any other type of equipment requiring  precise temperature control    

Personal Protective Equipmenet

Reach-In Coolers / Stand Up Coolers

APPLICATIONS 

Control temperature 

(**)

Resolution

5. INDICATIONS AND KEYS

Upper Key

MT-512

e

 

2HP

Lower Key

Set Key

Menu Key (Flatec)

User-friendly 

Cooling indication LED

Heating indication LED

Defrost indication LED

Temperature unit indication LED

Control functions OFF indication LED

Functions lockdown indication LED

- 50 to 105°C (-58 to 221°F)

 0.1°C (-10 to 100°C) and 1°C at the rest of the range

115 Vac

Image III: MT-512EL 2HP - 12Vac/dc

Power supply

MT-512E 2HP: 

115 or 230 Vac 

* (50/60 Hz)

±10%

MT-512EL 2HP: 

12 or 24 Vdc or Vac 

+10%

Maximum load current 

(***) 

16 A for resistive-type loads and 12 A for inductive-type 
loads

Maximum load power 

(***)

2HP

Operating temperature

0 to 50°C / 32 to 122°F

Operating humidity

10 to 90% RH (without condensation) 

(*) Admissible variation in relation to the voltage rating. 
(**) This instrument measures and controls temperatures of up to 

, using the silicone sensor cable SB59 

(sold separately).
(***) For higher loads, use contactor. 

200°C/392°F

Protection level
Dimensions (mm)

Cutout dimensions (mm)

IP 65 (frontal)

76 x 34 x 77 mm (Width x Height x Depth)

X = 71±0,5   Y = 29±0,5  (see image V)

6. WIRING DIAGRAM

6.1. Identifications (see Images I to IV)

- Image I: 

MT-512E 2HP, supplied at 115 Vac. 

- Image II:

 MT-512E 2HP, supplied at 230 Vac. 

- Image III:

 MT-512EL 2HP, supplied at 12 Vac/dc. 

- Image IV:

 MT-512EL 2HP, supplied at 24 Vac/dc.

Image II: MT-512E 2HP - 230 Vac

230 Vac

POWER

12Vac/dc

Image IV: MT-512EL 2HP - 24Vac/dc 

POWER

24Vac/dc

6.2. Temperature sensor connection 

- Connect the sensor wires to terminals ‘1 and 2’: the polarity is not relevant. 
- Length of the sensor cables can be increased by user himself to up to 200 meters, using a PP 2x24 
AWG cable.
- For immersion in water, use a thermowell (Image VI - item 12), available in the Full Gauge Controls 
product line (sold separately).

S u r g e   P r o t e c t i v e  

Device (SPD)

(sold separately)

W i r i n g   d i a g r a m   f o r  

instalation  of  SPD  in 

magnectic contactor

A1 and A2 are the terminals of 
the contactor coil.

SPD

A1

A2

W i r i n g   d i a g r a m   f o r  

instalation  of  SPD  in  line 

with loads

For  direct  drive  take  in  to 
consideration  the  specified 
maximum current.

LOAD

IMPORTANT

SCREWDRIVER SLOT 3/32''(2.4mm) FOR ADJUSTMENTS IN THE SIGNAL TERMINALS;
SCREWDRIVER PHILLIPS #1 FOR ADJUSTMENTS IN THE POWER TERMINALS;

THE USE OF APPROPRIATE TOOLS IS ESSENTIAL TO AVOID DAMAGE IN THE CONNECTION AT INSTRUMENT 
TERMINALS:

CONTROLLER

WIRING

TERMINALS

TEMPERATURE

SENSOR 

WIRING 

TERMINALS

LOAD

CONTROLLER

WIRING

TERMINALS

WIRING 

TERMINALS

TEMPERATURE

SENSOR 

LOAD

CONTROLLER

WIRING

TERMINALS

WIRING 

TERMINALS

TEMPERATURE

SENSOR 

LOAD

CONTROLLER

WIRING

TERMINALS

WIRING 

TERMINALS

TEMPERATURE

SENSOR 

LOAD

SPD

MT512E2HP13-02T

-15381

POWER

GRID

}

POWER

GRID

}

POWER

GRID

}

POWER

GRID

}

E251415

COMPONENT

Have this manual in the palm of 

your hand by

 FG Finder

 application.

Summary of Contents for MT-512E 2HP

Page 1: ...ockdown indication LED 50 to 105 C 58 to 221 F 0 1 C 10 to 100 C and 1 C at the rest of the range 115 Vac Image III MT 512EL 2HP 12Vac dc Power supply MT 512E 2HP 115 or 230 Vac 50 60 Hz 10 MT 512EL 2HP 12 or 24 Vdc or Vac 10 Maximum load current 16 A for resistive type loads and 12 A for inductive type loads Maximum load power 2HP Operating temperature 0 to 50 C 32 to 122 F Operating humidity 10 ...

Page 2: ...ated deactivatedbypressingthekey for4seconds MT 512e 2HP 8 3 3 Function blocking The activation of function blocking feature allows safety against undue alterations of the Setpoint and of the other parameters In this condition when trying to alter the values the message LOC will be displayed However theparameterscanstillbeseen In order to perform the function blocking the parameter F20 Time for fu...

Page 3: ...quipment are connected in the same electric grid The delays should be adjusted at different values for eachpieceofequipment NOTE After the end of delay the minimum output off time count is started if it has been set in parameterF09 F15 Additionaltimetotheendofthefirstcycle Itisusedtoincreasetheworkingtimeonlyofthefirstrefrigerationcycle increasingtheefficiency F16 Compressorsituationwithdamagedsen...

Page 4: ...ols Damage has been caused by a fall blow and or impact infiltration of water overload and or atmospheric discharge USE OF WARRANTY To make use of the warranty customers must send the properly packaged product to Full Gauge Controls together with the invoice or receipt for the corresponding purchase As much information as possible in relation to the issue detected must be sent to facilitate analys...