background image

Getting Started

 

fi-5110C Image Scanner

 

P3PC-1072-03EN

Getting Started

fi-5110C Image Scanner

Summary of Contents for ScanSnap fi-5110C

Page 1: ...Getting Started fi 5110C Image Scanner P3PC 1072 03EN Getting Started fi 5110C Image Scanner ...

Page 2: ......

Page 3: ...hecking the Contents of the Scanner Package 1 1 2 Names of Parts 1 1 3 Operator Panel 2 Chapter2 INSTALLATION OF THE SCANNER 3 2 1 Installing the Scanner Application 3 2 2 Installing the Scanner 9 2 3 Connecting the USB Cable 10 2 4 Confirming Installation 11 Appendix 1 TROUBLESHOOTING AP 1 Appendix 2 DAILY CARE AP 4 Appendix 3 REPLACING CONSUMABLES AP 5 ...

Page 4: ...r Connect the equipment into an outlet on a circuit different from that to which the receiver is located Consult your dealer or an experienced radio TV technician FCC warning Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Canadian DOC Regulations This digital apparatus does not exceed the Class B limi...

Page 5: ... by the user or a third party About the Use of Mercury To avoid unexpected injury read the following carefully Doing the following actions may result in serious personal injuries Do not put the substance contained in the lamp in your mouth as it has mercury Do not breathe the chemical liquid contained in the scanner lamps Do not incinerate crush or shred the lamps or scanner parts Trademarks Micro...

Page 6: ... manual are subject to change without notice in the interest of product improvement If the actual displayed screen differs from the screen examples in this manual operate by following the actual displayed screen while referring to the User s Manual of the scanner application you are using The screenshots in this manual were captured from FUJITSU TWAIN32 scanner driver ScandAll 21 Image Capturing U...

Page 7: ...ric shock and or equipment failure Use this scanner only at the indicated power voltage and current Improper power voltage and current might cause fire or electric shock Do not connect to multiple power strips Do not touch the power plug with wet hands Doing so might cause electric shock Wipe off any dust from metal parts on the power plug or metal fittings with a soft dry cloth Accumulated dust c...

Page 8: ...at will support the weight of the scanner and other devices Do not block the ventilation ports Blocking the ventilation ports generates heat inside of scanner which may result in fire or scanner failure Do not place heavy objects on the scanner or use the scanner s surface top to perform other work Improper installation might cause injuries and equipment failure Firmly insert the power plug as far...

Page 9: ... sunlight When the scanner is not going to be used for a long period of time be sure to disconnect the power plug from the power outlet for safety Do not install the scanner under direct sunlight or near heating apparatus Doing so might cause excessive heat to build up inside the scanner which can cause scanner trouble or even fire Install the scanner in a well ventilated location ...

Page 10: ...t is included in the package box If any parts are missing or defective contact your sales representative 1 2 Names of Parts This section describes the scanner parts Front Rear Removable Parts Parts that can be removed from the scanner are dis played below ADF open lever Operator panel Stacker Automatic document feeder ADF ADF paper chute Side guide USB Interface connector DC inlet Security Cable S...

Page 11: ...er to the ready status 1 press Scan or Send to button E Indicates that a device hardware alarm has occurred during scanning of documents E and the alarm Number 2 to 9 and c will appear alternately To return the scanner to the ready status 1 press Scan or Send to button If this alarm occurs turn the power off and on again If the alarm continues after turning the power on again contact your service ...

Page 12: ... into the CD drive SETUP DISK START UP SCREEN appears 3 Click INSTALL PRODUCTS ATTENTION Please install the scanner driver before connecting the scanner to your PC If you connect the scanner before installing the scanner driver the scan ner will not operate correctly If you have connected the scanner beforehand the Found New Hard ware Wizard screen appears this screen might differ slightly accordi...

Page 13: ...the Setup CD ROM from the CD drive until your PC has completely restarted Installation of the scanner driver is completed Installing ScandAll 21 Scandall 21 is an image capturing software that com plies with the TWAIN standard The FUJITSU TWAIN 32 scanner driver enables you to capture images with a FUJITSU image scanner fi series product 1 Insert the Setup CD ROM into the CD drive SETUP DISK START...

Page 14: ...ows 2 Insert the Setup CD ROM into the CD drive SETUP DISK START UP SCREEN appears 3 Click INSTALL PRODUCTS ATTENTION For finishing the installation it may be necessary to restart your computer Follow the instructions on the window ATTENTION Windows XP screenshots are used in this section as examples The win dows and operations may vary slightly depending on your OS ATTENTION When using Windows 20...

Page 15: ...ted Installing QuickScan Pro QuickScan Pro is an image capturing software that complies with the ISIS standard The FUJITSU ISIS scanner driver enables you to capture images with a FUJITSU image scanner fi series product 1 Insert the Setup CD ROM into a CD drive SETUP DISK STARTUP SCREEN appears 2 Click INSTALL PRODUCTS 3 Click QuickScan PRO Trial on the window below 4 Continue to install the appli...

Page 16: ...OM in your CD drive The SETUP DISK STARTUP SCREEN will appear 2 Click Install Products 3 Click Error Recovery Guide on the next screen 4 Select a language to use for the installation in the Choose Setup Language window and click OK 5 Install the application following the instructions in the window ATTENTION QuickScan Pro included in the Setup CD ROM is an evaluation ver sion For further use after ...

Page 17: ...w appears 2 Select the language and Click OK button 3 Select Install Adobe Acrobat 7 0 Standard 4 Click the Next button The set up window appears ATTENTION Adobe Acrobat 7 0 Standard is not supported by Microsoft Windows 95 Microsoft Windows 98 98SE Microsoft Windows NT4 0 Microsoft Windows Me HINT Adobe Acrobat is required for display ing the manuals stored in the CD ROM Installation of Adobe Acr...

Page 18: ... time Letter strings embed ded in the image or the background may be missed Solution 1 Set Edge shadow removal to OFF or set any option other than Adaptive for Color Grayscale and or Mono chrome under Compression by selecting File Create PDF From Scanner Image Set tings in Acrobat Solution 2 Adjust the scanning density in the TWAIN driver 2 Setting Adaptive for Color Gray scale and or Monochrome u...

Page 19: ...a request for inserting the CD ROM for Windows 98 appears insert it into the CD drive and click the OK button For Windows 2000 When Digital Signature not Found appears click Yes The installation of the scanner is completed ATTENTION Use only the AC adapter provided by the manufacturer HINT The Function Number Display and the LED may flash for an instant when plugging the AC cable into the scanner ...

Page 20: ...f ScandAll 21 4 Select FUJITSU fi 5110Cdj on the dialog box 5 Select To View from the Scan menu 6 Set scanning resolution document size etc on the TWAIN driver window for setting details of scanning and click the Scan button 7 Documents are scanned and the scanned images are displayed on the ScandAll 21 win dow If the scanning completes without any trouble the installation performed successfully F...

Page 21: ...t Preview Settings from the Scan menu Set the scan resolution paper size and other scanning requirements and then click OK 5 Select Preview Scan from the Scan menu And then the document is scanned If the scanning completes without any trouble the installation performed successfully HINT Refer to QuickScan Overview or QuickScan Help for information about QuickScan Pro functions and opera tions On t...

Page 22: ...reload the documents on to ADF paper chute Is the ADF closed completely Close the ADF completely Is the USB cable cable connected securely Connect the cable When a USB hub is used check the hub s power supply Does the Function Number display indicates an alarm or an error When the Function Number display indi cates an alarm or an error refer to Chap ter 6 TROUBLESHOOTING in the fi 5110C Operator s...

Page 23: ...rator s Guide s Document Quality and the Multi Feed Detection Conditions of chapter 7 been satisfied Use document conditions that meet the Document Quality and the Multi Feed Detection Conditions in the chapter 7 of the fi 5110C Operator s Guide Is the Pick roller dirty To clean the pick roller refer to Operator s Guide in Chapter 4 Daily Care Is the Pick roller worn out Change the Pick roller Ref...

Page 24: ... to 6 TROUBLESHOOTING in the fi 5110C Operator s Guide on the Setup CD ROM Device alarm Non Temporary error When you encounter any alarm on the display turn the scanner off and on If the alarm is still displayed on the Function Number display contact the store where you purchased the scanner or an authorized FUJITSU scanner service provider Indication Meaning U1 Paper feed error U2 Multi Feed erro...

Page 25: ...the Feed rollers or Eject rollers Cleaning Materials Parts Number Remarks Cleaner F1 or isopropyl alcohol CA99501 0013 1 bottle Moisten the cloth with this fluid and wipe the scanner clean Lint free dry cloth Commercially available one ATTENTION Do not use aerosol sprays to clean the scanner Aerosol sprays can blow dirt and dust inside the scanner resulting in scanner failure or malfunction Part t...

Page 26: ...eaned The illustration below demonstrates the locations of the replacement parts Refer to Chapter 5 Replacing Consumables fi 5110C Operator s Guide on the Setup CD ROM Replacing the Pad ASSY Replacing the Pick Roller WARNING During its operation the inside glass of the ADF becomes very hot Before replacing the consumables turn the scanner off and unplug the AC adapter from the outlet Wait at least...

Page 27: ...manual are subject to change without notice z PFU LIMITED is not liable whatsoever for any damages resulting from use of this scanner and procedures described in this manual profit due to defects and any claims by a third party fi 5110C Image Scanner Getting Started P3PC 1072 03EN Date of issuance June 2006 Issuance responsibility PFU LIMITED Printed in China ...

Reviews: