background image

TABLE OF CONTENTS 

Safety Precautions ...............2~5 

Maintenance ................................4

Precautions on Use......................5 

Preparation ..........................6, 7 

Name of Parts ..........................6, 7

Switch ..........................................7 

Installation .........................8~14 

Preparation and Check 

before Installation ...................8, 9

Cooker Hood Installation ....10~13

Operation Check .......................14 

Maintenance ......................14~16 

Caution for Maintenance ............14

Detaching/Attaching 

Cleaned Parts ........................15, 16

Cleaning ......................................16 

Other Information .............17, 18 

Specifications ..............................17

Circuit Diagram ..........................17

Troubleshooting..........................18

Service and Warranty..................18 

Cooker Hood 

Thank you very much for your purchase of our cooker hood. 

Before installing/operating the cooker hood, please read 

this Manual thoroughly. 

To the sales shop/installer:

A

er installation, please 

give this manual to the user 

without fail. 

Installation/Operation Manual 

FR-MT1990V 

(Ventilating Type) 

(Recycling Type) 

FR-MT1990R 

Ventilating Type 

Recycling Type 

Keep this manual in a convenient place for future reference. 

Содержание FR-MT1990

Страница 1: ...g 16 Other Information 17 18 Specifications 17 Circuit Diagram 17 Troubleshooting 18 Service and Warranty 18 Cooker Hood Thank you very much for your purchase of our cooker hood Before installing operating the cooker hood please read this Manual thoroughly To the sales shop installer A er installation please give this manual to the user without fail Installation Operation Manual FR MT1990V Ventila...

Страница 2: ... AC Fire or electric shock may result in Using prohibited Be sure to disconnect the power plug from the wall outlet or switch off the breaker when care and maintenance Also don t handle the power plug or breaker with wet hand Electric shock or injury may result in Disconnect the plug When dust accumulated on the blades of the power plug or on their roots wipe off well Fire may result in Wipe off dust...

Страница 3: ... into the room Air supply cautioned Mounting cautioned Mount the product securely a er selecting a solid place Dropping may result in injury Improper discharge prohibited The minimum distance between the wok pan support of the hob and the lowest part of the cooker hood should be at least 750mm when the cooker hood is located above the hob If the instructions for installation of the hob specify a g...

Страница 4: ...f the power cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Replace the cord if it s damaged Wear gloves Be sure to wear gloves during care and maintenance Injury by the sharp edges or corners may result in Prohibited Do not put anything on the cooker hood It may be cause of fire failure or injury by dropping Opera...

Страница 5: ...lso the surface of the cooker hood may suffer dew condensation if it is used in low temperature In this case use the cooker hood a er wiping off During operation pay attention to sufficient air supply Provide adequate air intake slots on the wall opposite from the cooker hood or open the door of the room a little Otherwise ventilation performance may be deteriorated or abnormal noise vibration may re...

Страница 6: ... Preparation Ventilating type Recycling type Main unit LED Fixing screw Filter Rectifier panel Oil tray Fan Fan Guard Duct Cover Slide Duct Cover Recycling Device Recycling type Duct Cover Fixing Bracket 2 pieces Hanging Bracket ...

Страница 7: ...desiring quick air exchange Timer button 3 6 9 minutes delay for shutdown of the whole machine under working state Lamp ON OFF ON OFF of independently controlling the lamp FR MT1990V Ventilating type Name Usage Quantity 1 1 1 1 1 1 2 FR MT1990R Recycling type 4 2 7 7 4 1 1 1 1 1 1 1 2 1 1 1 1 Name Usage Quantity Name Usage Quantity Duct Cover Duct Cover Slide Duct Cover Slide Duct Cover Recycling ...

Страница 8: ...ck into the room 1 Mount the cooker hood carefully and avoid contact with any metal parts the lath in the wall or the like of the building 2 Never embed the body of the cooker hood in the wall Otherwise electricity might leak in the wall which in any case flows to the body of the cooker hood 4 The minimum distance between wok pan support of the hob and the lowest part of the cooker hood Should be ...

Страница 9: ...lation location Unit mm Body mounting hole seven places FR MT1990V FR MT1990R 600 1030 Ventilating type 600 650 Recycling type 750 80 80 Hanging Bracket Duct Cover Fixing Bracket 306 120 10 5 316 76 200 900 289 505 550 60 Power cord 97 91 187 ...

Страница 10: ...to the fan guard Use the appropriate accessories for installation see page 7 Note 4 5 pieces of ST5 50 wood screws installation size on page 9 The duct cover fixing bracket and the hanging bracket are fixed on the wall If you use a plastic expansion pipe use a Ø10mm drill bit to drill holes in the wall The hole diameter is Ø10mm and the depth is 55mm or more Filter Fixing Screw ST4 8 Flat head scr...

Страница 11: ...ntilating type as shown in the right figure cut the flexible tube duct to the required length and shrink it before installing the flexible tube duct Applicable to ventilating type Flexible Tube Duct Taping with non flammable materials Aluminum tape etc 8 Assemble the combination of duct cover and slide duct cover to the main unit While assembling please fit the lower part of the duct cover combinat...

Страница 12: ...exible Tube Duct Slide Duct Cover Duct Cover Ventilating type Recycling type 12 For the ventilating type please lengthen the telescopic flexible tube duct and connect it to the exhaust pipe connected to the outside with a flame retardant metal tape Flexible Tube Duct Exhaust Pipe As shown in the figure to the right the ventilating type is equipped with a flexible tube duct and then it is mounted o...

Страница 13: ... slot 15 Install the rectifier panel A Put the rectifier panel on two rear hooking brackets of the main unit B Turn the rectifier panel horizontally align it with the le and right ball catchers and push it forward towards the main unit Note Ensure that the ball catchers in the rectifier panel is completely clamped in the clamp anchor If it is not installed in place there may be a risk of falling I...

Страница 14: ...ult to remove the hardened grease Before cleaning the cooker hood be sure to disconnect the power plug from the receptacle or turn off the breaker For safety always wear a pair of rubber gloves while cleaning the filter etc Especially be careful to prevent electric parts such as the motor switch connectors or the like from coming into contact with water Do not spray liquid or any types of detergent...

Страница 15: ...l is fully clamped in the ball catch Install all parts using the opposite procedure as that for removing the parts Oil Tray Detaching Attaching Cleaned Parts Note The oil tray may be filled with oil so be careful when removing it When removing the oil tray be sure to hold the rectifier panel by hand to avoid accidental falling off and causing injury Note If the oil tray is not installed properly it...

Страница 16: ... When cleaning use a neutral detergent and so cloth Do not use an organic solvent A er cleaning wipe the hood well with a wet cloth dipped in water to remove any remaining detergent and finally thoroughly wipe any moisture off using a dry cloth Note When cleaning the rectifier panel perform it on a flat surface in order not to deform it Oil tray Rectifier panel Filter When cleaning use a neutral de...

Страница 17: ... 34 52 45 35 With 2 1 5W 3W Watts for lamp FR MT1990R Recycling type Rated voltage V Speed Frequency Hz Power consumption W Air flow h Sound dB 220 230 240 Hi Med Low Hi Hi Med Med Low Low 50 50 50 126 117 99 134 123 104 143 128 114 260 205 120 270 220 130 270 230 140 56 50 39 56 52 40 57 53 41 With 2 1 5W 3W Watts for lamp Square Diameter 33 2mm 120mm Max Power Voltage Picture Lamp Cap ILCOSD cod...

Страница 18: ...emove other filters except the original one 2 Clean the filter 3 Open the window and the air inlet ensure sufficient air supply 4 Prevent from being blown by the wind 5 Request smoke repairing Service and warranty When requesting a er sales service If any abnormality occurs while the cooker hood is in operation switch off the cooker hood check the following points 1 Whether the fuse in the circuit b...

Страница 19: ... Website www fujioh com FUJIOH INTERNATIONAL TRADING PTE LTD Southeast Asia Regional Headquarters 130 Joo Seng Road 05 05 Singapore 368357 Tel 65 6286 3286 Fax 65 6285 3285 E mail fit fujioh com sg Rev3 2020 ...

Отзывы: