background image

Summary of Contents for FAC09C3ABJW

Page 1: ...FRIGIDAIR INSTRUCTIONS MANUAL SPL T TYPE ROOM AIR CONDITIONER ATTENTION Please read this manual completely before operating your room air conditioner ...

Page 2: ...u for choosing our product We hope you will consider us for future purchase Environmental advices The packaging material used is recyclable we recommend that you separate plastic paper and cardboard and give them to recyoling companies According to WEEE Waste of Electrical and Electronic Equipment guidelines waste from electrical and electronic devices should be collected separately If you need to...

Page 3: ...29 5 7 Gas leak check 29 5 8 Test running 30 06 Operation 6 1 Preparing the device for operation 31 6 2 Product description 32 6 3 Remote control 34 Remote control operation Remote control specifications Remote control battery When should the batteries be replaced To replace batteries Remote control instructions 6 4 Remote control description 36 On Off Temp increase Temp decrease Swing Clock Turbo...

Page 4: ...tenance 46 08 Operation tips 48 09 Solution for problems 50 I0 Technical specifications 51 Attention The air conditioner that you have bought may be slightly different from the one illustrated in this manual Please refer to the information related to the model you have This air conditioner is for domestic use only It is not reccomended for commercial or industrial use The air conditioner you have ...

Page 5: ...ther appliances It may cause electric shock or fire due to heat generation 3 Always ensure effective earthing No earthing may cause electric shock 4 Disconnect the power if strange sounds smell or smoke comes from it tt may cause fire and electric shock 5 Keep firearms away It may cause fire 6 Do not operate or stop the unit by switching on or off the power tt may cause electric shock or fire due ...

Page 6: ...n the unit during operation It may cause electric shock 15 Do not use the power cord near flammable gas or combustibles such as gasoline benzene thinner etc It may cause an explosion or fire I Ventilate room before operating air conditioner if there is a gas leakage from another appliance It may cause explosion fire and burns 17 Do not disassemble or modify unit It may cause failure and electric s...

Page 7: ...ices food pets plants and art objects It may cause deterioration of quality etc 24 Stop operation and close the window in storm or hurricane Operation with windows opened may cause wetting of indoor and soaking of household furniture 25 Turn off the main power switch when not using the unit for a long time It may cause failure of product or fire 26 Do not use strong detergent such as wax or thinne...

Page 8: ...ration without filters may cause failure 29 Do not place heavy object on the power cord and take care so that the cord is not compressed There is danger of fire or electric shock 30 Do not place obstacles around air inlets or inside of air outlet It may cause failure of appliance or accident ...

Page 9: ...nit 1 The unit must be installed at a site that does not obstruct the flow of air 2 The site must support the weight of the indoor unit 3 The site must be easily accessible for maintenance and replacement of the air filter 4 The site must allow for the necessary space around the indoor unit as shown in the following figure 5 There should be at least 1 meter 3 feet between the unit and radio and te...

Page 10: ... be installed at a site where the noise produced by its operation and air discharge does not disturb the neighbors or animals 5 The site cannot have any leakage of flammable gases 6 The site must allow for a piping extension of no less than 5 meters 16 feet and for pipes measuring at least 10 meters 33 feet in length 7 The site must provide enough space around the unit as shown in the diagram 8 Ch...

Page 11: ...Parts list Endoor unit Outdoor unit L oj ...

Page 12: ...e than Air filte More than A More than 60cm More than 60cm B C More than 200cm Outdoor Unit Attention 1 This illustration is for explanation purposes only 2 Copper lines must be insulated independently _ J ...

Page 13: ...odels t2D00 Btu s A 790 8 265 above 120ram from the wall pipe hole right _ 65 Indoor unit outline above 120ram from the walt Refrigerant p pe hole left 0 65 above 150ram 920 A above 120ram from the waU 4_F Refrigerant pipe hole right 0 65 l_doo_ unit out i_ above 120mm from the wail Refrigerant p_pe hole _ above 150ram from the ceiling Installation plate i above 120ram i from the wall efrigeraht p...

Page 14: ...late 1 Install the installation plate horizontally over the structural parts on the wall using the spaces indicated on the plate as shown in the figure above 2 In the case of tiled concrete or similar walls create 5 mm diameter holes Place anchorage supports for the appropriate assembly screws 3 Fix the installation plate to the wall with 8 A type screws A ttention Fit the installation Plate and d...

Page 15: ...ate the connecting part of extension drain hose with a shield pipe do not let the drain hose slack Do not put the end of drain hose into water Connective pipe 1 For the left hand and right hand piping remove the pipe cover from the side panel Explain to clients that the pipe cover must be kept as it may be used when relocate the air conditioner to any other place P_pe cover Pipe Pipe cover right h...

Page 16: ... unit from side to side to see that it is securely hooked 3 Piping can easily be made by lifting the indoor unit with a cushioning material between the indoor unit and the walt Get it out after finish piping 4 Push the lower part of the indoor unit up on the wall Then move the indoor unit from side to side up and down to check if it is hooked securely Upper hook Lower hook material ...

Page 17: ...Attention 1 Connect the indoor unit first then the outdoor unit 2 Do not allow the piping to let out from the back of the indoor unit 3 Be careful not to let the drain hose slack 5 Heat insulated both of the auxiliary piping 6 Be sure that the drain hose is located at the lowest side of the bundle Locating at the upper side can cause drain pan to overflow inside the unit 7 Never intercross nor int...

Page 18: ...h as in coastal areas place the unit along the widest part of the wall or use protective plates 7 If need suspending installation the installation bracket should accord with technique requirement in the installation bracket diagram The installation wait should be solid brick concrete or the same intensity construction or actions to reinforce damping supporting should be taken The connection betwee...

Page 19: ...ain joint installation Fit the seal into the drain elbow then insert the drain joint into the base pan hole of outdoor unit rotate 90 to securely assemble them Connecting the drain joint with an extension drain hose Locally purchased in case of the water draining off the outdoor unit during the heating mode Seal Drain joint Drain pipe Base pan hole of outdoor unit ...

Page 20: ...tle longer than the measured distance D Cut the cable 1 5m longer than the pipe length 2 Burr removal A Completely remove all burrs from the cut cross section of pipe tube B Put the end of the copper tube pipe in a downward direction as you remove burrs in order to avoid dropping burrs into the tubing 3 Putting nut on A Remove flare nuts attached to indoor and outdoor unit then put them on pipe tu...

Page 21: ... pipe Clamp handle Connection Adjustment 1 Align the pipes to be connected 2 Unscrew the flare nut with your fingers and then with a wrench and screw wrench as shown in the following figure indoor unit Flare tubing nut Caution Excessive twisting may break the nut depending on the installation conditions ...

Page 22: ...tch with a 1 5 times capacity of Max Current of the unit should be installed in power circuit 4 Ensure the air conditioner is grounded well 5 According to the attached Electrical Connection Diagram located on the panel of the outdoor unit to connect the wire 6 All wiring must comply with local and national electrical codes and be installed by qualified and skilled electricians 7 An individual bran...

Page 23: ... loosening the screw 4 Ensure the colour of wires of outdoor unit and the terminal Nos are the same fo the indoors respectively 5 Wrap those cables not conneded with terminals with insulation tapes so that they will not touch any electrical companents Securethe cable onto the control board with the card clamp Electrical box cover _ 18000 btu s CABLE Cooling model Cable code 1Omm _ 18000 btu s CABL...

Page 24: ...EATING AND COOLING MODEL Connector A or Connector B Terminal block of indoorunit To outdoor To outdoor unit unit 24000 Btu s 30000 or 36000 Btu s HEATING AND COOLING MODE HEATING AND COOLING MODE Connector A Connector A _ or Connector B Terminal block of indoor unit Terminal block of indoor unit or I To outdoor To outdoor To outdoor unit unit unit ...

Page 25: ...on 245 IEC 57 H07RN F or heavier cord 3 Secure the cable onto the control board with the cord clamp 4 To prevent the ingress of water from a loop of the connective cable as illustrated in the installation diagram of indoor and outdoor units 5 Insulate unused cords conductors with PVC tape Process them so they do not touch any electrical or metal parts _ 18000 btu s CABLE Cooling model Cablecode 0t...

Page 26: ...r A or Conector B Wire connector of outdoor unit board board Conector C or Conector D Tablero terminal de Ia unidad externa Nboard board 24000 Btu s HEATING AND COOLING MODEL Conector A or Conector B Wire connector of outdoor unit W__I o o_ o o o Cables board board 30000 or 36000 Btu s HEATING AND COOLING MODEL onector A Wire connector of outdoor unit UWboard ...

Page 27: ...ickness is as specified in the power source specification 7 Always install an earth leakage circuit breaker in a wet or moist area 8 The following would be caused by voltage drop Vibration of a magnetic switch which will damage the contact point fuse breaking disturbance of the normal function of the overload 9 The means for disconnection from a power supply shall be incorporated in the fixed wiri...

Page 28: ...es on the outdoor unit are kept closed at this stage 2 When relocate the unit to another place perform evacuation using vacuum pump 3 Pipe length and refrigerant amount Caution in handling the packed valve t Open the valve stem untie it hits against the stopper Do not try to open it further 2 Securely tighten the valve stem cap with a spanner or the like Valve stem cap tightening torque See Tighte...

Page 29: ...es and a compound meter indicates 0 instead of minus 5 After the evacuation is complete fully close the handle Lo of the manifold valve and stop the operation of the vacuum pump Make evacuation for I5 minutes or more and oheck that the compound meter indicates 76cmHg Ix10 Pa 6 Turn the stem of the packed valve B about 45o counterclockwise for 6 7 seconds after the gas coming out then tighten the f...

Page 30: ... use the electroprobe and mu timeter to perform the electrical leakage check Turn off the unit immediately if leakage happens Check and find out the solution ways till the unit operate properly Gas leak check Soap water method Apply a soap water or a liquid neutral detergent on the indoor unit connection or outdoor unit connections by a soft brush to check for leakage of the connecting points of t...

Page 31: ...se the MODE button to select COOL HEAT AUTO and FAN to check if all the functions works well 3 When the ambient temperature is too low lower than 17 C the unit cannot be controlled by the remote controller to run at cooling mode manual operation can be taken Manual operation is used only when the remote controller is disable or maintenance necessary _ _ Auto CooiO Manual control button Manual co u...

Page 32: ...every two weeks 5 This air conditioner was designed for use under the following conditions Room Temperature i i i 5 C 43 C cooling only Attention If air conditioner is used outside of the above conditions certain safety protection features may come into operation and cause the unit to function abnormally Room relative humidity less than 80 If the air conditioner operates in excess of this figure t...

Page 33: ...l Infra red signal receiver Drain hose connector and refrigerant gas connector Remote control Connector cable Detection valve Drain hose and refrigerant connecting pipe Air iniet Indoor Air outlet Air inlet Attention All the pictures in this manual are for explanation purpose only They may be slightly different from the air conditioner you purchased Air outlet Outdoor unit ...

Page 34: ... when is in Fan mode only Note Only for models with Cooling only and 18 000 Btu s INFRA RED SIGNAL RECEIVER _ DIGITAL SCREEN Show the present adjustments to temperature when air conditioner is operating OPERATION indicator This indicator flashes after power is on and illuminates when the unit is in operation TIMER indicator This indicator illuminates when TIMER is set O N O FE Attention The descri...

Page 35: ... our other materials block the signals between the remote control and the indoor unit 2 Avoid spilling any liquid in the remote control Do not expose to sunlight or any heat source 3 If the infrared signal receiver in the indoor unit is exposed to sunlight the air conditioner unit might not work properly Use curtains or shades to avoid having sunlight directly to the receiver 4 If other electrical...

Page 36: ...e two AAA batteries in the compartment indicated in the drawing located inside the compartment 3 Slide in the cover 4 If the remote control is not operated for long period of times batteries should be discarded Remote control instructions 1 The signal reach distance of the remote control to the receiver that is inside the main unit of the air conditioner is 8 meters Any obstruction placed between ...

Page 37: ...select the time TURBO Press this button on cooling heating mode to go into powerful cooling heating operation Press againto cancel it Note 1 Only for some models Note 2 For models with PTC only MODE Each time you push the button a mode is selected in a sequence that goes from AUTO COOL DRY HEAT and FAN as the following figure indicates AUTO_ COOLi_ DRYI_ HEAT I_ FAN t J FAN SPEED This button is us...

Page 38: ...ion _ TIMER Is used to select the turning on time and turning off time of the air conditioner _ CANCEL 1 If the timer is TIMER ON TIMER OFF and the function has been configured press cancel and it will cancel the timer program and turn off the unit 2 If the timer is TIMER OFF only mode press the button Cancel and it will cancel the timer program and turn the unit off Note This function works only ...

Page 39: ...Heat mode Fan mode Auto clean AUTO CLEAN 2H _ Temperature display Block t Horizontal airflow up down Vertical airflow left right _n Timer set f J U U Attention All the items are shown in the screen to have a clear and precise explanation But only the actual function items will be shown in the visualization panel During the actual operation this indicator will not be shown in the panel of the indoo...

Page 40: ...ly or fan only operation depending on what temperature you have selected and the room temperature 2 The air conditioner will control room temperature automatically round the temperature point set by you 3 If the AUTO mode is uncomfortable you can select desired conditions manually COOL HEAT and FAN ONLY operation 1 if the AUTO mode is not comfortable you may manually override the settings by using...

Page 41: ... SPEED isLow Push theON OFF button again to stop thisunitoperation Attention Due to the difference of the set temperature of the unit and the actual indoor temperature the Air Conditioner when in DRY mode will automatically operate many times without running the COOL and FAN mode o Set temperature DRY Function Air flow direction adjustment Use SWING to adjust the airflow direction up and down 1 Wh...

Page 42: ...he Coot Heat and AUTO mode l J J S o E e SLEEP FUNCTION Cooling mode oo I I SLEEP FUNCTION Heating mode TIMER Operation TIMER button can set the auto on time of the unit To set the starting time 1 Push the TIMER ON button then the remote controller shows TIMER ON the last set time for the starting operation and the signal h will be shown on the DIGITAL DISPLAY area You are now ready to reset the t...

Page 43: ...mp On Te r_p Off ON ON ONN oFLJ 12h 14h 20h 23h rempOf0 TeTepOn Temp On Temp Off Optimal operation To achieve optimal performance please note the following 1 Adjust the air flow direction correctly so that it is not directed on people 2 Adjust the temperature to achieve the highest comfort level Do not adjust the unit to excessive temperature levels 3 Close doors and windows on COOL or HEAT modes ...

Page 44: ...the vertical louver manually using the lever on the left or right side of the vertical louver arm Depending on model Take care not to catch fingers on the fan horizontal louver or to damage vertical louvers When the air conditioner is in operation and the horizontal louver is in a specific position move the lever at left or right depending on model end of the air outlet to the desired position To ...

Page 45: ...ON or SWING button If you move this louver manually it may malfunction during operation If the louver malfunctions stop the airconditioner once and restart it When the air conditioner is started immediately after it was stopped the horizontal louver might not move for approximately 10 seconds Open angle of the horizontal louver should not be set too small as COOLING or HEATING performance may be i...

Page 46: ...tton will lead to the forced AUTO operation 3 Close the panel firmly to its original position Attention Once you push the manual button the operation mode is shifted in an order as AUTO COOL OFE Push the button twice the unit will operate in forced COOL mode This is used for testing purposes only Third press will stop the operation and turn off the air conditioner operation To restore the remote c...

Page 47: ... powder or similar solvents for cleaning These may cause the plastic surface to crack or deform Cleaning the air filter A clogged air filter reduces the cooling efficiency of this unit Please clean the filter once every 2 weeks 1 Lift the indoor unit panel up to an angle until it stops with a clicking sound 2 Take hold of the handle of the air filter and lift it up slightly to take it out from the...

Page 48: ...lits Fig 3 _ _ Suppo_ frame Maintenance If you plan to idle the unit for a long time perform the following 1 Operate the fan for about half a day to dry the inside of the unit 2 Stop the air conditioner and disconnect power Remove the batteries from the remote controller 3 The outdoor unit requires periodic maintenance and cleaning Do not attempt to do this yourself Contact your dealer or servicer...

Page 49: ...or unit The indoor or outdoor fan stop running when defrosting Cooling and heating models only A white mist coming out from the indoor unit A white mist may generate due to a large temperature difference between air inlet and air outlet on COOL mode in an indoor environment that has a high relative humidity A white mist may generate due to moisture generated from defrosting process when the air co...

Page 50: ...dreleases itviathe indoor unitduring heating operation When theoutdoor temperature falls heat drawn inbytheairconditioner decreases accordingly Atthesame time heat loading oftheairconditioner increases due tolarger difference between indoor andoutdoor temperature Ifa comfortable temperature can t be achieved by the air conditioner we suggest you use a supplementary heating device Auto restart func...

Page 51: ...t is obstructed 8 The capacity of the equipment is not adequate for the size of the room 9 Air conditioner was just turn on 10 Windows or doors are open 11 Motor protector has been activated The unit does not start 1 The plug is not connected to the outlet 2 No electricity in the outlet 3 The voltage is different 4 Temperature is not adjusted properly 5 burned fuse 6 The remote control batteries n...

Page 52: ...Technical specifications COOLING MODELS HEATING COOLING MODELS ...

Page 53: ...Notes ...

Page 54: ...Notes ...

Page 55: ...Notes _ _ii_i _i_i_ _i _i _ i_i_i_ i_i_ i _i_i_ _ i _ _ _iii_i_ _i_ii_ _ i _ _i_ i _ii_iii i _ii_i_ _i_ii_i_ _ i_ _ _ii_ii_ i _ ...

Page 56: ...i ili_i i_ _ii_ii_iiii_i_i_ii_ _ii _i_ ii_ ii _i_i_ _ i_ii_ii_iiiii _iii_ ii_ii_ iiiiiii_i i_i_ii_i_iiii _i_i_i _i_ iii_ii_i _i_iii _i _ _ii _ _i _ _i_ii i_ ii_iii_i_iiiii_ ii _ i_ii_i _iii_ Z_ _ _ _ __i_ii_i_ iiKii_iii_i _i_ _iiii_i F R IGI D_ R _ii_ _ _ ...

Page 57: ...FRIGIDAIR ATENCION Lea todas las instrucciones antes de utilizar el aparato y guardelas para futuras ...

Page 58: ... instalaci6n y operaci6n antes de utilizar su acondicionador de aire y gu rdelas en un lugar seguro para futuras consultas Frigidaire una vez mAs fabrica Io mejor en Io que se refiere a electrodomesticos Consejos ambientales E material deI embalaje es reciclable Procure separar pl sticos espuma flex papeI y cart6n y enviarlos alas compaSias de recictaje De acuerdo con la directriz de la RAEE Resid...

Page 59: ...ento 30 06 Operaci6n 6 1 Preparando el aparato para hacerlo funcionar 31 6 2 Descripci6n del producto 32 6 3 Como funciona et control remoto 34 Caracteristicas del control rernoto Cargar el control remoto Se deber_ sustituir las pilas cuando Para sustituir las pilas Instrucciones de uso del control remoto 6 4 Descripci6n del control remoto 36 Encender apagar Mas Temperatura Menos Temperatura Swing...

Page 60: ...ion manual sin control remoto 45 07 Mantenimiento y cuidados 46 08 Consejos de operaci6n 48 09 Guia para la soluci6n de problemas 50 10 Especificaciones tecnicas 51 Atenci6n 1 El aparato que usted ha comprado puede set tigeramente diferente del que se muestra en las figuras de este manual la forma en general deber4 ser la misma 2 Este acondicionador de aire ha sido proyectado para uso domestico No...

Page 61: ...ra del telefono Despu_s de la instalaci6n verifique que no haya fugas 2 Utilice los cables especificados para conectar las unidades intema y extema con seguridad y conecte los cables firmemente alas secciones de la placa de los bornes para que las tensiones no se apliquen a las secciones La conexi6n o co ocaci6n incorrecta podria originar fuego 3 No haga funcionar ni detenga la unidad enchuf ndolo...

Page 62: ...ja elflujodeaire enla direcci6n delosocupantes dela habitaci6n esdaSino para Ia salud Potlosmisrnos motivos tampoco exponga plantas o animales alflujo directo delaire 9 Desenchufe elaparato cuando no 1o vaya ausar porunlargo periodo detiempo elac 3mulo desuciedad podria causar fuego 10 Instale uninterruptor fusible dela capacidad nominal para evitar posibles choques el6ctricos 11 Cuando vaya alimp...

Page 63: ... las salida de aire de acondicionador de aire debido a peligro de incendio I6 No instale el acondicionador de aire en lugares en los que haya gases inflamables o combustibles como gasolina benceno solventes etc 17 No utitice el acondicionador de aire para otros propuestos como atmac n de equipos de precisi6n comida pintura etc que requieren ciertas condiciones de temperatura y humedad pues su cali...

Page 64: ... aparatos fuente de calor ventile bien el recinto 23 No abra el aparato durante el funcionamiento 24 No ponga objetos pesados sobre el cable de alimentaci6n el6ctrica y asegQrese de no aplastarlo 25 No desarme ni modifique el aparato 26 Tome cuidado al desempacar y instafar la unidad 27 AsegOrese de que no entre agua a los componentes el6ctricos 28 Mantenga cualquier arma de fuego alejada del elec...

Page 65: ...eso para realizar el manteniemiento y el oambio del filtro de aire en su aparato 4 Un lugar que provea los espacios requeridos alrededor de la unidad intema como se muestra en el gr fico abajo 5 Un tugar que tenga pot Io menos mas de un metro de distancia con respecto a un televisor instrumentos de radio En el centro del lugar es perfecto 6 Un lugar alejado deI fuego humo y gases inflamables 7 La ...

Page 66: ...n 4 Un lugar en donde el ruido producido por el funcionamiento y descarga del aire no moleste a sus vecinos o animales 5 Un lugar sin fugas de gases inflamables 6 Un lugar que permita una elevacion de las tuberias no menor de 5 metros y con una Iongitud de tuberias de pot Io menos 10 metros 7 Lugares en los que haya espacio suficiente en tomo de esta unidad como se muestra en el diagram 8 Un lugar...

Page 67: ...Lista de piezas Unidad tnterna Unidad Externa ...

Page 68: ...nos de 2 m Un recorrido minimo de 4 a 5 men las tuberias requeddo para minimizar la vibraci6n y el ruido en exceso Dos de las tres Direcciones A B o C en la gr_ fica deben estar sin ning_n tipo de bloqueo 2 Esta ilustraci6n es solo con prop6sito explicativo La forma de la placa de instalaci6n puede variar dependiendo del modelo 3 Las lineas de cobre deber n ser aisladas independientemente ...

Page 69: ...talaci6n 120ram o m_s de ta pared Agujero de Ia gerante derecha O 65 Contorne de Ia unidad ir_tema 120ram o mas de la pared 150ram del techo 920 A Placa de instalaciTn 120mm o m _a de la pared Agujero de Ia tuberfa refdgerante derecha O 65 120ram o m_ s de la pared Agujero de ta _uberia refdgerante iz quierda _ 65 Placa de instalacion Contomo de la unidad intema _ 150mm del techo de Ia pared 1 0 9...

Page 70: ...6n horizontalmente sobre las partes estructurales en la pared usando los espacios indicados en la p aca come muestra a figura de abajo 2 En el case de paredes de ladrillo concrete o similares perfore orificios de 5 mm de diametro Introduzca los apoyos de anc aje para los tornillos de montaje adecuados 3 Fije ta placa de insta aci6n sobre la pared corn 8 tornillos tipo A Atenci6n Ajustar la instala...

Page 71: ...parte en donde va a conectar la manguera y utitice un protector de tuberias para que quede bien fija Tubo de coexidn 1 Para ias tuberias de la derecha y la Cubr izquierda remueva el cobertor de la tuberia tuberia del panel lateral derecha Explique a los clientes que deben guardar la cobertura de la tuberia par ser reutifizada en caso que se cambie de sitio el acondicionador 2 En la parte fraser de...

Page 72: ...se enganch6 en forma segura 3 Las tuberias pueden set hechas fAcilmente al levantar la parte interior de la unidad con material acolchado entre la parte interior de la unidad y la pared Saque el material acolchado despues de poner la tuber 4 Empuje la parte de abajo de la unidad interne contra la pared tuego mueva la parte interior de la unidad de un lado a otto y de arriba hacia abajo pare cheque...

Page 73: ...te Atenci6n 1 Conecte primero la parte interior de la unidad y luego la parte exterior 2 No permita que la tuberia se salga de la parte trasera del interior de la unidad 3 No permita que la manguera de drenaje quede floja 4 Aislar el calor de ambas tuberias auxiliares 5 AsegQrese de que la manguera de drenaje quede ubicada en la parte m s baja de la envoltura de la cinta de fo contrario at dejarla...

Page 74: ...ci6n 5 Si es necesario instalar el acondicionador de aire en suspensi6n el soporte de instalaci6n debera estar de acuerdo con fa t6cnica necesaria en el diagrama del soporte de instalaci6n La pared de instalaci6n debe ser de ladritlos s61idos hormig6n o similares con la misma robustez o se deberA tomar acciones para reforzarla amortiguarta o apoyarla La conexi6n entre el soporte y la pared y entre...

Page 75: ...del drenaje Fije el sello en el codo det drenaje inserte e empaime del drenaje en el agujero bajo de la base de la unidad externa rote 90 grados para ensamblartos con seguridad Conecte el empalme del drenaje con una extensi6n de manguera de desag_3e comprada localmente en caso de que drene agua de la unidad externa en el modo calefaccidn _ Aran_ Arandela Junta de drenaje Junta de drenaje JAgujero ...

Page 76: ...rga de 1oque mida la distancia 9 f _i que acaba de tomar _ _ D Corte el cable 1 5 metros m s W largo de la tuberia 2 Removiendo las impurezas A Remueva completamente as impurezas de la secci6n cruzada de code B Coloque el extremo del tubo de cobre hacia abajo mientras etimina las irregularidades para evitar que caigan impurezas en el tubo 3 Cofocacion de las tuercas A Remover la tuerca ajustada en...

Page 77: ...cobre deI tornillo Ajuste de la conexi6n 1 Alinear el centro de los tubos 2 Ajuste la tuerca con los dedos y Juego con la llave y una llave torque como se muestra en la figura abajo Tubo de la unidad exterior _Jberias Tuercas PrecauciOn Un excesivo ajuste puede romper la tuerca dependiendo de as ondiciones de instalacidrt ...

Page 78: ...mentaci6n principal con una capacidad de 1 5 veces en relaci6n a la corriente m xima 4 Aseg irese que el acondicionador est_ con el polo a tierra 5 De acuerdo al diagrama de conexiones electricas ubicadas en el panel de la unidad externa conecte el cable 6 Todo el cableado debe respetar el Standard el_ctrico nacional y local y ser instalados por un electricista 7 Utilice un circuito Onico para est...

Page 79: ...rtes el6dricas 4 Conectar los cables a los termina es de ocuerdo a sus marcas 5 Envolver los cabTesno conedados con cinto aisladora y tape los cables de tat manera que esfosno foquen ning_n componente el_ctrico tapas de las partes electricas _ 18000 btu s CABLE Modelo frio _ _le 1gram _ 18000 btu s CABLE Modelo frio y calor _CableA o Cable B lOmm lOmm 18000 btu s CABLE Modelo frio y calor Cable C ...

Page 80: ...IO Y CALOR Conector A o Conector B Tablero terminal de fa unidad interna Hacia la Hacia la unidad externa unidad extema 24000 Btu s 30000 o 36000 Btu s MODELO FRIO Y CALOR MODELO FRIO Y CALOR Conector A Conector A o Conector B Tablero terminal de ia unidad interna Tablero terminaI de la unidad intema Hacia la Hacia ta Hacia la unidad extema unidad externa unidad extema ...

Page 81: ...l ingreso de agua forme una curva con el cable conector de las unidades 4 Aisle los cables conduotores que no utilJza con cinta PVC Proceda a envolvedos de manera que no toquen ninguna parte el_ctrica o met lica TornilIo 18000 btu s CABLE Modele frio lOmm 18000 btu s CABLE Modelo frio y oalor Cable D o Cable E C6digo deI cable 10ram lOmm 18000 btu s btu s CABLE Modelo frio y calor Cable F C6digo d...

Page 82: ...de Ia unidad externa de cables _ _JTabIe_ de sables Conector C o Conector D Tabtero terminal de la unidad externa _ _ Tablero decables decables 24000 Btu s MODELO FRIO Y CALOR Conector A o Conector B Tablero terminal de Ia unidad extema _ I IS _ _ tTIIIIT I z _j_ Tablets de cables de sables 30000 o 36000 Btu s MODELO FRIO Y CALOR Conector A Tabiero terminaI de Ia unidad externa 1 1 de cables ...

Page 83: ...mpre instale un circuito interruptor con polo a tierra en un _rea hSmeda o mojada 8 Consecuencias de una caida de voltaje VibraciSn del interruptor magn6tico Io cual deteriorar el punto de contacto ruptura de fusible alteraciones negativas en el funcionamiento normal de ta sobrecarga 9 Los medios para la desconexi6n de una fuente de alimentacidn ser n incorporados en et cableado fijo y tendr_ n un...

Page 84: ...rradas en esta etapa 2 Cuando se mueve la unidad a otro lugar se debe realizar la evacuaci6n usando la bomba de vacio 3 Largo de tuberias y monto refrigerante Atenci6n al manipular la v_ilvula 1 Abra el v stago de la v_lvula hasta que golpea contra el tope No intente seguir abriendo 2 Apriete con firmeza el casquillo vAstago de la v lvula con una llave dinamom6trica El casquillo v stago de la valv...

Page 85: ...nos 5 Despu_s que la evacuaci6n haya terminado cierre completamente a manija Lo de la vAlvuta Manifold y pare la operaci6n e la bomba de vaci6 Reatizar la evacuaci6n por 15 minutos o m s y revisar que el medidor compuesto indique 76cmhg 100KPa 6 Gire en sentido contrario al las agujas del reloj el vastago de la v_ Ivula B unos 45 grados a ia izquierda por 6 7 segundos despu_s de que el gas salga u...

Page 86: ...hequeo de fuga de electricidad Apague la unidad inmediatamente si detecta fuga Revise y encuentre las soluciones basra que Eaunidad funcione perfectamente Control de fuga de gas M_todo del agua y jab6n Aptique una soluci6n de agua con jab6n o un detergente liquido neutro sobre la conexi6n de la unidad interna o en las conexiones de la unidad externa con un cepillo suave para comprobar la fuga de l...

Page 87: ... hasta que et indicador de operaci6n encienda la luz la unidad funcionar en el modo enfriamiento forzado 3 Revise si todas las funciones estan trabajando Especialmente asegt3rese de que el drenaje de a unidad interna funcione sin problemas 4 Presione el bot6n manua otra vez despu6s de terminar lade encendido El indicador de operaciSn se tornar_ oscuro y ta unidad deiarA de funcionar El bot6n de co...

Page 88: ...ado la unidad pot largo tiempo se recomienda limpiar el filtro de aire antes de usarlo en ella Para uso continuo limpie el filtro de aire por Io menos una vez at aiqo Antes de encender la unidad aseg0rese de que las rejillas de la entrada y de la salida de aire no est6n obstruidas Este acondicionador de aire ha sido dise_ado para funcionar bajo las siguientes condiciones 5 0 43_C soto sistema de f...

Page 89: ...oi6n Receptor de seSal infra rojo Enchufe de la manguera de drenaje y tubo conector refrigerante _ Control remoto Cable coneotor _ V tvula de detenci6n Manguera de drenaje y tubo conector refrigerante Entrada de aire Unidad interna Salida de aire Entrada de Aire Atenci6n Todas las gr_ficas de este manual son simplemente para prop6sitos explicati vos Poddan ser un poco distintas a tas caracter stic...

Page 90: ... est en la funci6n solo ventilaci6n Nora solo para los modelos frfos 4500 frigorias _ Receptor de sehal infra rojo _ Pantalla digital Muestra los ajustes de _emperaturas vigentes cuando el acondicJonador de aire est funcionando _ Operacion Un indicador intermitente Ie avisar_ cada segundo despu6s del encendido y se iluminara cu ndo el aire se encuentre en funcionamiento TIMER Temporizador El indic...

Page 91: ...ionador de aire no funcionar_ si cortinas puertas u otros materiales bloquean las sefiales entre el control remoto y la unidad interior 2 Evite que cualquier Ifquido caiga sobre el control remoto No exponga el control remoto a la luz solar directa ni al calor 3 Si el receptor de la serial infrarroja de la unidad interior se encuentra expuesto a la luz solar directa es posible que el acondicionador...

Page 92: ...el receptor y el control remoto puede causar interferencia en la seSat 2 3 limitando la capacidad de programaci6n de aparato Cada vez que se presiona un bot6n del control remoto el acondicionador de aire emite un sonido beep que indica que se ha transmitido y se ha recibido un comando una seSat en la unidad interna At seleccionar Jafunci6n del temporizador el control remoto transmite automaticamen...

Page 93: ...n CLOCK Es usado para seleccionar la hora del retoj TURBO At presionar este bot6n en los modos FRIO Cool CALOR Heat et acondicionador cambia a una operacion de refrigeraciSn o calefaccibn de mayor potencia Presione nuevamente el boton para cancelar la funci6n TURBO Nota 1 Esta funci6n no est disponible en todos los modelos Nota 2 para modelos con PTC o calentador el6ctriconible en todos los modelo...

Page 94: ...peraci6n excepto la actual en el bloqueo _ TEMPORIZADOR Es usado para seleccionar la hera de encendido OII o apagado OFF del acondicionador de aire CANCEL 1 Si el temporizador est_ TIMER ON TIMER OFF y la funcion se ha configurado pulse el bot6n Cancel y anular_ el programa de temporizador y apagar4 Ia unidad 2 Si el temporizador estA ajustado solo en TIMER OFF pulse el bot6n Cancel y anular_ el p...

Page 95: ...AN Modo Auto Modo Frfo Modo deshumidificaci6n Modo Calor Modo Ventilador Auto Limpieza I_ Flujo del aire hacia arriba Flujo dei aire hacia la izquierdaiderecha n u _u Ajuste del Timer Atenci6n Todos los items son mostrados en _apantalla con el prop6sito de aclarar su presentaciSn Pero sotamente los items de la funci6n actual ser n mostrados en et panel de visualizaci6n Durante la operaci6n actual ...

Page 96: ... puede elegir 16gicamente el modo FRIO VENT CALORy SECO sintiendo la diferencia de la temperatura actual del ambiente y la temperatura fijada en et control remoto 2 En et modo AUTO no es posible cambiar la velocidad del ventilador Dicha velocidad es controlada autom_ticamente 3 Si el modo AUTO no le resulta confortabte puede seleccionar et modo deseado manualmente Operaciones FRIO CALOR y SOLO VEN...

Page 97: ...bido a la diferencia entre la temperatura etegida y la temperatura ambiente el acondicionador de aire cuando est6 en el modo SECO operar6 muchas veces automaticamente sin pasar al modo FRIO o VENT j Temperalura T ambiente j t _ _ Tiempo Sefeccionar temperaturas Funci6n de deshumid_ficaoi6n Ajuste de la direcci6n del flujo de aire Use tos botones D1RECCION DEL AIRE y SWING Oscilaci6n para ajustar l...

Page 98: ...nci6n DORMIR s61ose encuentra disponible con los modos de refrigeraci6n calefacci6n y AUTO I5 f Funci6n DORMIR Modo frio t 1hour lhaur I 7haurs i Funci6n DORMIR Modo de caiefacci6n Operaci6n del temporizador Timer Presione TEMPORIZADOR para ajustar las horas de encendido y apagado Para ajustar la hora de encendido 1 Por favor presione el b6ton TEMPOR ENC para cancelar todos los ajustes anteriores ...

Page 99: ..._g _mpo_A _g _mpor Ehc_nd ENCEND APAG _ APAG I I I 20h 23h _mpo_Encend_ _mponApeg_ Funcionamiento 6ptimo Para asegurar un 6ptimo funcionamiento por favor observe Io siguiente 1 Ajuste el aire para que no tlegue directamente alas personas 2 Ajuste la temperatura para alcanzar er nivel de confort mAs alto No 1oajuste a niveles extremos 3 Cierre puertas y ventanas en los modos FRIO y CALOR para mejor...

Page 100: ...do al modo en que se encuentre funcionando Para ajustar la direcci6n horizontal izquierda derecha Ajuste la rendija vertical manualmente usando la patanca que esta en el lado izquierdo o derecho del brazo vertical de la rendija esto depende del modelo No introduzca los dedos en el ventilador o daSar_ la rendija horizontal o vertical Cuando el acondicionador de aire est6 prendido y la rendija horiz...

Page 101: ...uperficie de la rendija horizontal causando humedad o liquidos No mueva la rendija manualmente Siempre use el bot6n SWING Si Io hace presentar fallas en el funcionamiento si esto sucede apague el equipo y vuelvalo a prender Cuando el aire es prendido inmediatamente despu_s de apagarlo la rendija horizontal no se mover_ por aproximadamente 10 segundos La abertura deI Angulo horizontal no debe ser m...

Page 102: ...n modo AUTO la temperatura se ajustar a 24 C 3 Cierre el panel a su posici6n iniciat Atenci6n Una vez que usted oprima el bot6n manual este serA activado siguiendo el orden AUTO FRIO y APAGADO Presione el bot6n hasta que el indicador ENCENDIDO se destelle 5 veces por segundo fa unidad ahora estarA funcionando en modo FRIO Este es utilizado solo para propdsitos de prueba Cuando el indicador de OPER...

Page 103: ...dran causar que la superficie de pl_stico se rompa o deforme 6 No toque las pares met_ Iicas cuando remueve el filtro Puede lesionarse 7 No use agua al limpiar el interior del acondicionador de aire podria afectar el aislamiento y asi provocar descargas el_ctricas Limpiando el filtro de aire Un filtro taponado reduce la eficiencia del equipo Por favor limpielo 2 veces pot semana 1 Levante la puert...

Page 104: ...ectamente ahora ubique el fittro completo en la posici6n inicial Filtro Soporte del marco refrescante _ __ deaire__ N _ _ _ rezrescante Fig 1 Fig 2 de alre Soporte deJ marco Fiitro _ __ de aire Fig 3 Sopo_edelma_o Mantenimiento Si usted planea parar el equipo por un tiempo largo haga Io siguiente 1 Haga funcionar el ventilador pot medio di a para que seque el interior de la unidad 2 Pare el acondi...

Page 105: ...emperatura exterior y la cantidad de helada que haya crecido dentro de Ia unidad externa El ventilador interno o externo se apagar_ cuando est_ en proceso de descongelamiento Solo para los modelos con refrigeraci6n calefacci6n Una niebla blanca saliendo de la unidad interna Una niebla blanca se generar_ debido a una gran diferencia de temperatura entre el aire entrante y el saliente estando en ef ...

Page 106: ...alor para los modelos con refrigeraci6n calefacci6n El acondicionador de aire dirige el calor desde la unidad externa y Io descarga en la unidad interna durante el proceso de calefacci6n Cuando la temperatura exterior desciende el calor que pasa al acondicionador de aire disminuye por consiguiente AI mismo tiempo el calor alrnacenado en el acondicionador de aire se incrementa debido a la gran dife...

Page 107: ...del ambiente 9 Se ha acabado de encender el acondicionador de aire 10 Est_n abiertas puertas o ventanas 11 La protecci6n de motor se ha activado La unidad no enciende 1 El enchufe no est devidamente conectado al tomacorriente 2 Falta de energia el_ctrica en e tomacorriente 3 La tensi6n de la red el_ctrica no es la correcta 4 La temperatura est mal ajustada 5 Vet si el fusible se ha quemado 6 La un...

Page 108: ...i i _ _i _iTi i i i _ _ i i_ i _ _ i ii_ Peso ne_o unidag externa kg_ ii 53 8a MODELO FRIO CALOR Altura unload iatema ram 265 225 330 i i i i325 _ _ Pe o nero nidad inlerna kg 7 5 i 18 Altura unidad externa I_mm 250 590 6 5 _ i _i_ _i _860 i i i i Peso neto un_dad extema kg 32 38 53 _ 65 ...

Page 109: ...Notas ...

Page 110: ...Notas ...

Page 111: ...Notas ...

Page 112: ...FRIGIDAIR ...

Reviews: