background image

Summary of Contents for CAD304NUL10

Page 1: ...iiiiiiiiiiiiii_jiiiiiiiiiiii iiiiiijiiiii iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiil TABkE i Location How It Works Operating InstructiohS www frigidaire com USA1 888 775 6937 www frigidaire ca Canada 1 800 265 8352 ...

Page 2: ...ed by a time delay fuse or circuit breaker have a qualified electrician install the proper outlet according to the National Electrical Code and applicable local codes and ordinances Do not use an extension cord or an adapter plug Never unplug the dehumidifier by pulling on the power cord Always grip the plug firmly and pull straight out from the receptacle Do not pinch bend or knot the power cord ...

Page 3: ... floor that will support it with a full bucket of water 5 There should be a minimum of 12 inches clearance around the dehumidifier Location How It Works When the unit is started the fan begins to pull moisture laden air across the dehumidifying coils The coils condense or draw moisture from the air and air flows through the top louvers into the room as dry warm air Moisture removed from air is col...

Page 4: ...l hi clean filter low I filter fan speed V A Lhum_d_ty J timer ON OFF J 2 To turn the unit on press the ON OFF button The unit will run in the factory setting of CONTINUOUS and high fan speed In the CONTINUOUS mode the unit will only display CO and not the room humidity It is recommended you leave the unit running in the CONTINUOUS setting for the first three or four days until the sweating and da...

Page 5: ...t full clean filter hi m I low I fan speed filter V A timer ON OFF Lhum_d_ty J j 4 You can also use the FAN SPEED button to change the fan speed to HIGH or LOW The indicator light will show the setting you have selected A higher fan speed will result in quicker moisture removal m bucket full clean filter hi I low I fan speed filter V A timer ON OFF Lhum_d_ty J 5 The CLEAN FILTER light will illumin...

Page 6: ...intained will be the same as previous setting After TIMER setting finishes pressing TIMER button again at any time will stop the TIMER function The Delay Start Stop Feature will work until the unit either starts or stops Once that happens the above steps have to be repeated 1 Before entering TIMER setting make sure power is being supplied to the unit 2 Before entering TIMER setting make sure press...

Page 7: ...as shown in the photographs below and empty the bucket Discard water from bucket Water is not potable and cannot be used for drinking e Replace the empty bucket back into the unit and once seated correctly the unit will start up again fl You should hear a click when the bucket is in the correct position If the bucket full light does not extinguish check that the float is correctly snapped in place...

Page 8: ...mall leak then replace the hose gasket and re tighten the hose 2 It is recommended that a Dehumidifier Drain Hose 1 2 12 7 ram or larger be used Make sure there are no kinks or elevations in the hose 3 If the mode of continuous drainage is not chosen the drain cap must be screwed securely to prevent leakage Care and Cleaning 1 Filter a Remove the filter every two weeks based on normal operating co...

Page 9: ...cleaner to clean grill See Care and Cleaning Dehumidifier must be placed in a space that does not restrict air flowing into the rear coil or out of the front grill Dehumidifier has been installed or restarted recently The higher the moistuire in the room the longer the dehumidifier will operate Dehumidifier is in the CONTINUOUS mode and will remain on in this mode use the humidity button or knob t...

Page 10: ...mages to the finish of appliance or home incurred during installation including but not limited to floors cabinets walls etc 13 Damages caused by services performed by unauthorized service companies use of parts other than genuine Electrolux parts or parts obtained from persons other than authorized service companies or external causes such as abuse misuse inadequate power supply accidents fires o...

Reviews: