background image

 

 

1

 

Rev. D

 

Model: FRLB6

 

Service Manual

 

Summary of Contents for FRLB6

Page 1: ...1 Rev D Model FRLB6 Service Manual...

Page 2: ...2...

Page 3: ...e Front Door OOPS Flippin Door is Open OOPS Something s in the Way of the Cup Holder OOPS Wrong Cup Size HEY The Product is not Cold Enough to be Blended WE RE SO SORRY The Blender Needs Water to Blen...

Page 4: ...p Up Door to clean off any product build up around the blending chamber rim and gasket Be careful not to damage the gasket Panels Screens Daily Blender Maintenance 4 2 1 Open front door and locate the...

Page 5: ...twork General Service Procedures Network General Service Procedures BACK Network General Service Procedures BACK Blender Info Sanitize Time Sanitize Description LVCB Status Window Reset Screen Cleanin...

Page 6: ...Manual Electrical System Error 66 Pump Motor Peak Current Limit Exceeded TRIGGER Pump Motor current exceeds 9 5 amps 1 Access the Main Menu and press the Clear Errors button 2 Remove the left side pa...

Page 7: ...tus Window button and locate Line Q HomeSN A If it reads HomeSN 0 and the Cup Holder is in the home position replace the Home Sensor Parts Manual Linear Motion System Error 6E Steamer Thermistor Short...

Page 8: ...t from side to side It is the silicone nozzle situated on the ceiling of the chamber to the left of the blending shaft 5 Access the Main Menu and select the Procedures tab and press the Activate Clean...

Page 9: ...teamer tank is receiving 120VAC by measuring at the elements on top of the heater If no voltage is present measure the VAC between the bottom post on the Thermal Cutout white wire and the main post wh...

Page 10: ...a If no voltage is present remove the right side panel and proceed to step 5 b If 120VAC is present replace the Steamer Heater Parts Manual Water System 5 Remove the right side panel to verify the St...

Page 11: ...lugged when replacing parts and practice caution when testing voltages A Ensure the wire harness from the Pump Motor is securely connected to the HVCB at TB9 B Ensure the White Jumper cables between t...

Page 12: ...range proceed to the Step 3 D b If out of range replace the Chamber Thermistor Parts Manual Water System D Measure DC voltages for the Chamber Thermistors on the Pinch Guard Assembly at P2 a If there...

Page 13: ...was requested while sanitize is in progress or hasn t completed in 24 hours TRIGGER 2 A manual sanitize stop was requested after the previous sanitize failed 1 Access the Main Menu and press the Clea...

Page 14: ...coming off or damaged replace the Flip Up Door Parts Manual Mechanical System 2 Check the operation of the Flip Up Door Manually operate the door The Flip Up Door should have spring tension but should...

Page 15: ...of the WPR into a large cup C Connect the Female QD back to the blender you should have good water pressure a If no water pressure is present replace the Female Quick Disconnect Parts Manual Water Sy...

Page 16: ...F A Perform the Squeeze Test by squeezing a chocolate milkshake in the middle of the cup You should be able to squeeze a dime size dent in the cup If not the product is too cold for blending B Ensure...