background image

Plumbers Tape 

Tape Measure

Adjustable Wrench

Screwdriver

Drill

Hex Wrench

Level

Pencil or Marker

Thread Sealant 

*not included

POSSIBLE TOOLS REQUIRED*

Before you begin, please read the installation instructions below. Observe 

all local building and safety codes.

Unpack  and  inspect  the  items  for  any  shipping  damages.  If  you  find 

damages, do not install.

Please note all products must be installed by a professional and certified 

plumber otherwise warranty might be voided.

BEFORE YOU BEGIN

Product code: FS10120

1

FONTANA RENO DARK OIL RUBBED BRONZE 3 WAY 

DIGITAL SHOWER SYSTEM INSTALLATION 

INSTRUCTIONS

FontanaShowers

©

FontanaShowers

©

FontanaShowers

FontanaShowers

Customer Service: 800-684-4489

fontanashowers.com

Summary of Contents for FS10120

Page 1: ...y codes Unpack and inspect the items for any shipping damages If you find damages do not install Please note all products must be installed by a professional and certified plumber otherwise warranty might be voided BEFORE YOU BEGIN Product code FS10120 1 FONTANA RENO DARK OIL RUBBED BRONZE 3 WAY DIGITAL SHOWER SYSTEM INSTALLATION INSTRUCTIONS FontanaShowers FontanaShowers FontanaShowers FontanaShowe...

Page 2: ...lations Instruction Parts Step 3 Step 1 D C E F F Mark the 4 drilling positions then use the Ø6mm drill to drill holes on the wall according to the marked hole position Inset the plug D into the hole hold the fix base C use the tapping screw D through fix base C holes tighten the tapping screw D tighten the top shower fixed bar E and the inlet hose F with the fix base C ...

Page 3: ...hower with the top shower fixed bar E then connect with the inlet hose F 2 Inlets For RainShower are provided in big shower heads so the water disperses equally throughout the showerhead The installation is completed Note The LED lights are powered by water flow and will be activated once the water is turned on E F Step 5 Step 6 ...

Page 4: ...ssary If installing bodysprays in a bank of 4 or greater a pressure balancing loop must be used to keep the pressure even between the bodysprays Body Jets Spray Installations Instruction Step 2 Apply teflon tape to threaded tail pipe of the body spray G 2 Step 3 Press the escutcheon against the finished wall Step 4 Screw the Body spray tightly into the female of water Supply Step 1 Attach the escutc...

Page 5: ... installations require the selection of a suitable solder or compression fitting Install the Wall Outlet thread long male 1 2 BSP into the appropriate female fitting using PTFE tape to give a watertight joint Note The thread can be cut to size if required Make sure that all debris is removed from the connector and the section that has been cut is dressed correctly before installation The minimum req...

Page 6: ...6 FontanaShowers FontanaShowers FontanaShowers FontanaShowers Customer Service 800 684 4489 fontanashowers com Digital Mixer 3 way Installations Instructions Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 ...

Page 7: ...7 FontanaShowers FontanaShowers FontanaShowers FontanaShowers Customer Service 800 684 4489 fontanashowers com Step 7 Step 8 Step 9 Step 10 ...

Page 8: ...tanashowers com Step 11 Step 12 Step 13 1 Hand Shower s Mixer Water Outlet 2 Hot Water Inlet 3 Cold Water Inlet 4 5 The Control Cable 6 The Host Box Installation Bracket 7 3 Way Water Outlet Valve 8 The Control Panel Installation Bracket 1 Fly Shuttle Switch 2 Setting 3 Spray Button 4 LCD Display ...

Page 9: ...When Installing It Please Avoid To Let It Face Directly To The Water From The Hand Shower And The Head Shower Because Water Will Get It Misoperation Or Lock The Control Panel 2 The Touch Button Is The Best Sensitive Area 3 The Touch Panel Has Water Splash Protection Technology When The System Detects Misoperation No Response And Need About 1 Second To Recover Function 1 Water TEMP Adjust 2 Hand Sh...

Page 10: ...wise System Will Enter Into The Water TEMP Adjusting Again If There s No Touch On The Panel For 5 Seconds Water TEMP Will Be Memory And Exit The Water TEMP Adjusting Touch Setting Button Again To Enter Into Water Flow Adjusting Icon On The LCD Panel Will Stop Flashing The Fly Shuttle Switch Backlight Color Will Change According To The Water TEMP As Below Blue Color Water TEMP 33 C Blue Orange Colo...

Page 11: ... Abnormal Alarm When Water TEMP Is Over 49 Celsius Degree System Will Stop Working And No Water Outlet Automatically You Could Hear 3 Times Of Buzzer Sound And The LCD Panel Shows Error Code EE Back Up Battery 1 When System Working Based On Battery LCD Panel Shows The Current Battery Status When System Working By The Local Power Supply And Battery Is Not Full LCD Panel Shows Charging Status Until ...

Page 12: ...The Adapter When You Install The Host Box Please Put The Battery Into It If The Product Hasn t Connected With The Power In A Long Time Please Take Out The Battery From The Host Box This Way Can Avoid Affecting The Battery Working Life If You Want The Battery With Longer Working Life You Can Charge The Battery Every Some Month Battery Installation 1 Loose The Screws On The Battery Cover And Take It...

Page 13: ...he Shower Panel Putting Some Glass Cement Around The Back Of The Control Panel And Fit It In The Hole Of The Shower Panel As The Picture Shows Step 2 Fasten The Mounting Bracket Onto The Back Of The Control Panel By Screws Step 3 Install The Host Box On The Back Of The Shower Panel Connect The Cold Water And Hot Water Pipe Hand Shower And Head Shower s Pipes Step 17 Installation Of Control Panel S...

Page 14: ...t Box Control Cable With The Control Cable Of Shower Faucet As An Arrow Mark On The Picture Caution When Connecting The Two Control Cables You Must Follow The Arrow Mark Which Is Shown In The Cable Joint If Not It Will Damage The Cable Joint Step 5 Connect The Power Supply Cable Of The Host Box With The Adapter Step 21 Recess Mounted Into The Wall Step 22 Recess Mounted Into The Wall A The Install...

Page 15: ...Off The Cold Water And Hot Water Supply Lead Cold And Hot Water Pipe From The Cold Hot Water Supply To The Cold And Hot Water Inlet Of The Host Box 3 Connect The Head Shower And Hand Shower Pipe To The Marked Water Outlet Of The Host Box 4 Connect The Power Adapter To The Power Cable Of The Host Box 5 Connect The Control Cable Between The Control Panel And The Host Box 6 Get AC220V Power Supply To...

Page 16: ...eaning products containing ammonia bleaches alcohol dyes acids hydrochloric formic phosphorus chlorine or acetic will be not be affected All products manufactured and supplied by Fontana are safe and comply to legislative requirements Providing they are installed correctly and receive regular maintenance in accordance with these instructions your user experience will not be affected 6 If using a s...