PCS-516 DUO

Time relay,

10-function

The PCS-516 DUO time relay is used for time control in industrial 

and home automation systems (such as : ventilation, heating, 

lighting, signaling, etc.).

A

A. ON delay

After the supply voltage is switched on (the green LED U is on), 

the contact remains in position 11-10 and the set operating time 

counts down. After the preset time has elapsed, the contact swi-

tches to position 11-12 (the red LED   is on). To execute the 

operating mode of the relay again you need to switch off the 

power supply voltage and switch it back on.

Purpose

Features of work

F&F Filipowski sp. j.

Konstantynowska 79/81, 95-200 Pabianice, POLAND

phone/fax (+48 42) 215 23 83 / (+48 42) 227 09 71

www.fif.com.pl; e-mail: [email protected]

Do not dispose of this device in the trash along with other waste! 

According to the Law on Waste, electro coming from households free of charge and can 

give any amount to up to that end point of collec� on, as well as to store the occasion of 

the purchase of new equipment (in accordance with the principle of old-for-new, regard-

less of brand). Electro thrown in the trash or abandoned in nature, pose a threat to the 

environment and human health.

Summary of Contents for PCS-516 DUO

Page 1: ...again you need to switch off the power supply voltage and switch it back on Purpose Features of work F F Filipowski sp j Konstantynowska 79 81 95 200 Pabianice POLAND phone fax 48 42 215 23 83 48 42 227 09 71 www fif com pl e mail biuro fif com pl Donotdisposeofthisdeviceinthetrashalongwithotherwaste According to the Law on Waste electro coming from households free of charge and can give any amoun...

Page 2: ...measured the red LED is on To execute the operating mode of the relay again you need to switch off the power supply voltage and switch it back on C C ON delay cyclic On delay operating mode is carried out cyclically at equal in tervals between the preset operating time and break time D D OFF delay cyclic Off delay operating mode is carried out cyclically at equal in tervals between the preset oper...

Page 3: ...lses G Generating a single pulse with time t by the trailing edge of the signal During the time measurement the system does not react to pulses H Off delay with back up feature The rising edge of the si gnal causes the relay to be switched on while the trailing edge causes the start of time measurement Applying the signal during the time measurement causes the cycle to be extended ...

Page 4: ... signal During the time measurement the system does not react to signal When the RESET voltage is applied during the execution of the given function it causes for functions A B C D F the implementation of the operating mode from the beginning for functions F G H I the return of the relay to the initial state and waiting for the signal for function K permanent switching on of the relay contact in p...

Page 5: ... permanently in position 11 10 Using the time range setting knob T set one of the selected ranges then using the time setting knob T set the selected va lue on a scale from 1 to 12 The product of these values is equal to the operating time for example 1 m 7 7 min Using the dial set one of the functions for example func tion A off delay Working time setting Working mode setting ...

Page 6: ... time range of 1 12 0 1s 0 1 1 2sec 10m 10 120min 1s 1 12sec 2h 2 24godz 10s 10 120sec 1d 1 12days 24 288h 1m 1 12min 2d 2 24days 48 576h ON when the power supply is on the contact is perma nently closed in position 11 12 OFF when the power supply is on the contact is perma nently closed in position 11 10 1 Turn off the power supply 2 Fix the relay on a rail in the switchboard 3 Connect the power ...

Page 7: ... 7 4 Connect the power supply circuit of the receiver in series to terminals 11 12 Wiring diagram ...

Page 8: ... 8 Description of terminals ...

Page 9: ...y 195 253 V AC 21 27 V AC DC maximum load current AC 1 8 A contact separated 1 NO NC working time adjustable 0 1 s 576 h activation delay 50 ms power supply indication green LED contacts state indication red LED power consumption 0 8 W terminal 2 5 mm screw terminals tightening torque 0 4 Nm working temperature 25 50 C dimensions 1 module 18 mm mounting on TH 35 rail protection level IP20 Technica...

Page 10: ...owski sp j declares that the device is in conformity with the essential requirements of The Low Voltage Directive LVD 2014 35 EU and the Electromagnetic Compatibility EMC Directive 2014 30 UE The CE Declaration of Conformity along with the references to the standards in relation to which confor mity is declared can be found at www fif com pl on the product page Warranty CE declaration ...

Page 11: ......

Reviews: