background image

installation guide and user manual

open flue built-in fireplaces 

40 010 535

03 35

SILVA B11

SPECTRA B11

Saturnus 8

NL-8448 CC Heerenveen

Postbus 219

NL-8440 AE Heerenveen

T. +31(0)513 656500

F. +31(0)513 656501

Summary of Contents for SILVA B11

Page 1: ...stallation guide and user manual open flue built in fireplaces 40 010 535 03 35 SILVA B11 SPECTRA B11 Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501 ...

Page 2: ...NG 21 6 1 Check pilot ignition 21 6 2 Functional burner check 21 6 3 Spillage test 22 6 4 Flame Supervision Blocked Flue Monitoring System 22 6 5 Check reference pressure 23 7 HANDING OVER 24 8 SERVICING 25 8 1 Routine annual servicing 25 USER GUIDE 33 9 SAFETY INSTRUCTIONS FOR THE USER 34 9 1 General safety instructions 34 10 CONTROLING THE APPLIANCE 36 10 1 Lighting the fire 36 10 2 To light 37 ...

Page 3: ... local distribution conditions identification of the type gas and pressure and the adjustment of the appliance are compatible This gas appliance is factory set and shall not be adjusted by the installer The spillage monitoring system must not be put out of operation This appliance does not contain any component manufactured from asbestos or any asbestos related products 2 1 General safety It is th...

Page 4: ...Note Since the appliance is a source of heat circulation of air occurs Therefore it is of importance that you do not use the appliance shortly after a renovation of the home Because of the natural circulation of air moist and volatile components from paint building materials carpet etc will be attracted These components can settle themselves down onto cold surfaces in the form of soot As on all he...

Page 5: ...e min 1000 mm2 Always supply the appliance with a DC convection set The plaster of the outside has to be resistant to a high temperature Use therefore the plaster materials especially made for this such as Masterboard or Fibrelux to prevent discoloring min 100 degrees temperature resistant If the appliance is to be fitted against a wall with combustible cladding the cladding must be removed from t...

Page 6: ...f the flue system must be 3 meters The flue most have a positive updraught The flue must not be used for any other appliance or application Any chimney damper or restrictor should be removed If removal is not possible they must be secured in the fully open position If the appliance is intended to be installed to a chimney which was previously used for solid fuel the flue must be swept clean prior ...

Page 7: ...pliance case Openings are at the back and right side 6 The gas connection is nut and olive suitable for 8 mm pipe 7 Where a gas pipe passes through a void wall or cavity it must be fully enclosed in a sleeve A C B gas supply routes when fire is fitted in a deep surround C Through wall Pipe must be sleeved and sealed to fire A B Behind surround Sleeve pipe through surround inner wall outer wall cav...

Page 8: ...iance is placed on a combustible floor then a fibrelux or similar heatproof board of 12 mm thickness should be placed under it Any under floor vents or openings within the builders opening should be sealed off 3 The surface of the floor must be sufficiently flat to enable the bottom of the front surround and door to be aligned horizontally 4 The front face of the fireplace should be reasonably fla...

Page 9: ... are no fingerprints on the glass It is not possible to remove those prints after you burn the appliance for a while they are burnt in Place the glass in front of the appliance and fix the glass frame or use the glass clamps 15 Place the door and front 4 3 Fitting the firebox continuing 6 Secure the vent connector unit to the flue pipe or chimney liner The flue connector outer collar is for connec...

Page 10: ...e rear log Ensure that the pilot burner remains visible after installation of the log set When not placing the log set correctly the flames tend to burn to the front against the window fig 11 Silva log set lay 4 4 Placing the log set continuing 4 4 2 Model Spectra flatfibre burner The log set consists of a rear log which is permanently attached to the combustion chamber and four logs The logs must...

Page 11: ...reate your own ash bed fig 13 5 REMOTE CONTROL 5 1 Remote control if applicable The remote control is only meant to regulate the flames it functions only when the pilot burner is ignited It is therefore not possible to ignite the appliance with the remote control or to shut off the pilot flame The radio frequency remote control is intended for fireplaces installed in a domestic setting in all EU c...

Page 12: ...k if you can hear a sound and the motor runs when you push a button on the remote control fig 15 UK IRL 6 COMMISSIONING functional checks 6 1 Check pilot ignition 1 Push in and turn the control knob A anticlockwise to the setting small flame You will hear a tick meaning there is ignition Hold the knob in and wait for a few seconds while the air is purged 2 Bring the knob back in the start position...

Page 13: ... is faulty the hot flue gasses will pass over and actuate a heat sensitive switch which will shut off the gas supply This monitoring system TTB must not be adjusted bypassed or put out of operation This TTB or any of its parts must only be exchanged using Faber International authorised parts fig 17 UK IRL smoke match 6 5 Check reference pressure The appliance is preset to give the correct heat inp...

Page 14: ...t routine servicing at regular intervals It is recommended that the fire is inspected serviced by a competent person at least once a year Important Turn off the gas supply before commencing any servicing Always test for gas soundness after refitting the appliance 8 1 Routine annual servicing 1 Clean if necessary the pilot system the burner the combustion chamber the glass 2 Check the log lay and r...

Page 15: ...ss This can be removed with a special non abrasive ceramic glass cleaner ceramic cook top cleaner as follows 1 Remove the door or front as described at 4 2 2 Clean the glass Handle the glass with clean hands wear gloves if possible 3 To fit the glass proceed in reverse order Make sure that the log set has been installed correctly before fixing the glass Attention Before placing the glass check the...

Page 16: ... burner tray and remove the burner Unscrew the injector from the burner inlet Replace and re assemble in reverse order A Governor B Adjusting screw pilot flame C Inlet pressure test point D Burner pressure test point C D D C A B B A fig 23 8 1 6 Burner tray assembly flatfiber burner 1 Remove the front glass and log holder if applicable 2 Break the gas supply at the control valve 3 Remove the cable...

Page 17: ...3089 Motor remote control 37003086 37003086 37003086 Pilot assembly 20900155 20900155 20900145 Thermo couple 37002041 37002041 37002041 Embers 20900019 20900019 20777300 TTB 110 37006055 37006055 37006055 Black spray for combustion chamber 09000008 09000008 09000008 Touch Latch assembly 28103900 INDEX 1 LIST OF SPARE PARTS UK IRL 8 1 9 Combustion test A BS7967 combustion analysis check should be c...

Page 18: ... 70 3 x 1 00 1 x 1 60 Reduced input restrictor mm 1 6 1 6 1 8 1 3 Pilot assembly Type SIT 145 SIT 145 SIT 160 SIT 160 Code Nr 30 Nr 30 Nr 51 Nr 30 Flue Flue size mm 100 100 100 100 Min flue height m 3 3 3 3 Gas control GV36 C5AOEHC68M GV36 C5AOEHC68M GV36 C5AOEHC68M Remote control Transformer 230 VAC 50Hz 5VA 230 VAC 50Hz 5VA 230 VAC 50Hz 5VA Voltage transformer 4 5 V 4 5 V 4 5 V Batteries remote ...

Page 19: ...n starting the appliance and increase the life time of the appliance 9 SAFETY INSTRUCTIONS FOR THE USER 9 1 General safety instructions If a gas leak is found or suspected turn off the gas supply at the meter and contact your installer or gas emergency service These instructions should be read carefully and retained for future reference Do not use the fire with a broken or damaged glass The fire h...

Page 20: ...pilot should remain alight 4 Turn the control knob A to the position 5 Turn knob B slowly anticlockwise the fire should then ignite 6 Adjust flames to the required level 10 CONTROLLING THE APPLIANCE 10 1 Lighting the fire If the main burner or pilot light are extinguished for any reason do not attempt to relight the pilot within 5 minutes Contact a qualified installer when the appliance goes off r...

Page 21: ...wise to position 2 To enable knob B turn knob A to the position 3 To extinguish the pilot turn control knob A to position although it is in order lo leave the pilot permanently lit 10 3 1 When the pilot extinguishes Warning When the pilot extinguishes for whatever reason you should wait at least 5 minutes before trying to turn it on again Possible causes of pilot extinguish are Operating error Int...

Page 22: ...iver has to learn the code from the transmitter which is already done at the factory However the code disappears if the receiver is disconnected from the mains for a longer period 1 Push the mod button on the receiver and hold it for 3 seconds 2 The green control lamp will light up and stay on Repeat this step if not 3 Push a button on the remote control The control lamp on the receiver should now...

Page 23: ...sponsibly and in conformity with government regulations Remove the batteries before disposing of the remote control Information on how to responsibly dispose of discarded appliances can be obtained from the local authorities 11 CLEANING AND SERVICE INSTRUCTIONS Important Turn off the fire and allow it to cool down before commencing cleaning It is recommended that the fire is inspected serviced by ...

Page 24: ...Bedienungs und Installationsanleitung Einbau Gasofen 40 010 506 01 23 SILVA B11 Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501 ...

Page 25: ...ets 11 6 SERVICE 12 6 1 Demontable Teile 12 6 2 Regelarmatur 14 7 BEDIENUNG 15 7 1 Handbedienung 15 7 2 Zündbrenner 15 7 3 Hauptbrenner 16 7 4 Fernbedienung wenn zutreffend 16 8 WARTUNG UND REINIGUNG 20 8 1 Reinigung des Brenners 20 8 2 Reinigung der Sichtscheibe 20 8 3 Reinigen der Zierleiste 20 9 STÖRUNG 21 10 ENTSORGUNG DER VERPACKUNG UND DES GERÄTES 22 ANLAGE 1 Ersatzteilliste Silva B11 23 ANL...

Page 26: ...alten Sie eine Bedienungs und Installationsanleitung Außer Informationen über den Gebrauch enthält Sie auch Ratschläge über Sicherheitsvorkehrungen und Wartung und Pflege des Gerätes Diese Anleitung ist in den Sprachen Deutsch Englisch Französisch und Niederländisch verfügbar Bei der Zusammenstellung der Bedienungs und Installationsanleitung wurde davon ausgegangen dass der Ofen von einem anerkann...

Page 27: ...teil bei vorhandener Fernbedienung auszuschalten Kinder dürfen die Fernbedienung nur unter Aufsicht betätigen 3 SICHERHEITSANWEISUNGEN Das Gerät muss von einem anerkannten Installateur gemäß Installationsanweisung des Herstellers und den geltenden Vorschriften des Landes und vor Ort aufgestellt angeschlossen und kontrolliert werden Das Gerät muss vom Installateur auf Dichte des Gas und Verbrennung...

Page 28: ...rschließen Sie mögliche Konvektionsöffnungen an der Oberseite des Gerätes Achtung Benutzen Sie rund um den Ofen nur hitzebeständige Materialien Nicht hitzebeständige Materialien können sich verfärben 4 VORBEREITUNG 4 1 ANSCHLUSS AN DIE GASLEITUNG Sorgen Sie für einen Gasanschluss G3 8 mit einem den ICE Vorschrif ten entsprechenden Absperrhahn G1 2 in der Zuleitung Achten Sie darauf dass die Regelg...

Page 29: ... Rohrmundes ist jetzt mit dem Innenteil verbunden 6 Drehen Sie die Klemmplatte mit der Lasche nach unten und schieben Sie die Klemmplatte zwischen die Führungschienen so dass die Endstücke den Rohrmund umschließen siehe Abb 6 Sorgen Sie dafür dass die Rohrmundplatte auf das Innenteil gedrückt wird Abb 5 Abb 6 4 4 VORBEREITENDE ARBEITEN 1 Nehmen Sie den Ofen aus der Verpackung 2 Öffnen Sie die Tür ...

Page 30: ...e anderen Holzblöcke wie in der Zeichnung angegeben ein Bevor das Glas definitiv eingesetzt wird ist das Flammenbild zu kontrollieren Abb 10 Einlegen des Holzsets 7 Verbinden Sie das TRS Kabel mit der TRS Einrichtung siehe Abb 7 8 Sorgen Sie für einen vorschriftsmäßigen Gasanschluss siehe Gasanschluss 9 Kontrollieren Sie alle Gasanschlüsse auf Gasdichte Benutzen Sie hierzu Seifenlauge und oder ein...

Page 31: ...r durch das von FABER International angegebene Modell ersetzt werden A B C D fig 12 Zündflammeneinheit 6 SERVICE 6 1 DEMONTABLE TEILE 6 1 1 Demontage und Montage des Brenners A Zündflammeneinheit B Einspritzbegrenzung C Bodenplatte D Regelblock E Empfangsteil F Befestigungsbügel Demontage 1 Schließen Sie den Gashahn 2 Entfernen Sie das Glas und den Holzsatz 3 Koppeln Sie die Brennerleitung ab 4 Ne...

Page 32: ...halter fünf bis zehn Sekunden gedrückt Drehen Sie den Schalter jetzt nach rechts auf Großstellung große Flamme Wenn die Dauerzündflamme nicht zündet sind diese Schritte bis zum Zünden der Flamme zu wiederholen 7 2 2 Ausschalten Drehen Sie den Schalter A nach 7 2 3 Erlöschen der Dauerzündflamme Warnung Sollte die Dauerzündflamme aus welchen Gründen auch immer erlöschen warten Sie bitte unbedingt 5 ...

Page 33: ... sind Bedienungsfehler Einschalten der Sicherung durch schlechten Schornsteinzug Fehler im Zündbrennersystem Bei wiederholten Problemen bitte Installateur informieren 7 3 HAUPTBRENNER 7 3 1 Anzünden Zünden Sie die Zündflamme und drehen Sie Schalter A auf große Flamme Stellen Sie jetzt mit dem Bedienungsschalter B die Stellung des Brenners zwischen Klein und Großstellung ein 7 3 2 Ausschalten Durch...

Page 34: ...klemme in der Fernbedienung fest und schließen Sie den Deckel Achtung Batterien sind chemischer Abfall und sind nach den geltenden örtlichen Vorschriften gesondert zu entsorgen 6 Drücken Sie die MOD Taste auf dem Empfangsteil des Ofens und halten Sie diese Taste ein paar Sekunden gedrückt Die Kontrollampe leuchtet kontinuierlich Wiederholen Sie diesen Schritt wenn dies nicht der Fall sein sollte 7...

Page 35: ...r Sie das Fenster wieder einsetzen 8 3 REINIGEN DER ZIERLEISTE Die Zierleiste wird mit einem trocknen Tuch gereinigt Flecken sind mit einem hitzebeständigen Reinigungsmittel zu entfernen Durch Verwendung von nicht hitzebeständigen Reinigungsmitteln kann sich die Zierleiste verfärben 9 STÖRUNG STÖRUNG Ofen geht nicht an oder aus Schlechte Verteilung der Flammen ABHILFE Entlüften Kontrollieren Sie o...

Page 36: ...rs 20 g verpackt 20900019 12 TRS Satz 110 20900036 13 Zündflammensatz 20900046 Anlage 1 DE DE 22 10 ENTSORGUNG DER VERPACKUNG UND DES GERÄTES Die Verpackung des Gerätes kann recycelt werden Die Verpackung kann folgende Bestandteile enthalten Pappe FCKW freier Schaumstoff weich Holz Kunststoff Papier Diese Materialien sind umweltgerecht und den behördlichen Vorschriften entsprechend zu entsorgen Ba...

Page 37: ...5 15 15 15 15 15 15 15 15 15 15 15 15 15 gaz de combustion temp 250 250 250 250 250 250 250 250 250 250 250 250 250 250 Aansluiting rookgasafvoer flue collar Abgasanschluss raccord de l évacuation du gaz fumée 100 mm 100 mm 100 mm 100 mm 100 mm 100 mm 100 mm 100 mm 100 mm 100 mm 100 mm 100 mm 100 mm 100 mm Regelblok control block Regelblock bloc de réglage Maxitrol GV36 Maxitrol GV36 Maxitrol GV36...

Reviews: