Air Quality Wireless Datalogger Panel

E2230

User Manual

Summary of Contents for E2230

Page 1: ...Air Quality Wireless Datalogger Panel E2230 User Manual...

Page 2: ...iption 4 Safety requirements 4 Operating conditions 5 Installation guidelines 5 Mounting dimensions 7 Operation 8 Modbus RTU Communication 15 RS485 communication interface 15 Communication parameters...

Page 3: ...0 C 400 9 999 ppm CO2 Resolution 0 1 RH 0 1 C 1 ppm CO2 Accuracy 2 5 RH 0 3 C 50 ppm CO2 3 of reading Response time 120 seconds Power supply 9 VDC 90 265 VAC adapter Power consumption 6 W Digital inte...

Page 4: ...nary or mobile devices Bright LED displays provide easy direct monitoring Additional features include real time clock and calendar Safety requirements Misuse will impair the protection of the product...

Page 5: ...and vibrations Avoid corrosive atmosphere and areas highly contaminated with dust oil mist etc Keep the instrument away from direct sunlight A sudden temperature or humidity change might affect the se...

Page 6: ...E2230 Rev 09 03 2021 Mains power adapter included Dimensions 67 x 44 x 44 mm cable 1 2 m 9 W 9 VDC 1 A connector 5 5 2 1 mm 6...

Page 7: ...E2230 Rev 09 03 2021 Mounting dimensions Dimensions Front view Back view 7...

Page 8: ...will read out logger internal memory and shall confirm memory validation This process can take up to 10 seconds depending on how much data has been saved After these procedures logger shall start ind...

Page 9: ...ed to the Hotspot then device IP is 192 168 4 1 This can also be seen if you look at the connection settings of your device which is used for connecting This picture shows the connection settings of t...

Page 10: ...E2230 Rev 09 03 2021 Main page After navigating to the device the device measurement status page will open 10...

Page 11: ...or stationary logging into the chart AP WiFi configuration Hotspot configuration and data sending configuration STA WiFi configuration Available WiFi network connectivity configuration Network informa...

Page 12: ...Information page If DHCP was not selected the user can navigate to the device within the local WiFi network by its assigned IP address Note Manually assigning IP addresses to the device should be done...

Page 13: ...of 4 bytes c Register 414 Last Temperature record d Register 415 Last Humidity record e Register 416 Last CO2 record f Register 417 Last logged data YEAR g Register 418 Last logged data MONTH h Regis...

Page 14: ...er 280 Writing 42330 will clean internal memory of the device and will reboot the device Register 430 CO2 ABC period days default 14 Register 432 CO2 ABC baseline value ppm default 430 ppm Register 43...

Page 15: ...registers 06 Write a single register Error codes 01 Illegal function 02 Illegal data address 03 Illegal data value 04 Slave device failure details of last error 04 can be read from register 0x0008 Mo...

Page 16: ...ng stop memory overwritten bit 0 0 bit 1 1 bit 2 0 1 Circular memory off on bit 3 0 bit 4 0 bit 5 0 1 Logging stopped due to memory full bit 6 0 bit 7 0 bit 8 1 0 Indication or logging mode Configurat...

Page 17: ...of 4 bytes 414 40415 R Last temperature record 415 40416 R Last humidity record 416 40417 R Last CO2 record 417 40418 R Last logged data YEAR 418 40419 R Last logged data MONTH 419 40420 R Last logged...

Page 18: ...nufacturer will at its option either repair or replace a product that proves to be defective This warranty is void if the product has been operated in conditions outside ranges specified by the Manufa...