background image

Part Number: 7192M1200-1.0.1 Rev: D

Released: 2019-06

Irideon WLZ

User Manual

Version 1.0

Summary of Contents for Irideon WLZ

Page 1: ...Part Number 7192M1200 1 0 1 Rev D Released 2019 06 Irideon WLZ User Manual Version 1 0 ...

Page 2: ...rademarks and patents go to etcconnect com ip All other trademarks both marked and not marked are the property of their respective owners ETC intends this document whether printed or electronic to be provided in its entirety ...

Page 3: ...ring DMX variant 6 Install the Mounting Plate and Complete the Wiring DMX variant 8 Install Canopy Fixture 0 10 V and DALI variants 10 Install Portable Fixture with C clamp 13 Install Portable Fixture on Unistrut Track 14 Connect Cables to Portable Fixture 14 Portable Fixture DMX Pinout 15 Set the DMX Address on the Fixture 15 Alternative DMX Addressing Functions 17 Adjust the Local Intensity 17 I...

Page 4: ...djustments 19 Set the Angle with the Yoke 19 Adjust the Field 19 Use the Barn Door Accessory 20 Use the Integrated Media Holder 20 Install Color Media or Diffusion 21 Install Dichroic Glass 21 Clean the Lens 22 RDM Values 23 ...

Page 5: ...system Portable Includes a miniature C clamp and yoke mounted driver and has a permanently installed power cord with 3 prong Edison connector Region specific connectors are available Contact ETC for available options Use L5 15 plugs on branch circuits with L5 15 receptacles only Canopy Available in three different control variants 0 10 V DALI DMX Note The miniature C clamp for the portable fixture...

Page 6: ...all national and local electrical and construction codes and regulations WARNING Use the track mount fixture with ceiling mounted track only WARNING To reduce the risk of fire and electric shock use the track mount fixture only with the DataTrack EUTRAC track system AVERTIR Pour éviter le risque d incendie ou de choc électrique avec le modèle adaptateur pour rail utiliser uniquement avec une alime...

Page 7: ...options Track mount and portable 100 240 V 50 60 Hz Canopy 0 10 V and DALI 120 277 V 50 60 Hz Canopy DMX 100 277 V 50 60 Hz Portable fixture 6 ft power cable hard wired to fixture with mains connector options of NEMA 5 15P Schuko or UK Inrush first half cycle for 0 10 V and DALI canopy fixtures 120 V 2 A 240 V 5 A 277 V 6 A Inrush first half cycle for all other fixtures 120 V 11 A 240 V 24 A 277 V...

Page 8: ... place 3 Use the circuit selection lock to select the circuit The desired circuit number should point toward the center of the adapter WARNING When using the circuit selection lock ensure that the selected circuit is a constant power circuit Dialing into a dimmable circuit may cause fixture damage that will void the ETC warranty Yoke Integrated media holder Illustration shows fixture body only Wid...

Page 9: ...e backbox with the provided screw separating the power side from the data side see image at right Note The canopy fixture can be installed directly on 4 and 4 11 16 backboxes or on backboxes with round cover plates The canopy fixture cannot be installed on 1 gang backboxes or trim rings CAUTION DMX control is a Class 2 circuit DMX wiring cannot be run through the same conduit as line voltage power...

Page 10: ...ng surface is smaller than the canopy enclosure 3 Terminate DMX RDM input from the control source to the backbox If using Belden 9729 a See the DMX Cable Preparation for Screw Termination Setup Guide for instructions to prepare and terminate Belden 9729 for DMX input cable to the screw terminal connector b Install the screw terminal connector with wires terminated to the DMX RDM Input receptacle o...

Page 11: ...X RDM devices can be daisy chained together per data run a See the specific termination setup guide for the type of cable used either Belden 9729 or Category 5 in the installation Termination kits are ordered separately b Install the connector with wires terminated to the DMX RDM Thru receptacle on the termination board 5 Connect the building ground wire to the power block on the fixture 6 Followi...

Page 12: ...at the power side and data side are separated by the voltage barrier in the backbox See Install the Voltage Barrier DMX variant on page 5 For this structure secure mounting plate using 4 11 16 backbox Large oval slots see 1 above 4 backbox Small oval slots see 2 above Mounting plate Canopy screws Mounting plate screws Cover plate if needed for surface mounting DMX variant shown Canopy screw hole M...

Page 13: ...ure to the mounting plate CAUTION Make sure that the wiring is clear of the mounting plate before you secure the fixture Hook 2 Use the hook in the canopy enclosure to hang the fixture from the mounting plate while you complete the fixture wiring 3 If desired manually set the DMX address on the fixture using the three addressing dials in the canopy See Set the DMX Address on the Fixture on page 15...

Page 14: ...rior of the canopy enclosure could be exposed after installation with only the mounting plate the mounting surface is smaller than the canopy enclosure Note The 0 10 V driver conforms to IEC 60929 Annex E Of the 0 10 V range use 0 1 V to set the minimum level and use 1 10 V for continuous dimming Note The canopy fixture can be installed directly on 4 and 4 11 16 backboxes or on backboxes with roun...

Page 15: ...d the white wire to neutral For 230 V fixtures Connect the brown wire to line and the blue wire to neutral 6 Connect the data wires to the fixture wiring using the included WAGO connectors For 0 10 V fixtures Connect the gray wire to data and the purple wire to data For DALI fixtures Connect the purple wires to data and data For this structure secure mounting plate using 4 11 16 backbox Large oval...

Page 16: ... canopy screws to secure the fixture to the mounting plate 8 Insert the oval shaped covers into the canopy enclosure to cover the canopy screw openings 9 Restore power at the disconnect device Canopy screws Oval shaped covers ...

Page 17: ...hen tighten the pipe bolt to secure it Use the standard pipe bolt to secure the fixture to larger mounting pipes If necessary exchange the standard pipe bolt for the longer pipe bolt included to secure the fixture to smaller mounting pipes Note The miniature C clamp is available only in non EU markets Within the EU use an M12 bolt to secure a C clamp provided separately to the fixture CAUTION Tigh...

Page 18: ...as needed To order RJ45 to female XLR adapter use part number W6538 To order RJ45 to male XLR adapter use part number W6539 2 Connect the fixture to the power source Note The Irideon WLZ is not self terminating You must terminate the last fixture in line with a 120 Ohm resistor Please contact your ETC customer service representative to purchase part number N4086 No more than 32 DMX devices can be ...

Page 19: ... via RDM or locally on the fixture There are three addressing dials on the track adapter track mounted fixture in the canopy canopy fixture or on the driver box portable fixture To set the DMX address use a small flat head screwdriver to move the arrow to the desired address number Pin Wire Color Description 1 White orange DMX1 2 Orange DMX1 3 White green DMX2 4 Blue Not Connected 5 White blue Not...

Page 20: ...s ETC recommends connecting no more than 20 fixtures on a single run 3 2 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 Local intensity control knob Status LED and DMX addressing dials Portable Track mount 1 S 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 1 S 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 10 S 100 S 10 S 100 S Canopy mounting plate removed In th...

Page 21: ...ntrol is located on the side of the canopy next to the status LED To adjust the local intensity knob on the canopy fixture you will need a small flat head screwdriver jeweler s screwdriver You can adjust the local intensity with or without DMX being present When DMX is not present you can control the intensity When DMX is present you can set the maximum light output Dimming will be proportional in...

Page 22: ...on for 10 seconds and then it turns off When the local intensity is set to Off the status LED will flash when there is a loss of DMX With the local intensity set to any other position the status LED will flash for 10 seconds when there is a loss of DMX Then the LED will turn off Note Changing the address via RDM will override the local DMX addressing dials However if you change the addressing dial...

Page 23: ...d position 3 Tighten the yoke locking knob to secure the position Adjust the Field Rotate the back of the fixture body to adjust the field between wide and narrow see image at right The field angle markers on the side of the fixture indicate the field angle as you adjust within the range of 16 91 degrees Yoke locking knob Field angle markers ...

Page 24: ...r media often referred to as gel or diffusion in front of the lens The media holder is equipped with a magnetic retaining clip that prevents the media from falling out The integrated media holder can take color media diffusion or dichroic glass with a 2 11 16 69 mm diameter ETC provides a diffuser to create additional diffusion for a super soft beam To use this accessory order part number 7192A402...

Page 25: ...lder with the inset on the front casting Install Dichroic Glass The integrated media holder accommodates 1 75 mm thickness dichroic glass 1 Release the magnetic retaining clip by gently pushing it up 2 Place the dichroic glass into the groove 3 Replace the media holder by aligning the tab at the top of the media holder with the inset on the front casting Integrated media holder Dichroic glass Magn...

Page 26: ... side of the lens is facing out 7 Replace the front casting and secure it with the screws 8 Replace the integrated media holder WARNING Do not use ammonia based or other harsh commercial cleaners Clean lens only as directed Commercially available glass cleaning agents should be avoided as they may contain ammonia other harsh chemical detergents or abrasive agents These cleaners may damage the lens...

Page 27: ...nufacturer ID 0x6574 Electronic Theatre Controls Model ID 0x901 Irideon WLZ Parameter RDM PID Value DMX Start Address 0x00F0 Range 1 512 Personality ID 0x00E0 1 DMX 2 Local Output Frequency 0x8123 0 Standard 1 2 kHz 1 High 25 kHz ...

Page 28: ...2 2799 1220 Paris FR 33 1 4243 3535 Web etcconnect com Support support etcconnect com Contact etcconnect com contactETC 2019 Electronic Theatre Controls Inc Product information and specifications subject to change ETC intends this document to be provided in its entirety Trademark and patent info etcconnect com ip 7192M1200 1 0 1 Rev D Released 2019 06 ...