background image

 

Art. No. 11355  

 

 

 

All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of 
ESERA GmbH. Errors and technical modification subject to change. 



ESERA GmbH, ESERA-Automation 2020 

www.esera.de 

11355 V2.0 R1.0  Manual 

Page 1 of 5 

 

User Guide 

1-Wire Term 1 Modul 

Termination for 1-Wire Bus system 

 
 

Performance characteristics 

 

Active termination for 1-Wire Bus 

 

Small housing 44 x 44 x 25 mm for wall or  

flush mounting 

 

screw terminals  

 

Display for Power and Activity (Data) 

 

Termination for all 1-Wire Network sizes 

 

No software required 

 

Simple installation 

 
 
 
 

 

 
 
 
 

Introduction 

Before you start mounting the 1-Wire Term 1 module and putting the device into operation, read these operating 
instructions carefully until the end, especially the section of the safety instructions. 
 

Product description 

In a 1-Wire network, the 1-Wire Term 1 ensures a defined termination at the end of the 1-Wire network and thus a 
stable and professional 1-Wire network. The 1-Wire Term 1 is thus a basic component of the 1-Wire network.  
 
Active termination (1-Wire Term 1) is highly recommended for increasing the maximum line length and 
improving the system stability of the 1-Wire network, especially with long 1-Wire lines and with a setup in star 
or tree topology. 
In a 1-Wire network up to 3 pieces of 1-Wire Term 1 modules can be connected. The 1-Wire Term 1 is very 
compact and can be ideally installed in a flush-mounted box. 
A 1-Wire network should be terminated at the beginning and at the end (like many other bus systems). This 
task is fulfilled by the 1-Wire Controller / 1-Wire Gateway or 1-Wire Bus Coupler at the beginning of the 1-
Wire network and the 1-Wire Term 1 at the end of the line. The use of 1-Wire Term 1 prevents reflections at 
the cable ends and thus ensures increased system stability of the entire 1-Wire network. 
The 1-Wire Term 1 contains a passive and an active terminating resistor for an optimized termination of all 1-
Wire network sizes. The module has an operating voltage and activity display via LEDs. It is designed for 
installation in 1-wire networks with standard 3-wire system (GND, 1-wire data and 5 V). 
The 1-Wire Term 1 module has overvoltage and reverse polarity protection of the operating voltage and 1-
Wire data line. 
 

Size comparison 

Summary of Contents for 1-Wire Controller 1

Page 1: ... the 1 Wire network Active termination 1 Wire Term 1 is highly recommended for increasing the maximum line length and improving the system stability of the 1 Wire network especially with long 1 Wire lines and with a setup in star or tree topology In a 1 Wire network up to 3 pieces of 1 Wire Term 1 modules can be connected The 1 Wire Term 1 is very compact and can be ideally installed in a flush mo...

Page 2: ...ESD EN 61000 4 3 HF EN 61000 4 4 Burst EN 61000 4 5 Surge EN 61000 6 1 interference immunity EN 61000 6 3 interference radiation RoHS 7 Integration in 1 Wire Network The 1 Wire Term 1 module is mounted at the end of a 1 Wire network cable If the 1 Wire network is star shaped i e with several 1 Wire cable sections a 1 Wire Term 1 module should be connected to each end No more than three 1 Wire Term...

Page 3: ... the written consent of ESERA GmbH Errors and technical modification subject to change ESERA GmbH ESERA Automation 2020 www esera de 11355 V2 0 R1 0 Manual Page 3 of 5 8 Connection example Note Basics and tips for the 1 Wire bus system can be found in our eBook in the shop at https www esera de service support 1 wire grundlagen ...

Page 4: ...aste Electrical and Electronic Equipment 12 Safety instructions When using products that come into contact with electrical voltage the valid VDE regulations must be observed especially VDE 0100 VDE 0550 0551 VDE 0700 VDE 0711 and VDE 0860 All final or wiring work must be carried out with the power turned off Before opening the device always unplug or make sure that the unit is disconnected from th...

Page 5: ...affected If defects occur for which the ESERA GmbH is responsible and in the case of replacement goods the replacement is faulty the buyer has the right to have the original purchase price refunded or a reduction of the purchase price ESERA GmbH accepts liability neither for the constant and uninterrupted availability of the ESERA GmbH or for technical or electronic errors in the online offer We a...

Reviews: