background image

Instruction manual

0464 547 001 GB 20171106

Valid for: Serial no: 648-xxx-xxxx

WeldCloud™ Mobile

Summary of Contents for WeldCloud Mobile

Page 1: ...Instruction manual 0464 547 001 GB 20171106 Valid for Serial no 648 xxx xxxx WeldCloud Mobile ...

Page 2: ......

Page 3: ...DUCTION 6 2 1 Equipment 6 3 TECHNICAL DATA 7 4 INSTALLATION 8 5 OPERATION 10 5 1 Connections and control devices 10 5 2 Startup sequence 11 6 MAINTENANCE 12 6 1 Inspection and cleaning 12 7 ORDERING SPARE PARTS 13 DIAGRAM 14 ORDERING NUMBERS 15 ACCESSORIES 16 Rights reserved to alter specifications without notice ...

Page 4: ...ty precautions must meet the requirements that apply to this type of equipment The following recommendations should be observed in addition to the standard regulations that apply to the workplace All work must be carried out by trained personnel well acquainted with the operation of the equipment Incorrect operation of the equipment may lead to hazardous situations which can result in injury to th...

Page 5: ... is provided by the public low voltage supply system There may be potential difficulties in ensuring electromagnetic compatibility of class A equipment in those locations due to conducted as well as radiated disturbances NOTE Dispose of electronic equipment at the recycling facility In observance of European Directive 2012 19 EC on Waste Electrical and Electronic Equipment and its implementation i...

Page 6: ...h interface to enable connection to a Bluetooth device for example a Bluetooth enabled bar code scanner WeldCloud Mobile can be used with power sources that are fitted with a W82 control unit or a PEK control panel 2 1 Equipment WeldCloud Mobile is supplied with An instruction manual A control cable for connection to a W82 control unit or to a PEK control panel Two Ethernet cables for connection t...

Page 7: ...y voltage from power source through W82 32 50 V AC 50 60 Hz Weight 2 15 kg 4 74 lb Dimensions l w h 205 135 189 mm 8 07 5 31 7 44 in Enclosure class IP23 Enclosure class The IP code indicates the enclosure class i e the degree of protection against penetration by solid objects or water ...

Page 8: ...ct the control cable from the Internal CAN on the W82 control unit to the CAN connector on the WeldCloud Mobile 3 Connect the Ethernet cable from the W82 control unit to LAN port 1 on the WeldCloud Mobile 4 Optional if not using Wi Fi or 3G Connect an Ethernet cable from the LAN connector 2 on the WeldCloud Mobile to external LAN Make sure not to clamp the Ethernet cable with power cables or weldi...

Page 9: ...from the W82 control unit as shown to the left in the illustration below To attach Put the WeldCloud Mobile straight down on the W82 control unit as shown to the right in the illustration below Make sure that the Dual Lock fastener stems are completely fitted Install WeldCloud Mobile with PEK Contact your service center for guidance for the specific system configuration ...

Page 10: ... LED Indicates that there is power to the WeldCloud Mobile 4 LAN connector 2 Ethernet port 2 used for external connections 5 CAN connector male Used to provide power supply to WeldCloud Mobile and to connect the control cable to the W82 control unit or to the PEK control panel 6 CAN connector female Used for communication with ESAB wire feed unit 7 LAN connector 1 Ethernet port 1 used to connect t...

Page 11: ... there are no detected problems A steady lit red LED after start up sequence indicates that the configuration file is corrupt or that there is an error on the equipment or network parameter Red LED blinking short short signal indicates no connection to WeldCloud short long long signal indicates no connection with W82 or PEK Combination of both blinking is possible C Wi Fi operation The Wi Fi is en...

Page 12: ...authorised personnel may remove the safety plates CAUTION All warranty undertakings from the supplier cease to apply if the customer attempts any work to rectify any faults in the product during the warranty period 6 1 Inspection and cleaning Regularly check that the control unit is in electrical contact with the power source and that the connections are fault free and correctly connected ...

Page 13: ...rvice unit which has carried out the service or repair work to make sure that the product still conforms to the mentioned standards Spare parts and wear parts can be ordered through your nearest ESAB dealer see the back cover of this document When ordering please state product type serial number designation and spare part number in accordance with the spare parts list This facilitates dispatch and...

Page 14: ...DIAGRAM 0464 547 001 14 ESAB AB 2017 DIAGRAM ...

Page 15: ... Wired LAN 3G Bluetooth communication GPS functionality 0463 450 01 Instruction manual WeldCloud WeldCloud software 0463 391 001 Spare parts list WeldCloud Mobile 0740 800 203 Service manual W82 Retrofit Mig 4004i WeldCloud WeldCloud Mobile Instruction manuals and the spare parts list are available on the Internet at www esab com ...

Page 16: ...ACCESSORIES 0464 547 001 16 ESAB AB 2017 ACCESSORIES 0456 527 885 Control cable connectors included 0 45 m 12 poles 0465 816 001 Ethernet cable connectors included 0 5 m industrial ...

Page 17: ...ACCESSORIES 0464 547 001 17 ESAB AB 2017 ...

Page 18: ...e Henares MADRID Tel 34 91 878 3600 Fax 34 91 802 3461 SWEDEN ESAB Sverige AB Gothenburg Tel 46 31 50 95 00 Fax 46 31 50 92 22 ESAB International AB Gothenburg Tel 46 31 50 90 00 Fax 46 31 50 93 60 SWITZERLAND ESAB Europe GmbH Baar Tel 41 1 741 25 25 Fax 41 1 740 30 55 UKRAINE ESAB Ukraine LLC Kiev Tel 38 044 501 23 24 Fax 38 044 575 21 88 North and South America ARGENTINA CONARCO Buenos Aires Tel...