Magnetic Gate Lock Installation Manual

Magnetic Gate Lock Installation Manual

SECO-LARM U.S.A., Inc.

ACCESSORIES

E-942F-1K3/ZQ

 - “Z” bracket for E-942FC-1K3Q

E-942F-1K3/LQ

 - “L” bracket set for E-942FC-1K3Q

• For use with nearly all types of outdoor sliding and swinging electric gates.
• Holding force — 1,300 pounds (591kg).
• Can be mounted horizontally or vertically.
• Housing dimensions — 8" x 2

1

/

2

" x 1

5

/

8

" (203 x 63 x 41 mm).

• Armature plate dimensions — 7

1

/

4

” x 2

3

/

8

” x 

5

/

8

” (185 x 61 x 16 mm).

• Voltage — 12VDC or 24VDC, with current draw of 500mA at 12VDC (250mA @ 24VDC).
• Cable — 6’ (2 meter), with standard conduit connector (3/4” outside diameter, 1/2” inside diameter).

MOUNTING THE E-942FC-1K3Q

A. Determine type of gate:

1.

Single-swing gate

 (fig. 2) — Gate swings on one end, and comes to rest on a fixed gate post when closed. In this

case, a typical installation has the electromagnet fixed to the gate post, and the armature connected to the free end
of the gate with a Z-bracket.

2.

Double-swing gate

 (fig. 3) — Two gates swing in the same direction when activated. The electromagnet is fixed

to the free end of one gate, and the armature is fixed to the free end of the other via a Z-bracket.

IMPORTANT:

a. A cover piece should be added to the Z-bracket to cover the electromagnet. This will help prevent unauthorized

users from prying the armature and the electromagnet apart.

b. Because of the cover piece, it is important to coordinate the swing of the gates to prevent the electromagnet

from catching on the cover piece. In this case, the gate with the armature should open before the gate with the
electromagnet.

3.

Sliding gate

 (fig. 4) — The gate slides instead of swings away from a fixed gate post. In this case, use L-brackets

to mount the electromagnet and the armature perpendicular to each other.

B. Mount the electromagnet (fig. 5) — In most cases, the position of the electromagnet will determine the location of the

armature plate. Make sure there is space to run the cable.

C. Mount the armature (fig. 5) — Once the electromagnet is mounted, determine the correct position of the armature.

Use the appropriate L-bracket or Z-bracket to position the armature so that it will lay against the electromagnet when
activated. However, leave a slight gap between the two so that the armature does not slam against the electromagnet
when the gate is closed.
1. Put one rubber washer between two steel washers, and place them over the armature screw between the armature

and the bracket.  This will allow the armature to pivot slightly around the armature screw in order to compensate
for gate misalignment.

2. Make sure the guide pins are inserted into guide holes to prevent the armature from spinning.
3. Tighten the sexnut enough so the armature can withstand the force of someone attempting to pry the gate open

while the electromagnet is engaged.

4. Do not tighten the armature against the bracket. The armature must be able to pivot around the armature screw.

Page 1

Page 4

Note: Products with model number that ends with "Q" or have a green “Q” sticker represents RoHS compliant products.

ENFORCER

®

TROUBLESHOOTING

Possible cause:

No power

Poor contact between
electromagnet and
armature plate

Incorrect voltage
setting
A secondary diode was
installed across the
electromagnet

Solutions:

• Check to make sure the wires are secure
• Check that the power supply is connected

and operating

• Make sure the unit is wired correctly
• Make sure the electromagnet and

armature plate are properly aligned

• Make sure the contact surfaces of the

electromagnet and armature plate are
clean and free from rust

• Check the power leads with a meter, and

make sure the correct voltage is present

• The electromagnet is fitted with a metal

oxide varistor to prevent interference, so
do not install a secondary diode

Problem:

Gate does not lock

Gate locks, but can be
easily forced open

Delay in gate releasing

SECO-LARM

SECO-LARM

SECO-LARM

SECO-LARM

SECO-LARM

®

 U.S.A., Inc.

 U.S.A., Inc.

 U.S.A., Inc.

 U.S.A., Inc.

 U.S.A., Inc.

16842 Millikan Avenue, Irvine, CA  92606

Tel: 800-662-0800 / 949-261-2999   Fax: 949-261-7326

Website: www.seco-larm.com

E-mail: [email protected]

WARRANTY:

 

 

 ENFORCER Electromagnetic Locks are warranted against defects in material and

workmanship while used in normal service for a period of one (1) year from the date of sale to the
original customer. Our obligation is limited to the repair or replacement of any defective part if the unit
is returned, transportation pre-paid, to SECO-LARM.

PITLW1

MIE942Fc1K3Q.pmd/0805

NOTICE

The information and specifications printed in this manual are current at the time of publication.
However, the SECO-LARM policy is one of continual development and improvement.  For this reason,
SECO-LARM reserves the right to change specifications without notice.  SECO-LARM is also not
responsible for misprints or typographical errors.
Copyright © 2008 SECO-LARM U.S.A., Inc.  All rights reserved.  This material may not be reproduced
or copied, in whole or in part, without the written permission of SECO-LARM.

REGULAR MAINTENANCE

• Clean the contact surfaces of the electromagnet or armature plate with a soft cloth and non-

abrasive, non-corrosive cleaner.

• Apply a light coat of a silicon lubricant to prevent rust.  Wipe away the excess.
• Check that the armature plate is securely attached to the door, yet can pivot slightly around the

armature screw.

• Check that the electromagnet is securely attached to the door frame.

E-942FC-1K3Q