ENDA EUC942 PID UNIVERSAL CONTROLLER

* 96 x 96mm sized.
* Selectable sensor type.
* Selectable 0-20mA or 4-20mA input.

* Soft-Start.

 

Automatic calculation of PID parameters  (SELF TUNE).

* Selectable Heat/Cool control.

* Communication vai RS-485 ModBus protocol (Optional).

* Selectable 0-20mA or 4-20mA analog control output.
* Relay output can be programmable as second alarm or control output.
* AL1 relay output for first alarm out.

* Input offset feature.
* In the case of sensor failure 

relay state can be 

  selected.
* Panel or ModBus can be done through the control outputs.

periodical running or 

Parameter access protection on 3 levels.

Programming by using keypad or Modbus.

CE marked according to European Norms.

Thank you for choosing ENDA EUC942 universal controller.

* Selectable analog, SSR or relay control output.

 Enter PID parameters of the system if they are known at the beginning.
 Otherwise, Self-Tune should be activated.

AL1

CNT/AL2

AN/SSR

 UNIVERSAL CONTROLLER

EUC 942

ENDA

PV

SV

SET

ASET

CSET

OUTPUTS

 

 Selectable as Control or  Alarm2 output.

 Relay : 250V AC, 2A ( for resistive load), NO/NC.

 Selectable as 0-20mA, 4-20mA analog output or logic control output. 

 

(Alarm1 output).

 Relay : 250V AC, 2A ( for resistive load), NO/NC selectable. 

 AL1

  ANL/SSR  

 Mechanical 30.000.000 operation; Electrical 300.000 operation

  Life expectancy for relay 

 CONT./AL2 

ENVIRONMENTAL CONDITIONS

 Height

 Max. 2000m

80  up to 31     decreasing linearly  50  at 40    . 

%

%

 Ambient/storage temperature
 Max. Relative humidity

0 ... +50

/

   

°C -25... +70°C  (with no icing)

°C

°C

Rated pollution degree

According to EN 60529                Front panel :    IP65
                                                       Rear panel  :    IP20

 Do not use the device in locations subject to corrosive and flammable gases.

ELECTRICAL CHARACTERISTICS

 Supply

 90-250V AC, 50/60Hz or 9-30V DC/7-24V AC

 Power consumption

Max. 7VA
2.5mm² screw-terminal connections

 Wiring
 Line resistance 
 Data retention
 EMC
 Safety requirements

 EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B for standard EN 61000-4-3)   

EEPROM (minimum 10 years)

 EN 61010-1: 2001 (Pollution degree 2, overvoltage category II)

For thermocouple max.100ohm, for 3 wired PT100 max. 20ohm

CONTROL

 Control type

 Single set-point and alarm control

 On-Off / P, PI, PD, PID (selectable)

 Control algorithm
 A/D converter

 15 bits

 Sampling time
 Proportional band

 Derivative time

 Integral time

 Control period
 Hysteresis
 Output power

 500ms
 Adjustable between 0  and 100 . If Pb=0 ,  On-Off control is selected.

%

%

%

 Adjustable between 0.0 and 100.0 minutes

 Adjustable between 0.00 and 25.00 minutes
 

 and 250 seconds

Adjustable between 1

 

1 and 50

        

Adjustable between 

°C/F

  The ratio of power at a set point can be adjusted between 0  and 100

%

%

HOUSING

 Housing type

 Suitable for flush-panel mounting according to DIN 43 700.

 Dimensions  

 W96xH96xD50mm 

 Weight 

 Approx. 410g (after packing)
 Self extinguishing plastics. 

 Enclosure material 

 While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used.

 J (Fe-CuNi) Thermocouple

 K (NiCr-Ni) Thermocouple

 T (Cu-CuNi) Thermocouple
 S (Pt/0Rh-Pt) Thermocouple

 R (Pt13Rh-Pt) Thermocouple
 0-20 mA
 4-20 mA

               EN 60584
               EN 60584
               EN 60584
               EN 60584
               EN 60584
               EN 60584
               EN 60584

 0...  600
 0...1200
 0...  400
 0...1600

                  0...1600

°C

°C
°C
°C
°C

 +32... +1112

 +32... +2192
 +32...   +752
 +32... +2912

                  +32... +2912

°F
°F
°F
°F

°F

 PT100 Resistance Thermometer
 PT100 Resistance Thermometer

EN 60751
EN 60751

 -200...600 

 -99.9...300.0

 -999...4000

 -999...4000

°C
°C

 0,2% (

)

of full scale

 0,2% (

)

of full scale

1 digit
1 digit

 0,2% (

)

of full scale

1 digit

 0,2% (

)

of full scale

1 digit

 0,2% (

)

of full scale

 0,2% (

)

of full scale

 0,2% (

)

of full scale

1 digit
1 digit
1 digit

 0,2% (

)

of full scale

1 digit

 0,2% (

)

of full scale

1 digit

   -328... +1112 

  -99.9...+543.0

°F
°F

°C

°F

TECHNICAL SPECIFICATIONS

 

Input type

 Temperature range

  Accuracy

 EUC942-E-04-201312

Summary of Contents for EUC942

Page 1: ...vice in locations subject to corrosive and flammable gases ELECTRICAL CHARACTERISTICS Supply 90 250V AC 50 60Hz or 9 30V DC 7 24V AC Power consumption Max 7VA 2 5mm screw terminal connections Wiring Line resistance Data retention EMC Safety requirements EN 61326 1 1997 A1 1998 A2 2001 Performance criterion B for standard EN 61000 4 3 EEPROM minimum 10 years EN 61010 1 2001 Pollution degree 2 overv...

Page 2: ...L parameter is the value of A1 L L parameter Alarm1 value upper limit A2 H L If InP or UnIt parameters are changed the maximum value of the A2 H L parameter changes to the maximum scale value of the selected input type Minimum of A2 H L parameter is the value of A2 L L parameter NOTE If C ot S out1 this parameter is not seen Alarm2 value upper limit A1 L L If InP or UnIt parameters are changed the...

Page 3: ...one of the mA input types this parameter is seen Process value is equal or lower than 60 of the set point Yes No 25 REdY Press any key 70 TE Hi When process value decreases appropriate temperature to self tune Press any key to deactivate the self tune procedure 25 P SE t press and hold While holding key run message flashes Then when key is pressed self tune mode is entered if there is no probe fai...

Page 4: ...sequence when per press key ASET ASET SET CSET ASET NOTE The maximum of is the value of parameter and the minimum of it is the value of parameter If independent alarm is selected A1 SE and values can be adjusted between the limits of the full scale If deviation alarm is selected A1 SE and A2 SE values can be adjusted between and If band alarm is selected A1 SE and A2 SE values can be adjusted betw...

Page 5: ... grounding thermocouple do not connect the logic output terminals to the ground 1 Mains supply cords shall meet the requirements of IEC 60227 or IEC 60245 2 In accordance with the safety regulations the power supply switch shall bring the identification of the relevant instrument and it should be easily accessible by the operator Note Holding screw 0 4 0 5Nm Equipment is protected throughout by DO...

Reviews: