background image

 1/5

EC762-E-06-R

ENDA EC762 UP/DOWN COUNTER

 Thank you for choosing ENDA EC762 COUNTER.

Read this document carefully before using this device. The guarantee will be expired by 
damaging of  the device if you don't attend to the directions in the user manual. Also we don't 
accept any compensations for personal injury, material damage or capital disadvantages.  

* 72x72mm sized.
* 2x6 digits display.
* Easy to use by front panel keypad.  
* Counting up and down with a 2 channel inputs having 90° phase shift.

 

* Input frequency can be selectable.  
* Prescaler factor can be adjusted between 0.001 and 9.99999.
* Decimal point can be adjusted between 1. and 5. digits.    
* Sensor type can be selected as PNP, NPN or Encoder. 
* Single set-points control is made by a relay outputs.  
* Output can be energized continuously or just for a time interval of 0.1
   to 999.9 seconds. 
* Selectable functional reset input. 
* Input offset feature.
* Parameter access protection on 3 levels.
* Easy connection by removable screw terminal.
* CE marked according to European Norms.

ENVIRONMENTAL CONDITIONS

 Height

 Max. 2000m

 Ambient/storage temperature

 Max. relative humidity

0 ... +50

 

°C/-25 ... +70°C  (with no icing) 

Rated pollution degree

TECHNICAL SPECIFICATIONS

 

80  up to 31

decreasing linearly  50  at 40

%

%

°C 

°C

According to EN 60529                Front panel :    IP65
                                                       Rear panel  :    IP20

 Do not use the device in locations subject to corrosive and flammable gases.

 Supply

 230V AC +10% -20% or 24V AC ±10%, 50/60Hz or optional 9-30V DC / 7-24V AC ±10% SMPS module.

 Power consumption

Max. 7VA
2.5mm² screw-terminal connections

 Wiring
 Date retention 
 EMC
 Safety requirements

 EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B for the EMC standard)  

EEPROM (Min. 10 years)

 EN 61010-1: 2001 (pollution degree 2, overvoltage category II)

ELECTRICAL CHARACTERISTICS

 Count inputs (CP1, CP2)

  2 channels  (Max. 10kHz, 5V  to 30V pulse)

 PNP: Positive reset  (5V to 30V pulse with adjustable  pulse time between 2ms and 50ms)
 NPN: GND terminal is connected to the RESET IN terminal.

 Reset input

  Frequency  (Hz)

  25, 500, 1000, 2000, 5000, 7500, 10kHz (selectable by programming)

  Minimum On ans Off times
  for pulses

  20ms for f=25Hz 

  1ms for f=500Hz 

  250

m

s for  f=2kHz 

  100

m

s for f=5kHz 

  67

m

s for f=7,5kHz

  

50

m

s for f=

10

kHz

  500

m

s for f=1kHz  

 INPUTS

 OUTPUTS

 Control output (OUT)

 Relay : 250V AC, 2A (for resistive load), NO+NC
 Open collektor output (S.S. OUT): Max. 30V DC, 100mA.  

 Auxiliary power supply

 12V DC, Max. 50mA (without regulation)

 

.

Mechanical  30.000.000 operation; Electrical 300.000 operation

  Life expectancy for relays

    Note : Relay and S.S.OUT outputs are in synchronization . When OUT relay is energized S.S. OUT transistor goes into saturation.

HOUSING

 Housing type

 Suitable for flush-panel mounting according to DIN 43 700.

 Dimensions

 W72xH72xD97mm 

 Weight

 Approx. 405g (after packing)

 Enclosure material

 Self extinguishing plastics 

 While cleaning the device, solvents (thinner, benzine, acid etc.) or 

corrosive materials 

must not be used.

Order Code :

  

EC762-     

1

     Supply Voltage

     230VAC...230V AC
     24VAC.....24V AC 
     SM...........9-30V DC / 7-24V AC 

      PRESET UP/DOWN COUNTER

ENDA

SET

OUT1

EC762

PRESET

RESET

Reviews: