background image

 Blue Easy Reader Thermostat

1F95EZ-0671

Homeowner’s Guide

Summary of Contents for 1F95EZ-0671

Page 1: ...Blue Easy Reader Thermostat 1F95EZ 0671 Homeowner s Guide ...

Page 2: ...lue Easy Reader may be battery powered or system powered Either way it is recommended to keep fresh batteries installed Batteries are accessible by removing the control front from the base Whenever Change appears in the display new premium brand AA alkaline batteries should be installed If the house will be unoccupied for an extended period and is displayed install new batteries before leaving If ...

Page 3: ...0 Energy Saving Factory Pre program 12 Programming Your Thermostat 13 Copy Program 13 Heating and A C Worksheet 14 Enter Heating Program 15 Enter A C Program 15 TABLE OF CONTENTS Using Your Thermostat Programmable Mode Auxiliary Heat 16 Temporary Program Override 16 Permanent Temperature Hold 16 System Diagnostics 17 Setting Up Your Thermostat Options 18 Configuration Menu Items 18 Configuration Men...

Page 4: ...lf Capacity Change Replace Batteries Indicates Heat Pump System does not appear for multi stage or single stage Actual Room Temperature Desired Temperature Temperature Adjustment Buttons Menu Button Button Labels Solid colored labels indicate selection is On Non solid or outlined labels indicate not selected or Off Heat is on in this example Button not used Fan Button Press to select Fan operation...

Page 5: ...rn Off if it is On If your heating or A C system is a heat pump the system automatically activates Auxiliary Heating when the outside temperature is too cold for the heat pump to efficiently heat the home You can manually activate the auxiliary heating by pressing and holding the Heat button until Aux Aux changes to Aux To turn the manual auxiliary off press the Heat button again Now enjoy the simp...

Page 6: ... Air Conditioning systems and fan A C Button Press to select Air Conditioning Heat Button Press to select Heating Time of Day Day of Week 6 Blue Easy Reader Thermostat Homeowner s Guide THERMOSTAT DISPLAY OVERVIEW Button used for Programming Indicates Heat Pump System does not appear for multi stage or single stage Battery Status Full Charge Half Capacity Change Replace Batteries Fan Button Press ...

Page 7: ...1 2 3 4 5 6 7 8 9 10 11 12 BLUE EASY READER THERMOSTAT PROGRAMMABLE MODE OTHER DISPLAY ICONS FOR PROGRAMMING Blue Easy Reader Thermostat Homeowner s Guide 7 ...

Page 8: ...bility and needs a qualified technician to service the equipment 6 Shows time of day When setting the Time displays time or date Each press of the Time button will change hour minute Year Month and Date In Sched Schedule mode will show start time for period 7 In Normal operation the current day of the week will be displayed When setting the Time indicates the day of the week selected In Sched mode ...

Page 9: ...e desired temperature is adjusted with the or keys to the temperature limit selected in the setup menu 11 Hold Copy Menu Menu indicates button to press to access the programming and time setting functions or to enter the Configuration menu Hold indicates button to press to enter permanent Hold Copy is used in programming 12 Sched Indicates button to press to enter Sched mode to enable setting of pr...

Page 10: ...A C press Menu button to display additional button choices SETUP GUIDE FOR PROGRAMMABLE OPERATING MODE 1 3 2 10 Blue Easy Reader Thermostat Homeowner s Guide To change your thermostat to be a Programmable Item 14 Schedules per Week in Configuration Menu must be changed from P0 to P7 See page 18 19 Setting Up Your Thermostat Options ...

Page 11: ...orrect hour and A AM or P PM 4 Press Time to display the minutes 5 Repeat steps 3 and 4 to set minute s Year Month and day of week 6 Press Run to return to home screen and run the preset program that meets Energy Star guidelines Blue Easy Reader Thermostat Homeowner s Guide 11 4 6 ...

Page 12: ...o Bed Night Heating Program 6 00 AM 70 F 8 00 AM 62 F 5 00 PM 70 F 10 00 PM 62 F A C Program 6 00 AM 75 F 8 00 AM 83 F 5 00 PM 75 F 10 00 PM 78 F SETUP GUIDE FOR PROGRAMMABLE OPERATING MODE This thermostat is set up for 7 independent day programming with 2 or 4 time temperature periods per day If the factory programming meets your needs skip to page 16 using your thermostat If you wish to change t...

Page 13: ...ating lower temperatures will save energy ÊIn A C higher temperatures will save energy COPY PROGRAM When programming your thermostat you may copy the program from one day to another day To copy a program 1 In Sched mode enter the program for the day 2 Press Copy Copy will begin to flash and the day being copied will show 3 Press Advance Day to select the day to copy to This day will be flashing 4 Pr...

Page 14: ...78 F Worksheet for Re Programming 7 Day Program Heating Program Wake Up Morning Leave For Work Day Return Home Evening Go To Bed Night MON 6 00 AM 70 F 8 00 AM 62 F 5 00 PM 70 F 10 00 PM 62 F TUE WED THU FRI SAT 6 00 AM 70 F 8 00 AM 62 F 5 00 PM 70 F 10 00 PM 62 F SUN 6 00 AM 70 F 8 00 AM 62 F 5 00 PM 70 F 10 00 PM 62 F Fill in the blank worksheet with your desired times and temperatures PROGRAMMI...

Page 15: ...and temperatures match your desired heating schedule press Run The thermostat will now run your heating program ENTER A C PROGRAM Press A C to place thermostat in air conditioning mode Set the A C program following the Enter Heating Program steps ENTER HEATING PROGRAM 1 In Heat mode press the Menu button to display additional button choices 2 Press Sched button The display will show the day being ...

Page 16: ...to the left of the desired temperature Press the Hold button to maintain the new temperature 1 Press Heat or A C button to turn your system On Press Off to turn Heating and A C Off Fan will turn Off if it is On 2 Press Run or Run Sched to begin running thermostat program 3 Press either the or buttons to change the desired room temperature setting 4 Press the Fan button to select the desired fan op...

Page 17: ... press Run Sched or you manually adjust to another temperature SYSTEM DIAGNOSTICS Call for Service will be displayed if your heating or air conditioning system has diagnostic capability and needs a qualified service technician to service the equipment On some systems with diagnostic capabil ity Call for Service will flash on thermostat display when a technician is needed USING YOUR THERMOSTAT PROGRA...

Page 18: ...nly 5 Heat Pump Configuration Cycle Rate Cr Heat A C ME SL FA Heat Pump HP1 HP2 only A C Cycle Rate Cr A C ME SL FA SS1 MS2 only Auxiliary Heat Cycle Cr AUX Heat FA SL HP1 HP2 only 8 Compressor Lock out CL OFF On Installer Set 9 System Mode Configuration Heat A C Off Heat Off Fan Heat Off A C Off Installer Set SETTING UP YOUR THERMOSTAT OPTIONS To enter the Configuration Menu Easy Reader ther mostat ...

Page 19: ...S 2 4 16 Fast HEAT HEAT FA On Off 17 Fast A C A C FA On Off 18 Daylight Savings Time dS On Off 19 Temperature Range Heat Limit HL 99 62 98 20 Temperature Range A C Limit LL 45 46 82 21 Dual Fuel Electrical Fuel dF 0 1 9 HP1 HP2 Installer Set 22 Compressor Delay Cd 60 00 99 HP1 HP2 Installer Set 23 O B Output Configuration On A C O On Heat B Installer Set 24 Exit Menu SETTING UP YOUR THERMOSTAT OPTI...

Page 20: ...am period Heat Cycle Rate Setting if system is MS or SS Default setting is ME medium if you desire a longer heating cycle set to SL Slow or shorter cycle set to FA Fast Heat Pump Cycle Rate Setting if system is Heat Pump Default setting is ME medium if you desire a longer heat pump cycle set to SL Slow or shorter cycle set to FA Fast A C Cycle Rate Setting or Aux Heat Cycle Rate Default setting is...

Page 21: ...Record the setting Display light The display light is defaulted on so when any button is pressed the light will illuminate the display When set to Off the light will not turn on Temperature Display Adjustment The Easy Reader thermostat was accurately set at the factory However if you want to change the temperature you can adjust the reading by plus or minus five degrees Your thermostat displays to ...

Page 22: ... Day Evening Night per day Fast Heat If your system is a multi stage and or Heat Pump you can select to have the additional stage of heating come on anytime the temperature setting is adjusted up by three degrees or more If you do not desire this feature select Off Fast A C If your system is a multi stage Air Conditioner or multi stage Heat Pump you can select to have the additional stage of A C c...

Page 23: ...t The Easy Reader thermostat can be set to limit the lowest desired temperature in A C to anywhere between 46 and 82 Dual Fuel Setting Set by installer to match your heat pump dual fuel system Record the setting Compressor Delay for Dual Fuel Set by installer to match your heat pump dual fuel system Record the setting O B Output Configuration Set by installer to match your heat pump system Record t...

Page 24: ...C ME SL FA Auxiliary Cycle Rate Cr Heat FA SL Compressor Lockout CL Off On Mode Configuration Heat A C Off Heat Off Fan Heat Off A C Off Compressor Optimization CO Off On Display Light dL On Off Temperature Display Adjust 0 Hi __ 1 to 5 Hi __ 1 to 6 Lo F C Selection F C Schedules per Week P 0 7 Periods per Schedule Day PS 2 4 Fast Heat Heat FA On Off Fast A C A C FA On Off Temperature Range Heat Li...

Reviews: