LogicMachine Re:actor Lite  

Re:actor Lite 

 is your easiest way to 

program complex logic in KNXnet/IP, 
Modbus TCP, BACnet IP networks.  
Re:actor Lite will enable you  efficiently 
customize building automation 
processes, easily delivering unlimited 
flexibility benefit to end users in a cost-
effective way. 

Re:actor Lite 

 is an embedded 

platform with integrated Ethernet,  
Serial interface, 34 I/O ports.  

 
 

ENG - Data sheet 

Issue date 12.06.2015 
 
 

 

 
 

 

Application 

 
Logical functions; I/O device; WEB SCADA visualization for PC and touch-devices; cross-
standard IP gateway; integration with third party devices over RS485 serial port 

– AV, IR, 

HVAC; Data logger with trends; Thermostat etc.  
 
 
 

Summary of Contents for LogicMachine Reactor Lite

Page 1: ...u efficiently customize building automation processes easily delivering unlimited flexibility benefit to end users in a cost effective way Re actor Lite is an embedded platform with integrated Ethernet Serial interface 34 I O ports ENG Data sheet Issue date 12 06 2015 Application Logical functions I O device WEB SCADA visualization for PC and touch devices cross standard IP gateway integration wit...

Page 2: ...DC Power over Ethernet recommended supported Power consummation 1 5W Interface 10BaseT 100BaseTX 1 RS485 1 1 Wire 1 Binary inputs 18 Digital outputs 16 380 mA continues current on output Connections Power supply 1 5mm2 Serial 1 5mm2 IO 1 5mm2 Operating elements LED 1 CPU load 1 Activity Enclosure Material Polyamide Color Gray Dimensions 104 W x90 H x32 L mm Usage temperature 5C 45C Storage tempera...

Page 3: ...health or life or with application that can result danger of people animals or real value Mounting advice The devices are supplied in operational status The cables connections included can be clamped to the housing if required Electrical connection The devices are constructed for the operation of protective low voltage SELV Grounding of device is not needed When switching the power supply on or of...

Page 4: ...u can either reboot the device by pressing RESET button or reset the configuration to factory defaults Press and hold for 10 sec reboot the device Press and hold for 10 sec reset networking with IP to factory default Press and hold for 10 sec and again press and hold for 10 sec full reset of configuration to factory defaults ...

Page 5: ...5 Connection diagrams Powering through PoE Digital input ...

Page 6: ...6 Digital output e g external relay ...

Page 7: ...7 1 Wire ...