Instruction Manual

ModelSV2100/SV2100-I

070098-S-010 Rev N         

ENG

http://waterheatertimer.org/COPD-exercises.html

http://waterheatertimer.org/COPD-exercises.html

Summary of Contents for SmartVest SV2100

Page 1: ...ade in USA Accredited by The Joint Commission MDSS GmbH Schiffgraben 41 30175 Hannover Germany ISO 13485 ISO 9001 Certified Instruction Manual Model SV2100 SV2100 I 070098 S 010 Rev N ENG http waterheatertimer org COPD exercises html http waterheatertimer org COPD exercises html ...

Page 2: ......

Page 3: ...Service Representative 888 966 2525 Instruction Manual Model SV2100 SV2100 I 070098 S 010 Rev N ENG 2013 Electromed Inc ...

Page 4: ......

Page 5: ...ectromed Inc welcomes feedback on methods for improving the quality of our products and service Whether this feedback is regarding information presented in this Manual the operation of the System itself or any other matter we truly appreciate your input If you would like to provide feedback do not hesitate to contact us using one of the methods shown below We thank you in advance for your assistan...

Page 6: ... 8 Using a Vest Extender 8 Using a Foam Pad 8 Cleaning the Long Term Use LTU SmartVest 8 Removing the Inner Bladder 8 Reinserting the Inner Bladder 9 Cleaning the Long Term Use LTU SmartVest Wrap 9 Connecting Hose 10 SV2100 SV2100 I Air Pulse Generator 11 Power Cord 11 Control Panel Overview 12 Setting Treatment Protocols 13 Setting Manual Mode 13 Setting Program Mode 14 Starting the Treatment Pro...

Page 7: ... and Accessory Bag 18 Institutional Products 19 Single Patient Use SPU SmartVest 19 Single Patient Use SPU SmartVest Wrap 19 SV2100 I and Mobile Pedestal 19 Single Patient Use SPU Connecting Hose 19 Troubleshooting 20 Specifications 22 Electromagnetic Compatibility 23 Prescription Record 26 ...

Page 8: ......

Page 9: ...ed by a programmable air pulse generator The rapid squeeze and release action of an HFCWO treatment simulates repetitive mini coughs which have been reported to effectively Shear mucus away from the walls of a lung s airways 1 Reduce the viscosity of the secretions 2 Propel the mucus toward the larger airways where it can be expectorated or suctioned more easily 1 2 1 Chang HK Weber ME King M Mucu...

Page 10: ...nce System with an extension cord Do NOT use the SmartVest Airway Clearance System near water near any wet surface or in highly humid environment If the system becomes wet allow it to dry completely before plugging it in again Cord and hose may pose a strangulation or entanglement hazard Do NOT route components near neck or leave at risk individuals unattended Items applied to the SmartVest Airway...

Page 11: ...ue or hot irons to the SmartVest shell while inner bladder is installed Do NOT allow any foreign materials to enter the SmartVest Airway Clearance System through openings in the device hose or garment Moving air in the SmartVest garment along with multiple layers of clothing may cause you to become warm during use Use system in a cooled or ventilated room and wear a single layer of clothing undern...

Page 12: ...e SmartVest Airway Clearance System is IPXO classified ordinary equipment against the ingress of water The equipment is NOT suitable for use in the presence of flammable anesthetic mixture with air or with oxygen or with nitrous oxide This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this d...

Page 13: ...om of an underlining infection disease or more serious condition Therefore the American Association for Respiratory Care AARC Guidelines for Postural Drainage Therapy advises that the decision to use this device for Airway Clearance Therapy requires careful consideration and clinical assessment for each patient For further information regarding indications contraindications etc refer to AARC Clini...

Page 14: ...ication is intended for patients finding it difficult to fit or apply the standard SmartVest The SmartVest Wrap is reversible allowing the hose to connect to either the right or left side Wearing the SmartVest or SmartVest Wrap For a proper fit make sure you wear a single layer of clothing underneath the SmartVest or the SmartVest Wrap Fitting the SmartVest Steps 1 Put on the SmartVest without sec...

Page 15: ...est 4 Layer the printed side of the SmartVest Wrap over the unprinted side using the Velcro type closure NOTE The garment should fit snugly but not tightly 5 Attach the hose to the SmartVest Wrap refer to the section on Connecting Hose Correct Fit Incorrect Fit Steps 1 2 Step 3 Steps 4 5 NOTE If the front closure opens during treatment it can be secured by opening the small strap on the left side ...

Page 16: ...move the inner bladder before attempting any vest cleaning methods The inner bladder may be wiped off with a damp cloth Do not machine wash or dry clean the inner bladder The outer shell may be wiped off with a damp cloth machine washed or dry cleaned Once the bladder is removed fully secure all Velcro type closures Wash the shell by itself in a washing machine Use the gentle cycle with cool water...

Page 17: ...lide the bladder up into the outer shell 5 Tuck the four shoulder straps of the bladder into the Velcro type attachment points working the ends into the corresponding pockets 6 Attach the fifth strip near the air hose connector 7 Check the bladder position and readjust the Velcro type attachments where necessary 8 Close the zipper Cleaning the Long Term Use LTU SmartVest Wrap Use the following car...

Page 18: ...me on both ends Therefore whether connecting to the generator or the SmartVest garment the insertion steps are the same Steps 1 With one hand supporting either the generator or the SmartVest garment connection point use the other hand to insert the hose connector 2 Give a slight twist NOTE It is not necessary for all three o rings on the connector to be fully inserted for a proper seal Correct Con...

Page 19: ...zontal position Anytime the generator is stopped or paused and the orientation of the device changes the display will automatically appear in the proper position Power Cord A grounded 3 prong power cord is supplied with the device and must be connected to a properly grounded electrical outlet Once the power cord is connected to the generator and outlet the generator will automatically power up Thi...

Page 20: ...s button to start stop or resume a treatment protocol Set Press this button to store the displayed values Return to Home Press this button to return to the main screen Power Indicator Light This light will be visible when the generator is plugged in and receiving power Air Pressure Control Dial Adjust this dial to set the amount of hug felt from the SmartVest during treatment In addition there are...

Page 21: ...riptions or one user to set three different treatment protocols Setting Manual Mode Steps 1 From the Home screen press next to the word MANUAL 2 Set the following items Set the Time by pressing and buttons to the left of the screen NOTE The time setting can only be changed when unit is not pulsing Set the Frequency by pressing and buttons to the right of the screen NOTE Frequency settings can be c...

Page 22: ...e Home screen press either or next to PROGRAM 1 PROGRAM 2 or PROGRAM 3 2 From the selected PROGRAM mode screen press to select the first interval of the treatment protocol 3 With line A highlighted use or to the left of the display screen to set the required Time NOTE Time is adjustable in 30 second increments up to 30 minutes ...

Page 23: ...y is adjustable in 1 Hz increments from 5 to 20 Hz 5 Press to save the setting and advance to the next line 6 Repeat this process for lines B F or for as many intervals as are required up to a maximum of 6 by your prescribed treatment protocol NOTE Any line left as 0 00 will be skipped during treatment This same procedure can now be repeated to set additional PROGRAM modes PROGRAM 1 PROGRAM 2 or P...

Page 24: ...1 3 until all intervals of prescribed treatment are complete 5 Press at any time to return to the Home screen Using Sleep Mode In order to conserve energy the SmartVest Airway Clearance System will automatically enter sleep mode after 15 minutes of inactivity While in sleep mode the display and fan will be off but the power indicator light will remain lit To manually place the system into sleep mo...

Page 25: ...ools are required to perform this task If you need additional filters contact your Service Representative Steps 1 Remove the filter access door on the bottom of the generator To do this a Press the release tab b Pull up on the access door 2 Remove and discard the old filter NOTE The old filter may not look much different than the new filter Therefore it is important to discard the filter immediate...

Page 26: ...or your SmartVest hose power cord filter and fuse kits and training materials The back of the accessory bag has a convenient slot where the handle of the carrier fits through This feature allows the accessory bag to sit snugly on top of the generator bag and against the telescoping handle as you wheel the carrier resulting in a single wheeled component CAUTION The wheeled carrier is designed to ca...

Page 27: ...onger needed whichever comes first SV2100 I and Mobile Pedestal The SmartVest Model SV2100 I Air Pulse Generator is available for institutions requiring easy mobility of the SmartVest Airway Clearance System This model is specifically designed to mount to a Mobile Pedestal which features Rugged attachment of the air pulse generator Stable 5 caster base with 2 locking casters Foot operated lever fo...

Page 28: ...cation move it to a acceptable limit The cooler location and unit will NOT start in try again later this state as damage may occur If this does not resolve the issue contact your Service Representative Error 2 The motor temperature Leave the unit plugged in is below 50 degrees and turned on so the fan can Fahrenheit 10 degrees assist in warming up the Celsius and needs unit With the unit power on ...

Page 29: ...ose is free of leaks SmartVest inner bladder is free of tears The inner bladder of the SmartVest is attached smoothly inside the outer shell The Velcro type closures are lying flat and are free from buckling Replace the air input filter refer to the section on Replacing a Filter The garment will slightly compress the chest during treatment Reduce pressure with the Pressure dial until you are comfo...

Page 30: ... sizes for long term and single patient use 100 240 V 50 60 Hz 3 3 Amps at 100 V 1 6 Amps at 240 V Fuses Two 2 5mm x 20mm 5 Amp 250VAC Fast Acting 1500 Amp Breaking Capacity 50ºF 84ºF 10 C 29 C 15 93 relative humidity non condensing 70 kPa to 106 kPa 4 F 140 F 20 C 60 C 5 95 relative humidity non condensing 50 kPa to 106 kPa Operational Parameters Air Pulse Generator Vest s Wrap s Electrical Opera...

Page 31: ... 95 dip in UT for 5 s 3 A m Compliance level 6 kV contact 8 kV air 2 kV for power supply lines N A for input output lines 1 kV line s to line s 2 kV line s to earth 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 s 3 A m Electromagnetic environment guidance Floors should be wood concrete or ceramic tile If floors are covered ...

Page 32: ...ration distance in metres m Field strengths from fixed RF transmitters as determined by an electromagnetic site surveya should be less than the compliance level in each frequency rangeb Interference may occur in the vicinity of equipment marked with the following symbol NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electroma...

Page 33: ...t power of the communications equipment 0 01 0 12 0 12 0 23 0 1 0 37 0 37 0 74 1 1 17 1 17 2 33 10 3 70 3 70 7 37 100 11 70 11 70 23 30 For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in ...

Page 34: ...utes treatment ______pressure setting ______pressure setting ______pressure setting Frequency Duration Frequency Duration Frequency Duration _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________...

Page 35: ...ue NW New Prague MN 56071 www Electromed com Made in USA Accredited by The Joint Commission MDSS GmbH Schiffgraben 41 30175 Hannover Germany ISO 13485 ISO 9001 Certified Instruction Manual Model SV2100 SV2100 I 070098 S 010 Rev N ENG ...