background image

UPS

Uninterruptible Power Supply

MT 3200

Instruction Manual

Item number:

022 / 03200MT-000

Januar 2010

Summary of Contents for MT 3200

Page 1: ...UPS Uninterruptible Power Supply MT 3200 Instruction Manual Item number 022 03200MT 000 Januar 2010...

Page 2: ...6 1 2 Display elements of the UPS 13 6 2 Equipment elements on the rear panel 14 6 3 Audible alarm signals of the UPS 16 7 Storage and unpacking 17 7 1 Storing the UPS 17 7 2 Unpacking the equipment...

Page 3: ...pport time 30 13 2 Replacing the batteries 31 13 3 Service log 32 13 4 Service hotline 33 13 5 Maintenance and service contracts 33 14 Technical Data 34 14 1 Equipment specifications 34 14 2 Accessori...

Page 4: ...mation and tips Recycling symbol Denotes components that are governed by the electronic scrap ordinance Denotes components or parts that must be disposed of in a specific manner Never throw these comp...

Page 5: ...ers misuse vandalism inappropriate use maintenance errors or incorrect repairs by third parties o Modifications unauthorised tampering incorrect operation another device or accessory incorrect install...

Page 6: ...sses or damage made by third parties against you o Loss of or damage to your records or data or the cost of their recovery o Financial consequential damage including loss of earnings or savings or inc...

Page 7: ...3 2 Transportation and storage The UPS may only be transported to its place of intended use in the original packaging The same applies for removals or returns The equipment must not be transported or...

Page 8: ...a fixed connection to the consumer load a suitable cable must be used The fuse protection for the consumer load must always be installed directly in front of it and never centrally in front of the UP...

Page 9: ...Defective batteries must be disposed of in an environmentally friendly manner Never throw batteries into the regular refuse The local waste disposal regulations must be observed 3 7 Maintenance servic...

Page 10: ...ors in this description or their consequences The purpose of UPS equipment Uninterruptible Power Supply is to protect sensitive electrical devices such as computers workstations electronic points of s...

Page 11: ...pack Fig 1 Block diagram MT series The block circuit diagram shows the individual modules of the equipment and provides a general impression of how they interact If the mains power failure exceeds the...

Page 12: ...with instructions on its operation as well as all information on equipment connections 6 1 Display and operator control elements on the front panel Fig 2 Front view MT3200 All of the operator control...

Page 13: ...disabled The display flashes if mains voltage is present but the equipment is switched off Battery mode Support mode is active The input mains power is not available or is outside the tolerances The...

Page 14: ...plug connections on the rear panel with the exception of the communication interface are on the mains power potential when connected Even when disconnected dangerously high voltages may be present at...

Page 15: ...label or in the technical data of this manual e Communication 9 pin D Sub jack Via the serial interface RS232 all of the relevant UPS data are transmitted to an appropriate primary control unit e g P...

Page 16: ...ation sounds in the following sequence A beep beep long pause 8 s beep beep repeating Support mode and low battery capacity The audible warning notification sounds in the following sequence B beep bee...

Page 17: ...optional must be operated for a period of approx 8 hours to prevent deep discharging of the batteries 7 2 Unpacking the equipment Remove the shipping cartons and packaging material Always store the e...

Page 18: ...uring installation The load bearing capacity of the support must be sufficient o Observe the specified installation location and only mount the equipment using the screw in positions shown o Make sure...

Page 19: ...cause material damage The protective earth conductor must always be connected If not the consumer loads will also not be earthed Warning The connection diagram shown in Fig 6 only applies if o the loo...

Page 20: ...RS232 GND 9 RS232 Transmit data Tx The communications interface is completely galvanically isolated The LAN signals have a shared earth which is not connected to the RS232 earth The UPS can also be fo...

Page 21: ...t yet been switched on Display alarm signal the ON Line indicator flashes Startup mode If the mains power is available the startup procedure is initiated when the main switch on the front of the equip...

Page 22: ...as well as the current value of the output load here 50 No audible alarm signal A V R mode Within certain limits A V R mode compensates for over or under voltage in the power supply without drawing cu...

Page 23: ...PS switches off after a short time interval approx 20 seconds The UPS switches off immediately in the event of a short circuit on the output side Display alarm signal overload mode is indicated by ill...

Page 24: ...the equipment the UPS immediately switches to fault mode This switches off the load at the output This operating mode can then only be reset by powering down the UPS completely Display alarm signal in...

Page 25: ...onomously Only the switching on and switching off is performed by the operator In addition data can be exchanged via the communications interface but this is not absolutely necessary for the general o...

Page 26: ...approximately 10 seconds This operating mode is only used to test the function of the UPS In this mode the battery capacity indicator only provides a rough indication of the battery pack charge statu...

Page 27: ...e UPS will be in on line mode and the load indicator will be less than 100 5 Now switch the system off main switch on the front of the equipment 6 Wait a few seconds refresh 7 Switch the UPS on again...

Page 28: ...ging time is less than the rated value The batteries are not fully charged or individual batteries are defective Charge the batteries for more than 8 hours and repeat the test If the problem persists...

Page 29: ...Internet home page http www effekta com The following basic functions are supported by all software packages o Detection and display of the UPS mains power status o Display of the UPS output status o...

Page 30: ...pport time Before starting this procedure it is absolutely essential to save all open data Also inform all employees concerned There are essentially two methods of measuring the support time Method a...

Page 31: ...ins power supply Work on the battery pack may only be carried out by technical personnel who have received specific training in the handling of batteries Note that high voltages remain in the equipmen...

Page 32: ...USV MT3200 Instruction manual MT Series Page 32 of 36 13 3 Service log Enter all maintenance and servicing work performed on the UPS equipment into the service log Date Work carried out Carried out by...

Page 33: ...com html kontakt html 13 5 Maintenance and service contracts EFFEKTA Regeltechnik GmbH offers you tailored maintenance and customer services that ensure the highest possible reliability and availabili...

Page 34: ...voltage support mode 230 V AC sine 6 Max output current 13 9 A Overload capacity 110 130 10 25 s 130 1 5 s Bridging time approx 8 min under rated conditions Efficiency AC AC 95 DC input Input voltage...

Page 35: ...down and diagnosis software LAN PowerShut LAN RS232 connection Interface connection cable M2502 14 3 List of wearing parts The following components are subject to normal wear and tear and are therefor...

Page 36: ...ces operating within a restricted voltage range 93 EEC supplement to guideline 73 23 EEC 89 336 EEC guideline on electromagnetic compatibility 92 31 EEC supplement to EMC guideline 89 336 EEC Standard...

Reviews: