USER MANUAL

P/N 19655-D 

Rev. 11/30/16

Summary of Contents for Perk

Page 1: ...USER MANUAL P N 19655 D Rev 11 30 16...

Page 2: ...n conjunction with original Edge Systems products Use of Edge Systems together with non original Edge Systems products including but not limited to treatment media serums and solutions is a breach of...

Page 3: ...Waste Canister Tubing 11 OPERATING INSTRUCTIONS Turn on the System Standby Sleep Mode Touchscreen Operation Skin Solution Vials 13 SYSTEM CLEANING PREVENTIVE MAINTENANCE After Each Service 14 TROUBLES...

Page 4: ...by Edge Systems LLC This beauty device is intended to be used by trained skincare professionals at a commercial establishment such as salon spa beauty store or other aesthetic practices It is not inte...

Page 5: ...nstructions Bedienungsanleitung Mode d emploi OFF Power AUS Stromversorgung ETEINT Alimentation ON Power EIN Stromversorgung ALLUME Alimentation STANDBY Power STANDBY Stromversorgung PAUSE Alimentatio...

Page 6: ...n that could possibly cause bodily injury or death Ruft Aufmerksamkeit zu einem Verfahren Praxis oder Bedingung die vielleicht k rperliche Verletzung oder Tod verursachenk nnte Une attention particuli...

Page 7: ...e procedure and covered with protective eyewear or damp cotton pads Sterile eye rinse solution should be available at all times to rinse the eyes Removing contact lenses prior to procedure is recommen...

Page 8: ...eil qui est retourn Edge Systems LLC avec des modifications non s curitaires sera ramen son tat de fonctionnement initial aux frais du client WARNING Equipment not suitable for use in the presence of...

Page 9: ...verschiedene Steckdose zu damit die Ausr stungen und der Empf nger auf verschiedenen Zwei genkreisl ufen sind Cet appareil a t con u conform ment aux limites de l organisme de r glementation en mati...

Page 10: ...ne doit tre fait avec un chiff on propre sec ou l g rement humide Tout c ble et toute pi ce de rechange doivent tre achet s directement aupr s d Edge Systems LLC CAUTION All electronic repairs and com...

Page 11: ...Systems at 800 603 4996 or 562 597 0102 and we will assist you in the repair or replacement of your equipment Do not return your unit without first contacting Edge Systems and receiving an RMA Return...

Page 12: ...tened to the unit NOTE If the waste container is not installed or installed incorrectly a CAUTION warning will be displayed on the screen and the waste container caution light located in the upper rig...

Page 13: ...he switch to the icon to turn on the unit 3 If the power cord is plugged into the bottom power entry port press the switch to the icon to turn on the unit STANDBY SLEEP MODE 1 Press the illuminated St...

Page 14: ...le use only Discard after use 3 Go to the Main Screen and select Perk Adjust the vacuum setting as needed There are five 5 vacuum settings with setting 1 as the lowest strength and setting 5 as the hi...

Page 15: ...use Edge Systems Cleaning Solution It is specifically developed to flush through the tubing line to remove and prevent any product or impurity build up 3 Go to the Main Menu by pressing the Home butto...

Page 16: ...ds inside your touchscreen Do not wipe the screen with a cloth or sponge that could scratch the surface WEAR AND TEAR ITEMS The following items are subject to wear and tear through normal to high volu...

Page 17: ...e tubing and corresponding attachments are properly connected Vial Tip is improperly installed Make sure that vial tip is firmly installed onto the Skin Solution Vial Waste Container is full Do not le...

Page 18: ...or labor except as specifically stated below WHAT IS NOT COVERED THIS WARRANTY DOES NOT COVER ANY EQUIPMENT WHICH HAS BEEN DAMAGED BY ACCIDENT MISUSE ABUSE MODIFICATION WHICH HAS BEEN USED IN VIOLATI...

Page 19: ...ct Edge Systems within the warranty period Edge Systems can be reached by telephone toll free at 1 800 603 4996 The Customer is responsible for all arrangements and shipping charges incoming and outgo...

Page 20: ...arin Coumadin Warfarin Daily Aspirin NSAID or Vitamin E etc Breast feeding pregnancy Cancer or post cancer treatments Cardiovascular problems Cold sores or fever blisters without pre medication Cortis...

Page 21: ...tage III or IV acne Skin lightening or bleaching agent Sunburn Swollen or infected tonsils Thyroid conditions Type I diabetic Under medical care for an existing or suspected condition or disease Viral...

Page 22: ...eatment is strictly an elective cosmetic procedure and that no medical claims have been expressed or implied _____ initial here 9 I acknowledge that I should avoid use of aggressive exfoliation waxing...

Page 23: ...21 Appendix I Client Questionnaire Consent Form P E R K User Manual This page is intentionally left blank...

Page 24: ...EDGE SYSTEMS LLC 2277 Redondo Avenue Signal Hill CA 90755 USA Tel 800 603 4996 562 597 0102 Fax 562 597 0148...