background image

 

Range 1 

– AMS100 

Operating instructions

 

 

ECOSAFE | Date du document : 29/04/2019 – Version : 01 

 

 
 
 

Instruction manual 

For safety cabinet

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Model AMS100 

Summary of Contents for AMS100

Page 1: ...Range 1 AMS100 Operating instructions ECOSAFE Date du document 29 04 2019 Version 01 0 Instruction manual For safety cabinet Model AMS100 ...

Page 2: ...CONTENT 1 Description Use Page 2 2 Technical features Page 2 3 Installation and commissioning Page 2 4 Internal equipments Page 3 5 Storage Page 3 6 Ventilation Page 3 7 Safety controls Page 4 8 Spare parts Page 5 9 Recycling Page 5 10 Warranty Page 6 11 Control sheet for the user Page 7 ...

Page 3: ...ram for flammables provided Two swing doors Self closing doors Locking system CO2 extinguisher provided 500g automatic triggering by thermal bulb between 65 and 72 C Sloping roof High retention capacity External dimensions H 1500 x W 800 x D 400 mm Internal dimensions H 1250 x W 780 x D 370 mm Storage capacity 100 liters Retention capacity 112 liters Loading capacity 50 KG Weight 70 KG 3 INSTALLAT...

Page 4: ... The cabinet is provided with 3 perforated shelves These must be fixed at the chosen height thanks to the rack and pinion Take care not to exceed the loading capacity per shelf of 50 KG The cabinet also has an integrated retention tank provided with a drain plug positioned under the cabinet It should not be used as a storage area Its retention capacity is 112 liters 5 STORAGE Your safety cabinet i...

Page 5: ...n a healthy fashion Filtration boxes are delivered with the activated carbon filter that you need to renew once a year Running without any mechanic ventilation It is possible for your safety cabinet to run without mechanical ventilation However your cabinet has to be placed in a location that provides its own ventilation system at least 5 times the volume of the location per hour The cabinet itsel...

Page 6: ... again every 5 years or less in the presence of a DRIRE expert who will stamp his validation after the test We recommend you to check the CO cartridge every year to insure they do not present any traces of oxydation which could lead to their deterioration and that the CO charges are wihtin the indicated limits These verifications must be conducted by your maintenance service If you encouter any pr...

Page 7: ...house The spare parts are under 3 months warranty upon their settlement The warranty cannot be applied in the following cases The equipment has not been stored used or maintained in accordance with the standards by the user In case of a damage of the equipment by the user or a third party The equipment had a modification or a repair by the user or a third party without any prior written authorizat...

Page 8: ...he closing of the doors are working correctly The locking system of the doors works correctly The CO2 extinguisher has been controlled The standardized pictogram on the door is in good condition and visible The door hinges are lubricated The locking system is lubricated The shelves and the containment sump are clean Remarks Date By Signature ...

Reviews: