background image

GRID CONNECT SOLAR USER MANUAL 

 
 
 
 

 
 

              

 

         

Phone: 0499003158 

            

 

 

 

            Or  0450696606 

           

 

 

 

            Email: [email protected] 

           

 

 

 

 

           Web: www.ecotechelectrical.com.au

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for GRID CONNECT SOLAR

Page 1: ...GRID CONNECT SOLAR USER MANUAL Phone 0499003158 Or 0450696606 Email info ecotechelectrical com au Web www ecotechelectrical com au...

Page 2: ...commercial class 2 installs 4 3 System savings 5 4 System maintenance 5 4 1 Maintenance schedule 6 5 System operation procedures and alarms 7 5 1 Start up procedure 7 5 2 Shutdown procedure 7 5 3 Syst...

Page 3: ...ve explained to you the location s of the array s where the inverter or envoy is to be located any variations in the job and a rough time frame of the install Your electricity meter will most likely h...

Page 4: ...new bi directional meter in which you will sell back to your retailer at the same price you bought it for eg If you pay 25c per kilowatt hour you will receive a credit of 25c per kilowatt hour sent ba...

Page 5: ...ed anti islanding which stops it from working once there grid voltage or frequency is out of order this helps prevent any faults or spikes arising which could damage the inverter or sensitive equipmen...

Page 6: ...sues and various other factors that affect the output of a solar system 4 SYSTEM MAINTENANCE Maintaining a solar system is integral to the output as dust and bird droppings accumulate on the panels de...

Page 7: ...ches r circuitbreakersandfuses if applicable r Recordstringvocandiscvalues r checkintegrityof surge diverters r checkforcorrectlabeling r WiringSystems Enclosures Verifyintegrityof cablingandenclosure...

Page 8: ...g the inverter off To turn the inverter off is the opposite to turning it on this will be on rare occasions but is good to know in emergency situations 1 Turn off the AC isolator located next to the i...

Page 9: ...tors If your system is producing close to zero kWh per day try turning the inverter on and off again as mentioned above if this fails to rectify the problem please contact Eco Tech Electrical 5 4 Eart...

Page 10: ...o Tech Electrical Note keep in mind if there is some type of grid failure the inverter will not turn on at all until the grid has been re energised 6 INSTALLATION AND MANUFACTURERS WARRANTIES AND OTHE...

Page 11: ...closed purpose With a right to undisturbed possession That match the sample or demonstration model provided More information can be found at the ACL website http consumerlaw gov au business and the ac...

Reviews: