RM85 

INDUSTRIAL DEHUMIDIFIER 

OWNER’S MANUAL 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 

www.eipl.co.uk  

Summary of Contents for RM85 10560RG-GB

Page 1: ...Page 1 of 8 Drawing TPC406 Issue 3 Date 08 08 14 RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www eipl co uk...

Page 2: ...air is therefore discharged from the dehumidifier at a slightly higher temperature with a lower absolute humidity than that which entered Continuous circulation of air through the dehumidifier gradua...

Page 3: ...l GWP of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this unit please refer to the pr...

Page 4: ...i If the air temperature is above 25 C frost and or droplets of condensed water should cover the entire evaporator coil F When the unit is operated in ambient of less than 15 C a defrost cycle should...

Page 5: ...roplets of water rather than frost Partial frosting accompanied by frosting of the thin capillary tubes indicates loss of refrigerant gas or low charge 4 Check all wiring connections including mains c...

Page 6: ...he refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak causing...

Page 7: ...fault 3 Loss of refrigerant gas 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center Little or no defrost when required 1 Faulty timer 2 Faulty by pass va...

Page 8: ...ch 3036779 1 17 Fan 3040278 1 18 Fan inlet ring 3040283 1 19 Wheel 3050124 2 20 Rubber foot 3101436 2 21 Condensate pump 3160151 1 22 Compressor 3944933 1 UK Head Office Ebac Industrial Products Ltd S...