background image

EMPX operators 

Installation & maintenance information

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

IF 1857

TECHNICAL DATA

This product is not intended to be used alone.  The electrical apparatus or systems to which 

it is being incorporated require certification as a whole when intended for use in explosive 

atmospheres.  The 3/4” NPSM thread joint of this product, and the thread of the equipment 

to which it is being incorporated, must have a female 3/4” NPSM thread attending the 

requirements for threaded joints.

ELECTRICAL SPECIFICATIONS

PUSHBUTTONS:

ILLUMINATED PUSHBUTTONS:

APPLICATION

EMPX barrel assemblies include pilot lights, pushbutton switches, illuminated pushbutton 

switches, selector switches and combinations.  They are used in control stations, panels 

and enclosures used in areas made hazardous due to the presence of flammable vapors, 

gases or combustible dusts.

IMPORTANT NOTE

When EMPX devices are to be installed in Crouse-Hinds equipment, refer to Installation 

Instruction Sheet that came with that equipment for proper installation.

IF 1857 • 09/18 

           Copyright © 2018, Eaton’s Crouse-Hinds Division 

Page 1

PILOT LIGHTS:

NOTE: 

Verify that LED marked rating matches the socket before replacement.

ROTARY SWITCHES:

Rated voltage

U

i

 500V

Rated current

I

th

 10A

Breaking capacity for AC 15

Voltage

220V

380V

500V

Current

10A

7.5A

5A

Breaking capacity for DC 13

Voltage

24V

60V

110V

220V

Current

2.75A

1.10A

0.55A

0.27A

CONTACT BLOCK INFORMATION

Rated voltage

U

i

 500V

Rated current

I

th

 6A

Contacts for AC 15

Voltage

250V

Current

6A

Contacts for DC 13

Voltage

24 VDC

Current

3A

12V / 24V / 120V

Rated voltage: 250 VAC/VDC
Maximum power: 2.6W

240 VAC

Rated voltage: 240 VAC
Maximum power: 2.6W

480 VAC

Rated voltage: 480 VAC
Maximum power: 2.6W

LED SOCKET

UL application details:

Identification: 

 

 

Class I, Division 1, Groups B, C, D

 

 

 

 

Class II, Division 1, Groups E, F, G

    Class 

III

Certificate: 

 

   E10593

Ambient temperature range: 

 

-50°C to +60°C

Thread: 

 

 

 

3/4” x 14 NPSM

Required threads (Class I): 

 

Eight (8) full threads engaged

Required threads (Class II and III):  T 

Three (3) full threads engaged

Ingress protection: 

 

 

Type 4X

Storage temperature in original packaging: 

-20°C to +50°C 

IECEx and ATEX application details:

Identification: 

 

      

     II 2G Ex db IIC Gb

 

            

 

      

     II 2D Ex tb IIIC Db

Certificates: 

 

 

Sira 18ATEX1236U 

IECEx CSA 18.0027U

Ambient temperature range: 

 

-50°C to +60°C

Thread: 

 

 

 

3/4” x 14 NPSM

Required threads (EN 60079 1):   

Five (5) threads engaged (3/4“ NPSM)

Required threads (EN 60079 31):   

3.7mm (3/4” NPSM)

Ingress Protection:                           

IP66W (salt spray)

Storage temperature in original packaging:    -20°C to +50°C

APPLICABLE STANDARDS

• 

UL1203 Standard for Explosionproof and Dust-ignitionproof Electrical Equipment for 

use in Hazardous (Classified) Locations

• 

UL50 Enclosures for Electrical Equipment

• 

UL508 Standard for Industrial Control Equipment

• 

CSA C22.2 No. 25-1966 Enclosures for use in Class II, Groups E, F, G Hazardous 

Locations

• 

CSA C22.2 No. 30-M1986 Explosionproof Enclosures for use in Class I Hazardous 

Locations

• 

CSA C22.2 No. 94-M91 Special Purpose Enclosures Industrial Products

• 

CSA C22.2 No. 14-13 Industrial Control Equipment

• 

EN 60079-1 / IEC 60079-1

• 

EN 60079-31 / IEC 60079-31

Breaking capacity 

for AC

Rated current 

20A

AC-3

220-240V

3.0 kW

380-440V

5.5 kW

AC-15

220-240V

5A

380-440V

4A

AC-22A

220-240V

20A

380-440V

20A

AC-23A

220-240V

3.7 kW

380-440V

7.5 kW

Breaking capacity for 

DC

Rated 

current 20A

24V

48V

60V

110V

Resistive 

loads 

T<1ms

20A

12A

4.5A

1A

Inductive 

loads 

T=50ms

12A

2A

1A

0.4A

Rated voltage

690V

Rated current

20A

Max. no. contact 

chambers

6

Reviews: