background image

9479-ET(G)-CSL

 

CSL Intrinsically Safe Gigabit 

Ethernet WLAN AP / Bridge

March 2021
INM 9479-ET(G)-CSL Rev 1

Instruction manual

MTL Industrial Network Solutions

Summary of Contents for 9479-ETG-CSL

Page 1: ...9479 ET G CSL CSL Intrinsically Safe Gigabit Ethernet WLAN AP Bridge March 2021 INM 9479 ET G CSL Rev 1 Instruction manual MTL Industrial Network Solutions...

Page 2: ...CLARATION OF CONFORMITY A printed version of the Declaration of Conformity has been provided separately within the original shipment of goods However you can find a copy of the latest version at http...

Page 3: ...AL 4 7 WASTE REMOVAL INFORMATION 4 8 INSTALLATION 5 9 ATEX IECEx CERTIFICATION INFORMATION 6 10 SPECIFICATION 8 11 APPROVALS 9 12 NETWORK SETUP 10 12 1 Network Configuration 10 13 WI_FI SETUP 12 14 DH...

Page 4: ...assemblies may not be used in explosion hazard area applications if they have been used previously in general electrical installations WARNING The responsibility for planning installation commissioni...

Page 5: ...ia IIC T4 Ga Ex ia ia Da IIIC T135 C Db non mining Ex ia I Ma M1 mining ET version Ta 40 C to 70 C Zone 1 Zone 21 mounting Zone 0 Zone 20 with a suitable Ex ia Power Supply Note PoEx is a simple adap...

Page 6: ...net connections these can allow daisy chaining of units together Power 12V DC is supplied to the module either locally or using Power over Ethernet PoEx from the LAN port This requires the PoEx output...

Page 7: ...unction Gigabit Function 1 Tx BI_DA 2 Tx BI_DA 3 Rx BI_DB 4 PoEx 12V BI_DC 5 PoEx 12V BI_DC 6 Rx BI_DB 7 PoEx 0V BI_DD 8 PoEx 0V BI_DD Note PoEx only on LAN1 2 ports when 10 100 ET version only PoEx n...

Page 8: ...C Bulkhead Socket SMA Plug length 1000mm RG316 Cable Assembly 5 DIMENSIONS Width 42mm Height 160mm Depth 140mm Weight 1500g Mounting Din Rail 6 ENVIRONMENTAL Operating Temperature 40 C 70 C Storage Te...

Page 9: ...1 to the main power supply pins Con1 see connections section As the 9479 supports Auto MDI MDI X a straight connected RJ45 Cat5e cable is used to connect to any device It is recommended that Cat5e cab...

Page 10: ...1 and EN 60079 26 Installation a Reference to the IEC code of practice IEC 60079 14 In addition particular industries or end users may have specific requirements relating to the safety of their instal...

Page 11: ...3 For Group III the module shall be mounted inside a suitably certified enclosure which provides a minimum degree of protection of at least IP54 The module shall be installed in a manner that does not...

Page 12: ...put 802 11n 2 4GHz 18 to 20 5 dBm 5GHz 15 to 18 dBm per antenna output in 2T 2R mode RX Sensitivity 802 11n 2 4GHz 92 to 73 dBm 5GHz 96 to 72 dBm Data Rates 802 11n up to 300Mbps 2T 2R 802 11a h 6 to...

Page 13: ...IICT4 hazardous area 9479 ET Certification Code Ex ia IIBT4 Ga 9479 ETG Ex ia IICT4 Ga 9479 ET Ex ia ia Da IIIC T135 C Db non mining Ex ia I Ma M1 mining Ta 40 C to 70 C Certificate numbers ATEX CML 1...

Page 14: ...ADD NETWORK button to create a new IP network Click the REMOVE button under the action heading to remove the selected network Click the EDIT button under the action heading to open the network configu...

Page 15: ...the local area network DNS Server s The IP addresses of the DNS server s you want to use If you selected the DHCP protocol you can choose to use the value defined in the menu TOOLS System or you can...

Page 16: ...figure the wireless network settings by default the radio will be disabled and you will need to turn in on Country The regulation rules of the selected country will determine the channels and transmis...

Page 17: ...ferent frequency ranges HT high throughput mode In HT mode you can aggregate adjacent channels 2 in 802 11n 2 or 4 in 802 11ac in order to increase bandwidth One of the channels is the one selected in...

Page 18: ...nd selecting All for this option Both are also required for 802 11n MIMO mode For single antenna use select Only 1 and connect the antenna to the AUX socket however performance will be reduced with a...

Page 19: ...nning will not real this SSID on the AP Network This option allows selecting the network where the interface is added Mesh ID only in mess mode This option replaces the ESSID when the Mesh mode is sel...

Page 20: ...ace DHCP pool first address if enabled First IP Address of the DHCP pool This is interpreted as an offset relative to network address DHCP pool size if enabled Maximum number of leased addresses Lease...

Page 21: ...he network If this option is checked the DHCP server wont check for another server before start IPv4 Netmask This option override the default netmask value sent to DHCP clients DHCP Options This field...

Page 22: ...vice Information page allows a quick overview of the unit s useful information and the currently installed firmware information 15 2 Network Interfaces This Page shows a summary of the currently confi...

Page 23: ...e number of bytes of transmission and reception on the interface Packets graph Displays the number of processed dropped and error packets of transmission and reception on the interface Broadcast Multi...

Page 24: ...the setup Network Page Subnet The subnet that this interface connects to and the number of subnet bits Threshold Minimum TTL required to forward data to this interface EN Multicasting is enabled on t...

Page 25: ...erface toward the RP where data comes in Multicast Group The block of groups associated to this RP Priority Priority of the RP for elections Locally configured groups have a priority of 1 Hold Time Th...

Page 26: ...ges will be left unchanged 19 Password These Pages allow you to change the Password on both the Root and the user accounts On initial power up both passwords are set empty this will allow you to enter...

Page 27: ...This allows you to set the time zone you are in Device Location This is a user definable device location field Server name If there is a NTP server reachable on the network the unit can use it to con...

Page 28: ...g This log displays a summary of the units configuration Kernal Log This log displays messages from the Linux kernel only System Log This log displays messages from both the kernel and from the runnin...

Page 29: ...IP Address and UDP port where the log messages will be sent using the syslog protocol Leave empty to disable Log Settings These sections are used to configure logging for various services the message...

Page 30: ...s to a file You are then able to restore the previously saved file back into the unit This will load up all of its previous settings Reset Clicking this button will restore its factory default setting...

Page 31: ...27 INM 9479 ET G CSL Rev 1 This page is left intentionally blank...

Page 32: ...Off Old Mahabalipuram Road Sholinganallur Chennai 600 119 India Tel 91 0 44 24501660 24501857 Fax 91 0 44 24501463 E mail mtlindiasales eaton com ITALY MTL Italia srl Via San Bovio 3 20090 Segrate Mil...