Page 1: ...Dragonfly Energy Battle Born Batteries Dragonfly Energy Corp Phone 855 292 2831 Email info battlebornbatteries com Model BB1275 Group 24 12V 75Ah Deep Cycle LiFePO4 Battery Manual and Installation Guide ...

Page 2: ...y Charge the Batteries 5 How to Properly Size Cables for a System Install 6 How to Incorporate Fuses Into System Install QR for Blog 7 How to Properly Store Batteries QR for Blog 7 How to Maintenance the Batteries 7 Warranty 7 Return Policy 8 Refund Policy 8 Shipping 8 How to Properly Recycle and Dispose of the Batteries 7 QR Codes will appear throughout the manual linking to FAQ videos that may b...

Page 3: ...and negative terminals These are labeled and color coded red for positive black for negative 2 Determine which finishing hardware set you will use Verify that your bolt can fully seat into the nylok insert of the nut If multiple lugs are used longer bolts may be required for the bolt to fully seat into the nylok insert of the nut 3 Connect your cable lugs to your battery terminal with the previous...

Page 4: ... and color coded red for positive black for negative 2 Determine the appropriate finishing hardware set you will use Verify that your bolt can fully seat into the nylok insert of the nut If multiple lugs are used longer bolts may be required for the bolt to fully seat into the nylok insert of the nut 3 Make the proper cable connections to the positive of the first battery Please reference Fig 1 fo...

Page 5: ...ng to your battery terminals DO NOT finger tighten Use a torque wrench to torque your hardware to the specification of 9 to 11 ft lbs Failure to adequately secure connections can result in severe damage and will void your warranty 6 Connect the other end of your cable to the positive terminal of the other battery you are connecting to Repeat step 4 7 Repeat steps 3 6 for additional batteries but D...

Page 6: ...Temperature Charging 25 F 3 9 C The BMS will not allow a charging current under 25 F 3 9 C but will continue to discharge down to 4 F 20 C NOTE The BB1275 has an operating temperature range of 4 F 20 C to 135 F 57 2 C High Current Discharge Surges The BMS will not allow a current that exceeds 200 5 Amps for more than 30s or anything larger for 0 5s After a high current disconnection the battery wi...

Page 7: ...e Battle Born batteries to a 100 state of charge Then disconnect the battery from any loads by removing the negative cable from one battery On average the batteries lose approximately 2 3 capacity per month This is subject to increasing if stored in extreme environmental conditions How to Maintain the Batteries Battle Born Batteries require very little maintenance If your batteries are in series a...

Page 8: ...al packaging Original packaging must be in the same condition as it was received otherwise you may be responsible for a restocking fee If the item has been installed used or no longer has the original packaging we will assess a restocking fee that will be shared when the return merchandise authorization RMA is issued Items 60 days past the original invoice will be reviewed at Battle Born s discret...