Instruction Manual 

 

# FJ4B 8800 lb. CAPACITY  

FORKLIFT JACK 

 

 

 
                                             
     
      

                                                 

CAPACITY

4000kgs  

 
 

NOTE:

 

Owner / Operator must read and 

understand this instruction manual 
 before using the forklift jack. 

             

              
 
   

NOTE: 

IT IS THE OWNER/OPERATOR

’S  

   RESPONSIBILITY TO READ AND UNDERSTAND 

THIS INSTRUCTION MANUAL BEFORE USING 

THESE FORKLIFT JACKS. FAILURE TO DO SO  

MAY CAUSE SERIOUS INJURY. 

 

Summary of Contents for FJ4B

Page 1: ...s NOTE Owner Operator must read and understand this instruction manual before using the forklift jack NOTE IT IS THE OWNER OPERATOR S RESPONSIBILITY TO READ AND UNDERSTAND THIS INSTRUCTION MANUAL BEFORE USING THESE FORKLIFT JACKS FAILURE TO DO SO MAY CAUSE SERIOUS INJURY ...

Page 2: ...NTS 1 SPECIFICATIONS 2 2 IMPORTANT 2 3 FEATURES 3 4 OPERATING INSTRUCTIONS 4 5 SAFETY TIPS 7 6 MAINTENANCE INSTRUCTIONS 10 7 PUMP PRRMING INSTRUCTIONS 10 8 PLACARD PARTS LIST 11 9 PARTS LIST EXPLODED FIGURE 12 ...

Page 3: ... equipment Before using the jack you must read and understand all the instructions warnings and precautions contained in this manual as well those affixed to the jack in the form of decals 2 Warning symbol This symbol is used to warn you of specific situations which may occur and must be avoided when using the FJ4B jack Failure to observe these warnings may result in personal injury and or propert...

Page 4: ...ar inspection should be made weekly for daily use and monthly for intermittent use Damaged jacks any jack which appears to be damaged in any way or deemed badly worm or operates abnormally MUST BE REMOVED FROM SERVICE UNTIL NECESSARY REPAIRS ARE MADE 5 You must retain this manual and make it available to all persons in need of the information contained herein 6 For additional copies please contact...

Page 5: ...t arm Fig 1 B To accomplish this it is advisable to attach a steel bar to the lower surface capable of supporting the load The serrated pad can be used to raise a vehicle with flat underside See Fig 1 A flat surface must be parallel to the floor before lifting 4 Always position lift pad least 76mm inward toward the center of vehicle from the beginning of the flat surface See Fig 1 A Never push jac...

Page 6: ...lifting 3 wheeled lift trucks never lift the 2 wheeled end WARNING Do not lift from the end of the fork lift if the contact surface is sloped or rounded See Fig 4 WARNING This is a lifting device only After lifting load must be immediately supported by adequate stands Failure to do so may result in personal injury and or property damage Fig 3 Fig 4 ...

Page 7: ...the notch at the end of the lifting arm as the lifting contact Do not attempt to use any other part of the FJ4B lack as a lifting contact point 7 Raise a fork lift with the FJ4B only when a The forks are in a lowered position b There is no load of any kind on the forks c There are no personnel on the jacks 8 If the fork lift truck is to be lifted lowered and re lifted the following procedure is to...

Page 8: ...k However 2 wheels of the lift truck must remain firmly on the floor 3 Use extreme caution when lifting narrow fork lift trucks less than 1016mm Wide from the sides Always make sure that the height between the floor and the bottom of the raised tire is never more than one fourth 1 4th of the vehicle s tread width See Fig 6 Tread width is measured from center line to center line of the tire treads ...

Page 9: ...st one inch clearance between the body of the jack and the fork lift in its raise position Failure to observe these instructions could result in damage to the FJ4B and or loss of load 7 Do not use any kind of cribbing under the FJ4B or on top of the lift pad area The jack must always remain in direct contact with the floor and the lifting pad or notch must be in direct contact with the fork lift 8...

Page 10: ...s are in place and are supporting the fork lift truck remove the FJ4B from the working area before beginning work Fig 9 12 The FJ4B jack is designed solely for the lifting of fork lift trucks Use of the jack for any other purpose constitutes misuse of the jack Users of the jack hereby warned of this misuse which can result in physical injury and or property damage 13 Damaged jacks Any jack which a...

Page 11: ...obile DTE 13 hydraulic oil to reservoir until fluid runs out the fill plug hole Do not use brake fluid Extreme care should be taken to fill plug the fluid contaminant free and keep dirt and contaminants out of the reservoir of the jack Reinstall fill plug PUMP PRIMING INSTRUCTIONS To prime the model FJ4B actuator in the event that it inadvertently becomes unprimed proceed as follows 1 Open release...

Page 12: ...RIPTION NO REQ D 1 Warning Label Use Stands to Support Vehicle 1 2 Jack Position Plate 1 3 Lift Pad Instructions 1 4 Identification Piacard FJ4B 1 5 Warning Label Do Not Adjust 1 WARNING 1 2 NOTICE 4 HFJ 400 3 TWO POSITION LIFT PAD WARNING 5 ...

Page 13: ...UT 2 FJ4B 52 RELEASE ROD 1 FJ4B 15 SPACER 2 FJ4B 53 RELEASE KNOB 1 FJ4B 16 PIN 1 FJ4B 54 PIN 1 FJ4B 17 SADDLE 1 FJ4B 55 CHAIN HOOK 1 FJ4B 18 PIN 1 FJ4B 56 CHAIN HOOK 1 FJ4B 20 SCREW 2 FJ4B 57 HANDLE BASE 1 FJ4B 21 SEAL RING 2 FJ4B 58 RING 1 FJ4B 23 SPRING 1 FJ4B 59 PIN 1 FJ4B 24 BALL SEAT 1 FJ4B 60 HANDLE 1 FJ4B 25 BALL SEAT 1 FJ4B 61 GRIP 1 FJ4B 26 VALVE BLOCK 1 FJ4B 62 PIN 1 FJ4B 27 MAGNET STEEL...

Page 14: ...13 ...

Page 15: ......