699 Keypad Deskstand

Description

The 699 Keypad Deskstand is a mounting stand configured for all DMP LCD keypad models. The 699 is constructed 

of smoked plexiglass or metal and provides a sturdy keypad mounting option for any location. Designed to provide 

access to all DMP keypad wiring headers allows quick and easy keypad wire connections.

What is Included

•  699 Keypad Deskstand
•  Wiring Block
•  Wire Harness 4 ft.
•  Four round head self-tapping Phillips mounting screws

Note

: When using the 7760 Clear Touch Keypad a 778 Keypad Backplate is needed to enhance the keypad display.

Mounting Keypads

Standard Keypad Mounting

Use the round head self-tapping Phillips screws to mount the keypad base to the 699 Deskstand. Refer to Figure 1 as 

needed.

1. Refer to the keypad installation guide and remove the cover from the keypad base.
2. Align the keypad base to the four keypad mounting holes on the 699 Deskstand.
3. Insert the screws through the keypad base and 699 Deskstand.
4. Use a Phillips head screwdriver to tighten the four screws into place. Do not overtighten.
5. Replace the keypad cover.

Wire Harness wire tie 

strain relief mounting 

holes located in 

Deskstand base.

Premounted feet (4 places)

Deskstand Front View

Deskstand Side View

Thin Keypad 

on 699 Deskstand

Optional Wire 

Harness wire 

tie strain relief 

mounting hole.

690 and 790 Series

Keypad mounting holes.

Use self-tapping Phillips 

head screws.

Keypad wiring

harness

openings

Clear Touch 

Keypad

mounting hole.

Clear

Touch

Keypad

mounting

hole.

Clear Touch Keypad wiring harness opening.

778 Backplate flush mounting holes.

778 Backplate flush mounting holes.

Figure 1: 699 Keypad Deskstand

InstallatIon GuIde

Summary of Contents for 699

Page 1: ...1 as needed 1 Refer to the keypad installation guide and remove the cover from the keypad base 2 Align the keypad base to the four keypad mounting holes on the 699 Deskstand 3 Insert the screws through the keypad base and 699 Deskstand 4 Use a Phillips head screwdriver to tighten the four screws into place Do not overtighten 5 Replace the keypad cover Wire Harness wire tie strain relief mounting h...

Page 2: ... Premounted feet 4 places Clear Touch Keypad wiring harness opening 778 Backplate 778 Backplate side view Deskstand and 778 Backplate Front View Deskstand and 778 Backplate Side View Clear Touch Keypad mounting hole Flush mounting holes Wire Harness wire tie strain relief mounting holes located in Deskstand base Figure 2 699 Keypad Deskstand with 778 Backplate Installed Wiring Panel to Wiring Bloc...

Page 3: ... 5 shows the 699 Backplate rear view with the 4 wire connector plugged into the 4 pin header Run a tie wrap through the back or base of the 699 Deskstand Roll the excess length of the 4 ft Wire Harness into a loop and use the tie wrap to hold it in place Wire Harness with wire tie strain relief in place 4 wire connector plugged into keypad 4 pin header Deskstand Rear View RED To Wiring Block Optio...

Page 4: ... not exceed 1 000 feet Install an additional power supply to increase the wire length or add devices 2 Maximum distance for any one circuit length of wire is 2 500 feet regardless of the wire gauge This distance can be in the form of one long wire run or multiple branches with all wiring totaling no more than 2 500 feet As wire distance from the panel increases DC voltage on the wire decreases 3 M...

Reviews: