background image

 

 

W

W

R

R

4

4

4

4

 

 

4000 Series Routers 

 
 

 

 
 
 
 
 

Installation Guide 

 

Summary of Contents for TransPort WR44

Page 1: ...W W R R 4 4 4 4 4000 Series Routers Installation Guide ...

Page 2: ...WEEE Waste Electrical and Electronic Equipment 2002 96 EC directive has been introduced to ensure that electrical electronic products are recycled using the best available recovery techniques to minimise the impact on the environment This product contains high quality materials and components which can be recycled At the end of its life this product MUST NOT be mixed with other commercial waste fo...

Page 3: ...the unit cause interference or create an electric shock hazard and will void your warranty 4 Do not attempt to repair the product The unit contains no electronic components that can be serviced or replaced by the user Any attempt to service or repair the unit by the user will void the product warranty 5 Products in the WR44 range are designed for indoor use only and should be used in an environmen...

Page 4: ...about potential danger contact the physician or the manufacturer of the device to verify that the equipment is properly shielded Pacemaker patients are advised to keep the wireless router away from the pacemaker while it is on Wireless routers must NOT be operated on aircraft The operation of wireless appliances in an aircraft is forbidden to prevent interference with communications systems Failur...

Page 5: ...ional Wireless LAN interface All models may also be purchased with one of a number of hardware options which are listed in the section entitled Optional Features below Package Contents When you receive the router carefully unpack it and check the contents These should include WR44 system unit 12V DC 1 5A mains adapter 100V 230VAC 50 60Hz 0 6A max this Installation Guide 1 x 2M CAT5 STP Shielded Tw...

Page 6: ...e wired networks PSTN ISDN etc to wireless operation 1 1 Front Panel Features The front panel of the unit incorporates the USB host connector 13 LED indicators and the two SIM card holders as shown in the following illustration USB Host Connector The USB host connector may be used to connect compatible USB 2 0 client devices such as memory sticks serial adapters etc Note that the total current ava...

Page 7: ... 1 LED illuminated 112 dBm and 87 dBm weak 2 LED s illuminated 86 dBm and 71 dBm medium 3 LED s illuminated 70 dBm and 51 dBm strong For the WR44 C the signal strengths are as follows None illuminated 116 dBm effectively no signal 1 LED illuminated 115 dBm and 104 dBm weak 2 LED s illuminated 103 dBm and 94 dBm medium 3 LED s illuminated 93 dBm and 83 dBm strong SIM Sockets The two sockets at the ...

Page 8: ...programmable IO signal lines ASY 0 This 9 way D socket provides an asynchronous RS232 serial port which may be used to connect the router to a compatible serial device ANT WWAN Main This SMA connector is used to fit the wireless antenna The WR44 E model are supplied with a single stub antenna which should be fitted to this connector The WR44 U model both support diversity antenna capability to imp...

Page 9: ...ished booting will cause the factory settings to be loaded into flash before and then re boot During this time you will see a pattern of alternating LEDs flashing followed by the normal boot sequence Do not remove power from the unit during this operation as corruption of the flash memory may occur 1 3 Optional features WR44 series routers are available with a variety of hardware options At presen...

Page 10: ...tion Guide 9 Only one of the above options can be fitted and will occupy the area of the rear panel normally covered with the blanking plate For example if the GPS option is fitted the rear panel will appear as shown below ...

Page 11: ...ssible signal reception Digi International can supply a range of suitable antennas Step 1 Installing the SIM card s The router incorporates two separate SIM card holders so that if your application demands it you may install SIMs for two different networks This means that one wireless service may be used as a back up service in the event that the primary service fails in some way By default SIM 1 ...

Page 12: ...nas These should be screwed onto the male SMA connectors labelled ANT WLAN Main and ANT WLAN Aux Step 4 Connecting the LAN cable Plug one end of one of the supplied 2 metre CAT5 STP cable into the RJ45 socket labelled LAN 0 Plug the other end into the LAN socket on your PC or notebook Step 5 Connecting the serial cable For connection to a serial terminal device a 9 way D type serial cable is requi...

Page 13: ...figuration menu on the left hand side of the home page There are also a number of configuration wizards which can be accessed via the Wizards menu on the left hand side of the home page These will step you through various types of configuration Please refer to the Digi Transport User Guide for information on the various configuration parameters The User Guide can be downloaded from the Digi websit...

Page 14: ... router s firewall has not been enabled 2 PC IP configuration The PC s LAN interface that is connected to the router should be configured to Obtain an IP address automatically If required the Digi Transport Connection Wizard can be used to configure the PC 3 Check the PC s LAN connection and any LAN device e g Ethernet switch that is used to interconnect to the router 4 ARP resolution Try clearing...

Page 15: ...nal lines One is an input line the other can be configured as either an input line or an output line The mode of operation of the input output line is configurable through the CLI The signal lines can be wired as shown in the following diagrams 2 Inputs Supply Voltages up to 28V DC 2 Inputs Supply Voltages up to 58V DC ...

Page 16: ...put 1 Output Supply Voltages up to 58V DC If the auxilary power connector is being used the main power connector should NOT be used A fused power cable P N 76000774 can be purchased separately from Digi International The fuse that is supplied with the cable is a 2A 250V quick blow fuse ...

Page 17: ...t Signal Information 1 Maximum voltage switched 28V DC 2 Maximum current switched 40mA 5 Output protection activates at more than 28V DC External current limiting is needed to protect input voltages above 28V DC 3 Output leakage current is equivalent to a 10 Kohms resistor to Ground 4 Suggested minimum Relay Coil resistances a Supply Voltage 6V DC minimum resistance 100 Ohms b Supply Voltage 12V D...

Page 18: ... 10 mobile station class B PBCCH support coding schemes CS 1 4 WR44 U GSM GPRS EDGE UMTS HSDPA HSUPA modem HSUPA mode 2 Mbps Category 5 HSDPA 1 8 Categories 1 4 11 and 12 HSDPA 3 6 Categories 5 and 6 HSDPA 7 2 Categories 7 and 8 UMTS 384 Kbps downlink 384 Kbps uplink MO 0301 850 1900 2100 Rx diversity MHz MO 0302 850 Rx Diversity 1900 Rx Diversity 2100 MHz Equalization and Rx Diversity at the same...

Page 19: ...X WE1 SW WR44 E1XX DE1 SW where XX can be 00 A1 A3 G1 I1 S1 T1 conform to the relevant harmonised standards EN60950 1 2006 EN55022 2006 A1 2007 EN55024 1998 A1 2001 A2 2003 EN61000 3 2 2006 EN61000 3 3 1995 A1 2001 A2 2005 EN301489 7 v1 2 1 EN301489 17 v2 1 1 following the provisions of Council Directive 2004 108 EC on radio equipment and telecommunications terminal equipment and the mutual recogn...

Page 20: ...WR44 Series Installation Guide 19 ...

Reviews: