background image

BEETLE M1350

Operator Manual

01750349439 B

Public

This document is property of Diebold Nixdorf and is intended for customer use. A written license

agreement with Diebold Nixdorf is not required to use this material.

Summary of Contents for BEETLE M1350

Page 1: ...M1350 Operator Manual 01750349439 B Public This document is property of Diebold Nixdorf and is intended for customer use A written license agreement with Diebold Nixdorf is not required to use this ma...

Page 2: ...should be treated as confidential material for security reasons Any unauthorized disclosure or use of confidential material may violate the U S Theft of Trade Secrets provisions of Section 1832 of Ti...

Page 3: ...1 Document History Material Number Date Remarks 01750349439 A 12 2021 Original edition including TSE description 01750349439 B 02 2022 Corrected TSE function Copyright 2022 Diebold Nixdorf 01750349439...

Page 4: ...onnecting Disconnecting Cables 5 1 6 Storage Media 6 1 6 1 Replacement of Solid State Disk SSD 6 2 6 2 Replacement of the RAM 6 3 7 Technical Security Device TSE 7 1 8 Installation 8 1 8 1 The Tools Y...

Page 5: ...6 1 Removing the screws from the housing 6 1 Figure 6 2 Removing the cover upwards 6 1 Figure 6 3 Removing the SSD 6 2 Figure 6 4 Replacing the SSD 6 2 Figure 6 5 Removing the RAM 6 3 Figure 6 6 Repla...

Page 6: ...nt History iii Table 1 1 Warning signs used 1 2 Table 4 1 Front Panel Functions 4 3 Table 12 1 Technical Data BEETLE M1350 12 1 Table 12 2 AC Power Adapter 12 2 Table 12 3 Total available power 12 3 C...

Page 7: ...table of contents will help you find the desired information quickly and eas ily WARNING This symbol is used for warnings NOTE Notes in this manual are marked by this symbol The type and scope of appl...

Page 8: ...he following designations can be used in this manual or on the device Table 1 1 Warning signs used Warning signs General information Warning signs Warning of electrical voltage Warning of hot surface...

Page 9: ...Risk of fatal injury through contact with parts carrying electrical voltage Switch the sys tem off before performing any cleaning or maintenance tasks l Switch off the power switch for the power dist...

Page 10: ...tistatic kit Statically discharge yourself for example by touching an earthed object such as a heat radiator be fore beginning to work with ESD labelled components Likewise all equipment and tools use...

Page 11: ...ptions with configurable memory and SSD options Processor Type Whiskey Lake 15W Processor Options Celeron 4305UE Core i3 8145UE Core i5 8365UE Memory Options DDR4 1866 2133 2400 MT s SODIMM up to 32 G...

Page 12: ...4 4 Overview 4 1 4 1 ID Plates and Serial Numbers Figure 4 1 Position of plates 1 FCC plate 2 Type plate 3 Service plate Copyright 2022 Diebold Nixdorf 01750349439 B 4 1...

Page 13: ...Overview Figure 4 2 Type plate Example for type plate Figure 4 3 Service plate Example for service plate Figure 4 4 FCC plate Example for FCC plate Copyright 2022 Diebold Nixdorf 01750349439 B 4 2...

Page 14: ...wer LED lights orange when the system has been shut down and is in power mode S5 During shutdown it takes a few seconds before the color change occurs The Power LED lights green when the system is on...

Page 15: ...ack View Figure 4 6 BEETLE M1350 Back View 1 LAN 2 COM 1 3 COM 2 4 USB 2 0 5 USB 3 1 6 Power in DC 24V 7 Cash drawer 8 USB type C PD 5 12 24V DP 9 USB type C PD 5 12V DP Copyright 2022 Diebold Nixdorf...

Page 16: ...to hot surface The device heats up during operation Touching the hot surface can cause burns l Wait until the surface has cooled down l Wear protective gloves Figure 4 7 BEETLE M1350 Top View 1 Heat S...

Page 17: ...Overview 4 5 4 5 Inside View Figure 4 8 BEETLE M1350 Inside View 1 SODIMM socket 2 M 2 2280 socket 3 M 2 2280 socket Copyright 2022 Diebold Nixdorf 01750349439 B 4 6...

Page 18: ...wer adapter 1 DC power out 2 Power indicator 3 AC power adapter 4 AC power plug The external power supply is applicable for common line voltage It automatically adjusts itself to the particular voltag...

Page 19: ...lug a cable by pulling on the cable always take direct hold of the plug itself Follow the proce dure below when disconnecting cables Turn off all power and equipment switches Remove the cable cover Un...

Page 20: ...s in serted until released Pull the plastic covering from the connecting socket with your thumb The lock is released The metal of the plug is visible Figure 5 3 RJ plug RJ plugs lock in place when plu...

Page 21: ...Disconnecting Cables Figure 5 4 USB plug USB plugs that are not supplied with power do not latch in place when plugged in and can be unplugged with a gentle pull Copyright 2022 Diebold Nixdorf 0175034...

Page 22: ...ses memory elements in place of a rotating disk to store data The SSD easily substitutes the hard disk and emulates a hard disk drive interface Most SSDs are flash memory based Figure 6 1 Removing the...

Page 23: ...e present depending on your system configuration Figure 6 3 Removing the SSD 2 Remove the screw on the SSD 1 3 The SSD can now be removed from their slots by pulling downwards in the direction indi ca...

Page 24: ...step below Figure 6 5 Removing the RAM 3 To unhook the RAM locate the 2 latches 1 by their sides 4 Press them in an outwards direction 2 5 The RAM is now unhooked and can be re moved and replaced Fig...

Page 25: ...ichtlinien f r Sicherheitseinrichtungen von elektronischen Aufzeichnungssys temen From 1st of January 2020 POS manufacturers will be obliged to deliver each POS within Germany with the functionality o...

Page 26: ...2 Unlocking the cover 2 Gently slide cover to unlock 1 3 Flip open the cover 2 Figure 7 3 Inserting the SD card 4 Insert the SD card 3 5 Close the cover 4 6 Gently slide the cover to lock 5 Copyright...

Page 27: ...Device TSE Figure 7 4 Pre assembling the TSE module 7 Mount the bracket to the TSE module 1 Figure 7 5 Inserting the TSE module 8 Insert the TSE module into the BEETLE 1 Copyright 2022 Diebold Nixdorf...

Page 28: ...Technical Security Device TSE Figure 7 6 Fixing the TSE module 9 Tighten the screw 1 to fix the TSE module Copyright 2022 Diebold Nixdorf 01750349439 B 7 4...

Page 29: ...1 8 1 The Tools You Need Make sure you have the following tools available before beginning work on the BEETLE M1350 Phillips screwdrivers PH0 Torx screwdriver Torx TX10 Copyright 2022 Diebold Nixdorf...

Page 30: ...change The system must not be oper ated in a closed cabinet or drawer Figure 8 1 Mounting Options 1 Device freestanding 60 mm free space surrounding 2 Wall installation Power Button downwards 60 mm fr...

Page 31: ...Use only Diebold Nixdorf wall mount plate Figure 8 2 Mounting the back plate 1 Use the recommended fasteners not sup plied to attach the wall mount back plate onto the concrete wall 2 Ensure that the...

Page 32: ...Installation Figure 8 4 Fixing the device 4 Tighten the thumb screw on the bottom of the back plate to secure the device Copyright 2022 Diebold Nixdorf 01750349439 B 8 4...

Page 33: ...9 9 Replacement of the Lithium Battery NOTE The lithium battery may only be replaced by authorized personnel l Contact your service provider Copyright 2022 Diebold Nixdorf 01750349439 B 9 1...

Page 34: ...rocessor type on the monitor DN ID xx xx Date xx xx is the placeholder of the BIOS version number Following the completion of the BIOS boot up the BIOS will attempt to boot up an operating system from...

Page 35: ...x54 Unspecified memory initialization error 0x55 Memory not installed 0x56 Invalid CPU type or Speed 0x57 CPU mismatch 0x58 CPU self test failed or possible CPU cache error 0x59 CPU micro code is not...

Page 36: ...6 No Console Output Devices are found 0xD7 No Console Input Devices are found 0xD8 Invalid password 0xD9 Error loading Boot Option LoadImage returned error 0xDA Boot Option is failed StartImage return...

Page 37: ...ative humidity 1g m3 to 25g m3 Condensation is not permitted User Accessible I O 3x USB 2 0 Type A 1x frontside 2x backside 2x USB 3 0 Type A 1x RJ12 Cash Drawer 1x RJ45 Gigabit LAN 2x RJ50 COM port p...

Page 38: ...ents and common standards Table 12 2 AC Power Adapter Rated input voltage 100 240VAC Rated input current 2 0A Input frequency range 47 63 Hz Rated output voltage 24V 5 Rated output current 5 0A Max ou...

Page 39: ...available power Part Number Model Name Output Rating Total power available External I O Ports 1750266555 ADC029 280G 120W 72W Type Port Name Voltage Current Rating Max Total Power Consumption W USB 3...

Page 40: ...s A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environme...

Page 41: ...bserve the respective national regulations with regard to the disposal of elec trical equipment Electrical equipment should not be disposed of as normal municipal waste within the EU crossed out wheel...

Page 42: ...DIEBOLD NIXDORF Incorporated 50 Executive Pkwy PO Box 2520 Hudson OH 44236 USA 2022 Diebold Nixdorf Incorporated All Rights Reserved...

Reviews: