KT8

8” TEMPERATURE CHART RECORDER

USER MANUAL & 

PRODUCT GUIDE

BATTERY COMPARTMENT

DIP SWITCHES

ADJUST BUTTONS

AC ADAPTER

REPLACEABLE
SENSOR™ PORT

REFERENCE GUIDE

REPLACEABLE SENSOR™ 
CERTIFICATE OF VALIDATION

Dickson ensures that the Replaceable Sensors™ / 
Instruments listed below were developed, tested 
and validated together.

Replaceable Sensor™ Model: R400
Instrument Model: KT6P1, KT6P2, KT6P5 

Operation:

 The Instruments and Replaceable 

Sensor™ models listed above were specifically 
designed to work together. No other sensors 
will work with the Instrument models listed. No 
other Instrument will work with the Replaceable 
Sensors™ listed. The Replaceable Sensor™ must be 
connected to the Instrument for the Instrument to 
operate properly.

Calibration: 

Only the Replaceable Sensor™ is 

calibrated. The sensor, and all calibration defaults 
and adjustments are stored on the Replaceable 
Sensor™. Accuracy is strictly controlled by 
the sensor – no adjustments are made by the 
Instrument. Readings are sent from the Replaceable 
Sensor™ to the Instrument for storage purposes 
only. Certificates of Calibration / NISTs are only 
supplied for the Replaceable Sensor™ for this 
reason. 

Recalibration:

 When a Replaceable Sensor™ is due 

for recalibration the existing Replaceable Sensor™ 
can be replaced with a new Replaceable Sensor™ 
thus eliminating the need to return the entire 
instrument for recalibration. Replaceable Sensors™ 
can be returned for recalibration as well.

Summary of Contents for KT8

Page 1: ...rument models listed No other Instrument will work with the Replaceable Sensors listed The Replaceable Sensor must be connected to the Instrument for the Instrument to operate properly Calibration Only the Replaceable Sensor is calibrated The sensor and all calibration defaults and adjustments are stored on the Replaceable Sensor Accuracy is strictly controlled by the sensor no adjustments are mad...

Page 2: ... solid green While in this state the ADJUST UP button will move the chart backward counter clockwise and the ADJUST DOWN button will move the chart forward clockwise Rotate the chart until the correct hour and day if applicable on the chart is referenced to the timing arrow Once you have set your chart press the PEN HOME button to exit Chart Adjust Mode The unit will take one minute to exit the Ch...

Page 3: ...will not turn off 2 To raise the unit of measurement press the ADJUST DOWN button To lower the unit of measurement press the ADJUST UP button Pressing PEN HOME switches between the red and blue pens on a two pen unit and stores the current adjustment value 3 When Calibration is complete press the ON OFF button The adjustment is stored in memory even after you turn the unit off or ifAC power fails ...

Page 4: ...has phase motors or compressors that cycle periodically As these other machines cycle they momentarily have a high current draw therefore drawing from the unit Whywon t the chart recorder respond to changes Is the unit locked up This can be confirmed by pressing any of the buttons on the keypad if the unit is locked up there will be no response to button presses and the unit may appear to be worki...